Preparation

Remove:

  1. These sensors are mounted on the same bracket under the paper path cover.

  2. At the front, disconnect the shaft [A] of plate Rb5. ( x1)

  3. Remove Rb5 [B]

  4. Use a short screwdriver to remove bracket plate [A]. ( x1)

  5. Use a pencil or marker to mark the color and location of the harnesses.

  6. Disconnect a standoff to create slack in the harnesses.

  7. Disconnect the bracket and sensors [A] (x4, x2).

  8. Remove:

    [A] Tray full sensor ( x1)