The stapler junction gate motor is behind the punch unit PCB.

Preparation

Remove:

  1. Open the harness clamps of the motor [A] ( x3)

  2. Disconnect the motor at [B] ( x1)

  3. Remove motor bracket [A] ( x2)

    • Slowly, pull the bracket away.

    • Make sure the Teflon collar [B] does not fall off the end of the junction gate shaft. Remove it so that it does not accidentally slip off the end of the shaft.