There are 3 methods for installing the E-25C system software.

  • Restoring image file from E-25C HDD
  • Network Installation (Using a Network Cable)
  • USB Installation (Using a USB flash drive)

All of these methods will format the HDD before the system software is reloaded.

Fiery Installer Builder
System Software files
Restoring image file from the E-25C HDD

The factory default system files of E-25C already exist in the recovery folder of the E-25C HDD.
Restore this image by changing the service switch. For detailed instructions, see [Link To Restoring the Factory Default System Image File from the E-25C HDD Recovery Folder].

  • It is recommended to try this method first, as it is the simplest method.
  • This method is not applicable in the following cases:
    1) HDD was replaced with a new one.
    2) A more recent system software version needs to be installed.

Network Installation

Download the system software from the internet and install it on E-25C via Windows PC and network cable.

USB Installation

Download the system software from the internet and install it on E-25C via a USB flash drive.

 

  • The procedure at the customer site is easier than ‘Using the Network’ described above.
  • The USB flash drive must have a 16GB - 32GB capacity.