The booklet stapler clamp roller motor and booklet stapler exit sensor
cannot be removed until the motor base has been removed.
Preparation
Booklet unit (Booklet Unit Removal)
Motor Base Plate
Remove cover [A] (
x2).
Disconnect sensor bracket [A] and harness [B] (
x1,
x2,
x1).
Disconnect motor harness [A] (
x6,
x1).
Pull belt
until you can see through the hole
that the edge of the actuator
below the hole is aligned as shown.
The edge of the actuator and the line on the left side of the hole must be aligned.
This releases the clamp roller so that there is no pressure on the base plate.
Remove:
[A] Rear (
x2)
[B] Front (
x3)
Remove base plate [A].
Remove end-piece [B].
Exit Sensor
A guide shaft blocks access to the exit sensor bracket [A].
Remove guide shaft screw [A] (
x1).
Rotate then slide the guide shaft [B] to the rear until you have enough space to remove the bracket screw. (The guide does not need to be removed.)
Use a short screwdriver to remove the exit sensor bracket [A] (
x1).
Disconnect the exit sensor [B] (
x1,
x5).
Booklet Stapler Clamp Roller Motor
Preparation
Lay the motor base plate [A] on a flat surface.
Turn the base plate over.
Remove motor [A] (
x2,
x1).
Re-installation
To make sure there is no pressure on the base plate, pull belt
until you can see through the hole
that the edge of the actuator
below the hole is aligned as shown.
Turn gear [A] so that you can see the cut-out. The post of the linkage must be re-inserted here when the motor base plate is re-installed.
After the motor base plate [A] has been re-installed, the linkage will not be straight. It will slant slightly from rear to front. This is normal.
Confirm that the ends of the vertical shafts fit correctly through the holes in the motor base plate before you re-attach any screws.
Re-attach end-piece [A] at the front before you re-attach any other screws.