SP 8941 (Machine Status) keeps a record of the amount of time that the machine spends in each mode.
- 8941-001: Operating mode
- 8941-002: Standby mode
- 8941-003: Panel off mode (Not used in this model)
- 8941-004: Low power mode
- 8941-005: Sleep mode
With this data, and the power consumption values from the specifications, we can estimate the amount of energy that is used by the machine.
This should only be used as a reference value, because the power consumption specifications are measured in a controlled environment with a constant power supply.
To get an exact measurement at the customers site, a watt meter must be used to measure the actual energy consumed.
To use SP8941 to calculate the energy consumed:
- At the start of the measurement period, read the values of SP8941 001 to 005.
- At the end of the measurement period, read the values of SP8941 001 to 005 again.
- Find the amount of time spent in each mode (subtract the earlier measurement from the later measurement).
- Multiply this by the power consumption spec for each mode.
- Convert the result to kWh (kilowatt hours)
Here is an example calculation.
Machine Date | Power Consumption (W): Data: a | SP8941: Machine Status | Start Time: (min.) Data: b | End Time: (min.) Data: c | Time Differences (Data: b - Data: c) (min.) Data: d | Power Consumption (Data: a x Data: d) (Wmin.) Data: e |
---|---|---|---|---|---|---|
Operating mode | NA: 543W EU: 565W | 001: Operating Time | 21089 | 21386 | 21386 | NA: 161271 EU: 167805 |
Ready mode (stand by) | 51W | 002: Standby Time | 306163 | 308046 | 308046 | 96033 |
Energy mode (Panel off) | 1W or less | 003: Energy Save Time | 0 | 0 | 0 | 0 |
Low power mode | 20W or less | 004: Low power Time | 71386 | 71386 | 75111 | 74500 |
Sleep mode | 1W or less | 005: Off mode Time | 508776 | 508776 | 520377 | 11601 |
Total Time of Data: d (min.) | 17506 | |||||
Total Time of Data: d/60min. (Hour) | 291.7667 | |||||
Total Power Consumption of Data: e (Wmin.) | NA: 343405 EU: 349939 | |||||
Total Power Consumption of Data: e /60min./1000W (KWH) | NA:5.72342 EU: 5.83232 |