- Remove the tension spring (a).
*: Take care not to lose the spring. - Release the tension arm (a) to loosen the tension.
- Remove the belt (b).
- Release six hooks (a).
- Remove the toner motor cover (b).
- Disconnect the connector (a) of each toner motor (M11).
- Release each set of two hooks (a).
Remove four toner motors (M11) (b).
- Apply one drop of grease (d) (VSSG9005: MOLYKOTE EM-50L) on the gear surface when attaching the new motor.
Insert the boss (c) to the positioning hole (b) of the toner motor (M11) (a) and reattach it. - Reattach the drive cam (b) if coming off when reattaching the toner motor unit (a).
Check if the drive cam (b) gear is meshed with the lock lever (c) gear when reattaching the toner motor unit (a).
*: Drive can not be released without the drive cam.
- Apply one drop of grease (d) (VSSG9005: MOLYKOTE EM-50L) on the gear surface when attaching the new motor.