Item | EM | 500K | Note |
---|---|---|---|
Drive rollers | C | - | Wipe with a cloth dampened with ethyl alcohol. |
Driven rollers | C | - | |
Quenching brush | C | - | |
Bearings | C | - | Lubricate with Silicone Grease G-501 when noise occurs. |
Sensors | C | - | Clean with a blower brush. |
Jogger fences | C | - | Lubricate with Silicone Grease G-501 when abnormal noise is generated or abnormal operation occurs. |
Stapler | - | R | Replace when the staple counter in the logging data reached 500k. |