- Remove the front cover. (Front Cover)
- Tilt the operation panel to a horizontal position.
- Disconnect the connector (a).
- Remove the screw (b)(M3x8).
Release two hooks (a) and remove the HVP 2 (PCB20) (b).
- When reattaching the HVP 2 (PCB20) (a), insert the lower part of the PCB into four of the lower hooks (b) and insert two right hooks while lift up it. Also, check the terminal spring (c) contacts the terminal (d). (Check from The PCB hole)
- Terminal: Lower side: 5