- Execute SP3-017-001 (TnrRmnSnsFc) and SP3-017-002 (TnrRmnSnsBk).
- Execute the SPs below, and then check the category of the LED used for the toner-end sensor for each color.
Toner End Sensor
SP
No. to be identified/LED category
BK
3-244-009
29: Category 1
31: Category 2
27: Category 3
C
3-244-016
9: Category 1
5: Category 2
4: Category 3
M
3-244-015
21: Category 1
20: Category 2
16: Category 3
Y
3-244-014
24: Category 1
23: Category 2
20: Category 3
- Check the output count of each color toner in the following SPs.
- SP3-411-005: SnsOutCntAvK
- SP3-411-006: SnsOutCntAvY
- SP3-411-007: SnsOutCntAvM
- SP3-411-008: SnsOutCntAvC
- The amount of the toner is adequate if the [SnsOutCnt] values are within the range of the following table:
Middle-temperature, Middle-humidity conditions (23C 50%)
LED Category
Category 1
Category 2
Category 3
Min.
Max.
Min.
Max.
Min.
Max.
Bk
12
30
15
30
12
27
C
9
30
5
29
4
30
M
21
30
20
31
16
25
Y
24
37
23
37
20
37
High-temperature, High-humidity conditions (27C 80%)
LED Category
Category 1
Category 2
Category 3
Min.
Max.
Min.
Max.
Min.
Max.
Bk
10
29
10
31
10
27
C
16
37
20
37
20
37
M
20
37
15
30
14
28
Y
26
37
20
37
16
37
Low-temperature, Low-humidity conditions (10C 15%)
LED Category
Category 1
Category 2
Category 3
Min.
Max.
Min.
Max.
Min..
Max.
Bk
14
34
14
34
14
34
C
14
35
16
35
15
35
M
16
29
16
27
11
27
Y
19
30
19
30
14
25
- If the value exceeds the maximum limit, the toner is insufficient. In such a case, replenish the toner in the following SP modes (the amount will be sufficient by replenishing up to 6 times):
Related SPs
SP3-015-003: TnrSplyK
SP3-015-004: TnrSplyY
SP3-015-005: TnrSplyM
SP3-015-006: TnrSplyC
- After replenishing the toner, be sure to execute SP3-017-001 (TnrRmnSnsFc) and SP3-017-002 (TnrRmnSnsBk). Otherwise, the report of the toner amount will not be updated.