SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-06 | D | Ethernet TCP/IP: Invalid configuration during enable |
Configuration error involved in the communication with the IPDS host system (only occurs when the IPDS installed) | ||
If rebooting the print server does not solve the problem, replace the motherboard. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-10 | D | Internal printing: File system error |
File system error of the internal print (such as file corruption) | ||
If rebooting the print server does not solve the problem, do the following.
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-11 | D | Unexpected network condition |
| ||
If rebooting the print server does not solve the problem, replace the motherboard. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-20 | D | Program check - Type 1 |
SC911-21 | D | Program check - Type 2 |
SC911-22 | D | Program check - Type 3 |
Programming error | ||
Reboot the print server. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-24 | D | CPU0 Temperature Alert |
CPU0 temperature error by H/W checking
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-26 | D | CPU1 Temperature Alert |
CPU1 temperature error by H/W checking
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-42 | D | Memory configuration has changed. |
This error rarely occurs at the initial startup after the software installation because of memory shortage. | ||
If rebooting the print server does not solve the problem, replace the DIMM or the motherboard. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-43 | D | Invalid features defined |
Invalid features defined | ||
Turn the main power off and on. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-44 | D | Recommended amount of memory not found |
DIMM defective | ||
If rebooting the print server does not solve the problem, replace the DIMM. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-45 | D | Recommended number of processors not found |
CPU or motherboard defective | ||
If rebooting the print server does not solve the problem, replace the CPU/ CPU cooling fan or motherboard. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-46 | D | File read error, hard disk |
System files corruption | ||
If rebooting the print server does not solve the problem, do the following.
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-47 | D | File write error, hard disk |
System files corruption | ||
If rebooting the print server does not solve the problem, do the following.
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-48 | D | Checksum error on configuration file. |
System files corruption | ||
If rebooting the print server does not solve the problem, re-install the system software. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-49 | D | Hard disk backup to USB storage device failure |
Abnormal termination due to incomplete backup to the USB memory | ||
If rebooting the print server does not solve the problem, replace the USB memory for backup. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-50 | D | Software update failed. |
Abnormal termination due to the system software update file failure | ||
If rebooting the print server does not solve the problem, re-install the update file. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-57 | D | License key H/W error |
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-58 | D | License error |
| ||
If rebooting the print server does not solve the problem, replace the USB dongle. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-60 | D | Brand mismatch |
An invalid USB dongle is inserted. | ||
If rebooting the print server does not solve the problem, replace the USB dongle. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-61 | D | Command timeout communicating with the printer. |
No response of command level from the printer. | ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-62 | D | Print Engine communication error. |
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-63 | D | A file system access error occurred in the ASCII temporary disk cache. |
System files corruption | ||
If rebooting the print server does not solve the problem, re-install the system software. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-64 | D | Page processing timeout |
Time-out error occurs during the page processing for print job. | ||
If rebooting the print server does not solve the problem, there may be a problem with the job. |