Item | 120K | 240K | 360K | EM | Life | Note |
---|---|---|---|---|---|---|
Scanner | ||||||
Exposure Glass | - | C/I/L | - | C/I/L - | - | Clean with a cleaning cloth. Do not clean with alcohol. Doing so may leave a whitish trace that affects image scanning. |
Sheet-through Exposure Glass | - | C/I/L | - | C/I/L | - | |
Shield Glass | - | - | - | C/I/L | Clean with an optics cloth. | |
PCU | ||||||
Developer | R | - | - | - | - | Clear the PM counter. |
Development Roller | C/I/L | - | - | - | - | Clean |
Development Filter | R | - | - | - | - | Clear the PM counter. |
Development Case | C/I/L | - | - | - | - | Clean the guide plate and remove spots where toner adheres. |
Development Entrance Seal | C/I/L | - | - | C/I/L | - | Remove dust. |
Development Side Seal | R | - | - | - | - | |
Doctor Blade | C/I/L | - | - | - | - | Remove adhering developer. |
Development Bearing | - | R | - | - | - | |
Charge Roller | R | - | - | - | - | Clear the PM counter. |
Charge Roller Cleaner | R | - | - | - | - | |
Cleaning Blade | R | - | - | - | - | |
Cleaning Blade Side Seal | C/I/L | - | - | - | - | |
Cleaning Entrance Seal | C/I/L | - | - | - | - | |
OPC Drum | R | - | - | - | - | Clear the PM counter. |
Pick-off Pawl | R | - | - | - | - | |
Waste Toner Bottle | R | - | - | - | Replace when waste toner bottle full is detected. Clear the PM counter. | |
Quenching Lamp | C/I/L | - | - | - | - | |
Transfer | ||||||
Transfer Unit | R | - | - | - | - | Clear the PM counter. |
Fusing Exit Guide | C/I/L | - | - | - | - | |
ID Sensor | C/I/L | - | - | C/I/L | - | Use a blower brush. |
Fusing | ||||||
Heating Sleeve Belt Unit | - | R | - | - | 260k | Clear the PM counter. |
Fusing Entrance Guide Plate | - | - | - | C/I/L | - | Remove adhering toner. |
Fusing Exit Guide Plate | - | - | - | C/I/L | - | |
Stripper Plate | - | - | - | C/I/L | - | |
Pressure Roller | - | R | - | 260k | Clear the PM counter. | |
Pressure Roller Bearing | - | R | - | 260k | Lubricate (FLUOTRIBO MG GREASE) after replacing the bearing. | |
Thermopile | - | C/I/L | - | C/I/L | - | Clean with a dry cloth. |
Pressure Roller Gear | - | - | - | C/I/L | - | Replace when the gear is worn out. |
Idler Gear | - | - | - | C/I/L | - | |
Fusing Entrance Sensor | C/I/L | - | - | C/I/L | - | Clean the sensor part with a blower brush. |
Fusing Exit Sensor | C/I/L | - | - | C/I/L | - |