SC500 | Transport/Fusing Motor Error |
The LOCK signal error is detected when the EGB monitors the transport/fusing motor state. (This monitoring is done immediately after power-on, when the motor starts rotating, and immediately after the motor stops.) | |
|
SC530 | LSU Fan Motor Error |
A LOCK signal is not detected for more than ten seconds while the motor START signal is on and if this error occurs twice consecutively, this SC is issued. | |
|
SC531 | Fusing Fan Motor Error |
A LOCK signal is not detected for more than ten seconds while the motor START signal is on and if this error occurs twice consecutively, this SC is issued. | |
|
SC541 | Thermistor Error |
The thermistor output is less than 0°C for 7 seconds. | |
|
SC542 | Print Ready Temperature Error |
| |
|
SC543 | High Temperature Detection Error |
This SC is issued if one of following conditions occurs:
| |
|
SC545 | Heating Lamp Full-Power Error |
The fusing lamp is fully-powered for a certain time while the fusing unit stays in the stand-by mode and is not rotating. | |
|
SC547 | Zero Cross Error |
The zero cross signal is not detected for three seconds even though the fusing lamp relay is on after turning on the main power or closing the front door. | |
|
SC548 | Low Temperature Error |
The center thermistor detects 100°C or less for 4 seconds. | |
|
SC557 | Zero Cross Frequency Error |
The detection error occurs ten times consecutively in ten zero cross signal detections. This error is defined when the detected zero cross signal is 17 or less/27 or more for 0.2 seconds. | |
|
SC559 | Consecutive Fusing Jam |
The paper jam counter for the fusing unit reaches 3. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when this function (Fuser SC Detect) is enabled with the SP mode (default "OFF"). | |
|