6136  | [OUTPUT Check: FrontFIN]  | ||
Continuously drives specified motor for operation test.  | |||
6-136-001  | Entrance Motor  | *ENG  | [OFF/ON]  | 
6-136-002  | Carry Motor  | ENG  | [OFF/ON]  | 
6-136-003  | Exit Motor  | ENG  | [OFF/ON]  | 
6136  | [OUTPUT Check: FrontFIN]  | ||
Drives specified motor for a certain period of time to test operation.  | |||
6-136-004  | Front Jogger Motor  | ENG  | [OFF/ON]  | 
6-136-005  | Rear Jogger Motor  | ENG  | [OFF/ON]  | 
6-136-006  | Shift Motor  | ENG  | [OFF/ON]  | 
6-136-007  | Hitroll Motor  | ENG  | [OFF/ON]  | 
6-136-008  | Exit Guide Plate Motor  | ENG  | [OFF/ON]  | 
6-136-009  | Staple Moving Motor  | ENG  | [OFF/ON]  | 
6-136-010  | Tray Motor  | ENG  | [OFF/ON]  | 
6-136-011  | Staple Motor  | ENG  | [OFF/ON]  | 
6-136-012  | Stopper Motor  | ENG  | [OFF/ON]  | 
6-136-013  | Punch Motor  | ENG  | [OFF/ON]  | 
6-136-014  | Punch Moving Motor  | ENG  | [OFF/ON]  | 
6-136-015  | Punch Registration Moving Motor  | ENG  | [OFF/ON]  |