User Tool Setting
Input the change value (S1) for the fold area with the operation panel.
Size | Set Area | Default | Value Range |
|---|---|---|---|
A3 SEF | S1 | 4mm | ±10mm |
B4 SEF | S1 | 4mm | ±10mm |
A4 SEF | S1 | 4mm | ±10mm |
DLT | S1 | 4mm | ±10mm |
LG | S1 | 4mm | ±10mm |
LT SEF | S1 | 4mm | ±10mm |
12×18 | S1 | 4mm | ±10mm |
8K | S1 | 4mm | ±10mm |
Others | S1 | 4mm | ±10mm |
Unit of Adjustment | 1mm | ||
Adjust with SP mode (*1, *3), user setting (*2), operator adjustment (*3), special operator adjustment (*3). Input the adjustment value for the fold area (L, S2) with the operation panel.
Size | Set Area | Default | Value Range | Set Area | Default | Value Range |
|---|---|---|---|---|---|---|
A3 SEF | L | 0mm | ±4mm | S2 | 0mm | ±4mm |
B4 SEF | L | 0mm | ±4mm | S2 | 0mm | ±4mm |
A4 SEF | L | 0mm | ±4mm | S2 | 0mm | ±4mm |
DLT | L | 0mm | ±4mm | S2 | 0mm | ±4mm |
LG | L | 0mm | ±4mm | S2 | 0mm | ±4mm |
LT SEF | L | 0mm | ±4mm | S2 | 0mm | ±4mm |
12×18 | L | 0mm | ±4mm | S2 | 0mm | ±4mm |
8K | L | 0mm | ±4mm | S2 | 0mm | ±4mm |
Others | L | 0mm | ±4mm | S2 | 0mm | ±4mm |
Unit of Adjustment | 0.2mm | |||||
*1 FD4000
*2 FD5010: For single fold
*3 FD5010: For double fold