SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
SC551-01  | A  | Thermopile (Edge) Disconnection  | 
In Machine Condition A, after turning the fusing lamp on, the thermopile (edge) (TH2) has detected the temperature of -50°C or below continuously for 0.1 second. Machine Condition A refers to any of the following conditions: 
  | ||
  | ||
  | ||
SC551-02  | A  | Non-contact Thermistor (Edge) Disconnection  | 
In Machine Condition A, after turning the fusing lamp on, the non-contact thermistor (edge) (S47) has detected the temperature of 36°C or higher continuously for 1 second. Machine Condition A refers to any of the following conditions: 
  | ||
  | ||
  | ||
SC551-03  | A  | Non-contact Thermistor (Edge) Short-circuit  | 
In Machine Condition A, after turning the fusing lamp on, the non-contact thermistor (edge) (S47) has detected the AD value of 8 or below continuously for 1 second. Machine Condition A refers to any of the following conditions: 
  | ||
  | ||
  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
SC552-02  | A  | Thermopile (Edge) Does Not Reload  | 
In Machine Condition B, after turning the fusing lamp (edge) on, the thermopile (edge) (TH2) has failed to reach 65°C in 14 seconds. Machine Condition B refers to any of the following conditions: 
  | ||
SC552-03  | A  | Thermopile (Edge) Does Not Reload  | 
In Machine Condition B, after turning the fusing lamp (edge) on, the thermopile (edge) (TH2) has failed to reach the "permissible temperature for reloading" in 28 seconds. Machine Condition B refers to any of the following conditions: 
  | ||
SC552-05  | D  | Thermopile (Edge) Does Not Reload (Low Power)  | 
| The detection criteria is the same as that for SC552-02. | ||
SC552-06  | D  | Thermopile (Edge) Does Not Reload (Low Power)  | 
The detection criteria is the same as that for SC552-03.  | ||
  | 
  | 
  | 
  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
SC553-00  | A  | Thermopile (Edge) High Temperature Detection (software)  | 
The thermopile (edge) (TH2) has detected the temperature of 240°C or higher continuously for 1 second.  | ||
  | ||
 If the problem cannot be solved after performing the above steps, replace the fusing unit.  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
SC554-01  | A  | Thermopile (Edge) high temperature detection (hardware)  | 
In the event of an error  | ||
  | ||
 If the problem cannot be solved after performing the above steps, replace the fusing unit.  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
SC554-02  | A  | Non-contact Thermistor (Edge) high temperature detection (hardware)  | 
In the event of an error  | ||
  | ||
  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
SC555-01  | A  | Fusing Edge Lamp Continuously Heat  | 
SC555-05  | D  | Fusing Edge Lamp Continuously Heat (Low Power)  | 
  | 
  | After waiting for full power for more than 5 sec continuously. 
 
 
  | 
  | ||
  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
SC557-00  | C  | Zero Cross Frequency Exceeded  | 
In the event of an error  | ||
Frequency instability of mains power supply /Noise  | ||
-  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
SC558-01  | C  | Low Input Voltage  | 
Input voltage below the specification is detected on the mains power supply  | ||
Low input of mains power supply  | ||
-  | 
SC No.  | Type  | Error Name/Error Condition/Major Cause/Solution  | 
SC559-00  | A  | Fusing Jam Detected for 3 Times Consecutively  | 
Fusing jam (does not reach fusing exit sensor (S27)) is detected for 3 times consecutively. 
 Displays the SC559-00 at the time of integrating the counter each time fusing jam occurs, became fusing jam counter value = 3. The counter value is retained without fusing jam also reset by OFF/ON the power supply. 
 And enables ON / OFF is this SC, the default is set to OFF, then ON at the time of customer requirements. SP1-142-001 0: OFF (default), 1: ON (Set at the time of customer requirements) 
 
  | ||
  | 
  | Fusing unit paper jam | 
  |