Item120K240K360KEMLifeNote
Scanner
Exposure Glass-C/I/L-C/I/L --

Clean with a cleaning cloth.

Do not clean with alcohol. Doing so may leave a whitish trace that affects image scanning.

Sheet-through Exposure Glass-C/I/L-C/I/L-
Shield Glass---C/I/L Clean with an optics cloth.
PCU
DeveloperR----Clear the PM counter.
Development RollerC/I/L----Clean
Development FilterR----Clear the PM counter.
Development CaseC/I/L----Clean the guide plate and remove spots where toner adheres.
Development Entrance SealC/I/L--C/I/L-Remove dust.
Development Side SealR---- 
Doctor BladeC/I/L----Remove adhering developer.
Development Bearing-R--- 
Charge RollerR----Clear the PM counter.  
Charge Roller CleanerR----
Cleaning BladeR----
Cleaning Blade Side SealC/I/L---- 
Cleaning Entrance SealC/I/L---- 
OPC DrumR----Clear the PM counter. 
Pick-off PawlR----
Waste Toner BottleR-- -Replace when waste toner bottle full is detected.
Clear the PM counter.
Quenching LampC/I/L---- 
Transfer
Transfer UnitR----Clear the PM counter.
Fusing Exit GuideC/I/L---- 
ID SensorC/I/L--C/I/L-

Use a blower brush.
Initialize the ID sensor after cleaning.

Fusing
Heating Sleeve Belt Unit-R--260kClear the PM counter.
Fusing Entrance Guide Plate---C/I/L-Remove adhering toner.  
Fusing Exit Guide Plate---C/I/L-
Stripper Plate---C/I/L-
Pressure Roller-R- 260kClear the PM counter.
Pressure Roller Bearing-R- 260kLubricate (FLUOTRIBO MG GREASE) after replacing the bearing.
Thermopile-C/I/L-C/I/L-Clean with a dry cloth.
Pressure Roller Gear---C/I/L-Replace when the gear is worn out. 
Idler Gear---C/I/L-
Fusing Entrance SensorC/I/L--C/I/L-Clean the sensor part with a blower brush. 
Fusing Exit SensorC/I/L--C/I/L-