When replacing an old EEPROM with a new EEPROM, EEPROM setting is required. Follow the EEPROM setting procedure described below.

  • When you replace the EEPROM, the following counters stored on the EEPROM are cleared:
    • Machine total counter (total page, full color, and B&W)
    • Error log (listed as “Call Service” on Maintenance Page)
    • Duplex page counter
  • Do the following steps 1 to 14 with the front cover of the machine open.

  1. Open the front cover and turn on the machine.

    • The machine may issue an error code (because the cover is open), but continue this procedure.

  2. Enter the SP mode.

  3. Execute "Init Engine EEPROM" in [Engine Service Setting].
    In the printer models, execute "Init. Eng. ROM" in [Engine Maintenance].
    EEPROM Initialization starts.
  4. Exit the SP mode.
  5. Enter the mode for inputting a machine serial number.

    • Ask your supervisor about how to access the serial number input display.

  6. Input the machine serial number.

  7. Exit the serial number input display, and then enter the SP mode again.

  8. Select a destination.
    • MF model: [SP Menu] > [Engine Service Setting] > [Destination]
    • Printer Model: [Service Mode] > [Engine Maintenance] > [Destination]
  9. Select a model.
    • MF model: [SP Menu] > [Engine Service Setting] > [Model]
    • Printer Model: [Service Mode] > [Engine Maintenance] > [Model]
  10. Enter a plug and play name.
    • MF model: [SP Menu] > [Engine Service Setting] > [PnP Name]
    • Printer Model: [Service Mode] > [Engine Maintenance] > [PnP Name] 
      Enter the following plug and play name according to the model:
      SP C260SFNw/SP C260DNw: 0x10

      SP C262SFNw/C262SFNw/SP C262DNw/C262DNw: 0x14

  11.  Write the LD parameters of the laser optics housing unit to the new EEPROM.
    • MF model: [SP Menu] > [Engine Service Setting] > [Init. LSU Data]
    • Printer Model: [Service Mode] > [Engine Maintenance] > [Init. LSU Data]
  12. Turn off the machine.
  13. Turn on the machine with the front cover open.
  14. Enter the SP mode again.
  15. Close the front cover.
  16. Execute "Trans. Belt Adjust" in [Engine Service Setting] to adjust the ITB (Image Transfer Belt) unit.
    In the printer models, execute "Trans. Belt Adj," in [Engine Maintenance].
  17. Select [Fuser SC Detect], and then select "ON" or "OFF" for consecutive fusing jam detection.

    • MF model: [SP Menu] > [Engine Service Setting] > [Fuser SC Detect]
    • Printer Model: [Service Mode] > [Engine Maintenance] > [Fuser SC Detect]

    • The default setting is "OFF". Select "ON" only if the customer wants to use this feature.

  18. Adjust the registration for each direction (vertical and horizontal directions) and tray if necessary.
    • MF model: [SP Menu] > [Engine Service Setting] > [Registration]
    • Printer Model: [Service Mode] > [Engine Maintenance] > [Registration]
  19.  Adjust the transfer roller bias and the temperature reduction of the fusing unit for each paper type and for the front and back sides. The default settings for normal operation are all '0'.
    • MF model: [SP Menu] > [Engine Service Setting] > [2nd Transfer Fuser Temp]
    • Printer Model: [Service Mode] > [Engine Maintenance] > [2nd Transfer]
    • MF model: [SP Menu] > [Engine Service Setting] > [Color Registration]
    • Printer Model: [Service Mode] > [Engine Maintenance] > [Color Regist]
      MUSIC is performed.
  20. If necessary, adjust the registration settings for the front and rear sides of each paper tray with the SP mode.