1. Execute SP3-017-001 (TnrRmnSnsFc) and SP3-017-002 (TnrRmnSnsBk).
  2. Execute the SPs below, and then check the category of the LED used for the toner-end sensor for each color.

    Toner End Sensor

    SP

    No. to be identified/LED category

    BK

    3-244-009

    29: Category 1

    31: Category 2

    27: Category 3

    C

    3-244-016

    9: Category 1

    5: Category 2

    4: Category 3

    M

    3-244-015

    21: Category 1

    20: Category 2

    16: Category 3

    Y

    3-244-014

    24: Category 1

    23: Category 2

    20: Category 3

  3. Check the output count of each color toner in the following SPs.
    • SP3-411-005: SnsOutCntAvK
    • SP3-411-006: SnsOutCntAvY
    • SP3-411-007: SnsOutCntAvM
    • SP3-411-008: SnsOutCntAvC
  4. The amount of the toner is adequate if the [SnsOutCnt] values are within the range of the following table:
    Middle-temperature, Middle-humidity conditions (23C 50%)

    LED Category

    Category 1

    Category 2

    Category 3

     

    Min.

    Max.

    Min.

    Max.

    Min.

    Max.

    Bk

    12

    30

    15

    30

    12

    27

    C

    9

    30

    5

    29

    4

    30

    M

    21

    30

    20

    31

    16

    25

    Y

    24

    37

    23

    37

    20

    37

    High-temperature, High-humidity conditions (27C 80%)

    LED Category

    Category 1

    Category 2

    Category 3

     

    Min.

    Max.

    Min.

    Max.

    Min.

    Max.

    Bk

    10

    29

    10

    31

    10

    27

    C

    16

    37

    20

    37

    20

    37

    M

    20

    37

    15

    30

    14

    28

    Y

    26

    37

    20

    37

    16

    37

    Low-temperature, Low-humidity conditions (10C 15%)

    LED Category

    Category 1

    Category 2

    Category 3

     

    Min.

    Max.

    Min.

    Max.

    Min..

    Max.

    Bk

    14

    34

    14

    34

    14

    34

    C

    14

    35

    16

    35

    15

    35

    M

    16

    29

    16

    27

    11

    27

    Y

    19

    30

    19

    30

    14

    25

  • If the value exceeds the maximum limit, the toner is insufficient. In such a case, replenish the toner in the following SP modes (the amount will be sufficient by replenishing up to 6 times):

Related SPs

SP3-015-003: TnrSplyK

SP3-015-004: TnrSplyY

SP3-015-005: TnrSplyM

SP3-015-006: TnrSplyC

  • After replenishing the toner, be sure to execute SP3-017-001 (TnrRmnSnsFc) and SP3-017-002 (TnrRmnSnsBk). Otherwise, the report of the toner amount will not be updated.