FU1  | Microfuse  | Overcurrent protection for Toner Supply Solenoid circuit  | Symptom - Toner is not supplied even though the remaining Toner in the Toner Cartridge is sufficient and supplying is performed.
 
 Cause - There is a short in the solenoid, or a Fuse blows caused by the GND short in the Harness.
 
 Action  | 
FU2  | Microfuse  | Overcurrent protection for Duplex Inverter Solenoid circuit  | Symptom - Duplex is not performed properly.
 
 Cause - There is a short in the solenoid, or a Fuse blows caused by the GND short in the Harness.
 
 Action  | 
FU3  | Microfuse  | Overcurrent protection for LED Power supply  | Symptom Cause - Harness (+5V_LED) is shorted to GND.
 - Fuse blows caused by the GND short in the Harness.
 
 Action - Replace the Operation Panel or EGB
 
  | 
FU4  | Microfuse  | Overcurrent protection for Operation Panel  | Symptom - The Operation Panel does not work even though the power is turned on.
 
 Cause - Harness (+5VX_OPU) is shorted to GND.
 - Fuse blows caused by the GND short in the Harness.
 
 Action - Replace the Operation Panel or EGB
 
  |