- Complete the procedure of "Preparation at the Customer Site". [Link to Preparation at the Customer Site]
- Remove all the USB devices that may be connected to the E-25C.
- Perform the shutdown procedure from the copier operation panel [Link to Shutting Down the E-25C Only]
- When the E-25C power is down (that is when the diagnostic LEDs are off), turn the main power switch of the E-25C to OFF.
- Disconnect all cables from the E-25C connector panel, except the power cable.
Be sure to leave the power cable connected between the E-25C and the power outlet. - Set the E-25C service switches as shown below. ("1" ON, "2" OFF)
Attach the prepared USB flash drive to one of the USB ports on the E-25C.
- If dust covers are attached to the USB Type A ports, remove one dust cover using needle-nosed pliers.
- When using a USB 3.0 flash drive, make sure to attach the USB flash drive to one of the USB 3.0 ports, which are located on the rear of the E-25C. Otherwise installation time will take considerably longer than expected.
[A] USB 2.0 ports
[B] USB 3.0 portsTurn the main power switch of the E-25C to ON, then press and release the soft power push button on the front of the E-25C and wait until installation is complete. (The E-25C shuts down automatically after installation is complete.)
The diagnostic LEDs increment quickly to initialize, then the diagnostic LEDs display C1, C2, C3 continuously, showing that installation (file transfer phase) is under progress.
Installation (file transfer phase) takes approximately 10 minutes. The LED on the USB flash drive should show that files are being transferred.
- Turn the main power switch of the E-25C to OFF and remove the USB flash drive from the E-25C.
- Set the service switches in the normal position. (Not ON)
- Reconnect all cables that you removed earlier from the E-25C rear panel.