1. Check the markings on the tray brackets to determine if the tray is slanting to the left or right.

  2. Remove:
  3. Remove the vertical plate [A] (x4)
  4. Remove the belt cover plate [A] (x8)
  5. Release the tension on the timing belt:
    • Remove spring [1].
    • Loosen tension screw [2].
    • Slide bracket [3] up to the left.
  6. Adjust the belt position:
    • To lower the right side of the tray below the stacker entrance, pull the belt in the direction of the arrow at [A] while rotating the top of the tray lift motor [B] counter-clockwise.
    • To raise the right side of the tray below the stacker entrance, pull the belt in the direction of the arrow at [A] while rotating the top of the tray lift motor [B] clockwise.

 

Re-installation

Whenever the belt cover plate has been removed, you should check and re-set the tension of the transverse belt before re-attaching the belt cover plate.

 

  1. Remove the spring [1].
  2. Loosen screw [2] (do not remove it) to raise the tension bracket to the left.
  3. Hang the belt cover plate [A] on the hook .
  4. Make sure the bearings and are snug in the holes.
  5. Attach screws , , , , , and tighten.
  6. Attach screws , but do not tighten.
  7. Re-attach the removed spring .
  8. Above the spring, pull the tension bracket down [1] as far as it will go, and tighten the tension screw [2]
  9. Tighten all the screws (x8).