- Make sure that you have the SMC report (factory settings). This report comes with the machine.
- Insert an SD card in the lower SD slot.
- Plug in, and then turn on the main power switch.
- Start the SP mode.
- Use SP5-990 to print out the SMC reports (“SP Mode Data” and “Logging Data”) if possible.
- Use SP5-824-001 to upload the NVRAM data if possible.
- Turn off the main power switch and unplug the power cord.
- Replace two NVRAMs on the controller and reassemble the machine (Controller Board).

- There are two NVRAMs, "1" [A] and "2" [B]. Install each NVRAM in the corresponding slot as shown in the photo below.
- Install the NVRAMs so that the mark [C] on the NVRAM is on the upper side when the controller board is installed.

- Plug in the power cord.
- Turn on the main power switch.

- When you do this, SC995-02 (Defective NVRAM) will be displayed. However, DO NOT turn off the main power switch. Continue with this procedure.
- Start the SP mode.
- Use SP5-825-001 to download the NVRAM data if possible.
- Make these contract-related settings:
- Counter Method (SP5-045)
- Meter-click Charge Mode (SP5-930, 1-007, 5-083)
- Telephone Number Setting > Fax Telephone Number (SP5-812-002) if the meter charge mode (SP5-930-001) is “ON” (enabled)
- Counter Size Setting (SP5-104)
- Turn off the main power switch, and then remove the SD card from the lower slot.
- Turn on the main power switch.
- Output the SMC data ("ALL") using SP5-990-001, and make sure that it matches the SMC data you printed out in step 5 above (except for the value of the total counter).

- The value of the total counter is reset to “0” when the NVRAM is replaced.
- Do the process control self-check (SP3-011-001).

- Do the following if SP5-824-001 (NVRAM Data Upload) and SP5-825-001 (NVRAM Data Download) cannot be performed for some reason.
- 1. Manually enter all data on the SMC report (factory settings).