SP 8941 (Machine Status) keeps a record of the amount of time that the machine spends in each mode.

  • 8941-001: Operating mode
  • 8941-002: Standby mode
  • 8941-003: Panel off mode (Not used in this model)
  • 8941-004: Low power mode
  • 8941-005: Sleep mode

With this data, and the power consumption values from the specifications, we can estimate the amount of energy that is used by the machine.

This should only be used as a reference value, because the power consumption specifications are measured in a controlled environment with a constant power supply.

To get an exact measurement at the customers site, a watt meter must be used to measure the actual energy consumed.

To use SP8941 to calculate the energy consumed:

  • At the start of the measurement period, read the values of SP8941 001 to 005.
  • At the end of the measurement period, read the values of SP8941 001 to 005 again.
  • Find the amount of time spent in each mode (subtract the earlier measurement from the later measurement).
  • Multiply this by the power consumption spec for each mode.
  • Convert the result to kWh (kilowatt hours)

Here is an example calculation.

Machine

Date

Power Consumption (W): Data: a

SP8941: Machine Status

Start Time: (min.) Data: b

End Time: (min.) Data: c

Time Differences (Data: b - Data: c) (min.) Data: d

Power Consumption (Data: a x Data: d) (Wmin.)

Data: e

Operating mode

NA: 543W

EU: 565W

001: Operating Time

21089

21386

21386

NA: 161271

EU: 167805

Ready mode (stand by)

51W

002: Standby Time

306163

308046

308046

96033

Energy mode (Panel off)

1W or less

003: Energy Save Time

0

0

0

0

Low power mode

20W or less

004: Low power Time

71386

71386

75111

74500

Sleep mode

1W or less

005: Off mode Time

508776

508776

520377

11601

Total Time of Data: d (min.)

17506

 

Total Time of Data: d/60min. (Hour)

291.7667

 

Total Power Consumption of Data: e (Wmin.)

NA: 343405

EU: 349939

Total Power Consumption of Data: e /60min./1000W (KWH)

NA:5.72342

EU: 5.83232