Preparation
Remove these parts:
- Jogger unit (Jogger Unit Removal)
 
Fence Retraction Motor
- Disconnect the dual harness [A] for the main jogger fence retraction HP sensor and front fence HP sensor (
x3,
x6).
Front
 - Remove the motor bracket [A] (
x2)
 - Separate the fence retraction motor and the bracket (
x2)
 
Fence Retraction HP Sensor
- Remove the motor bracket
 - Remove the fence retraction HP sensor [A] (
x5)
 
LE Stopper Motor, LE Stopper HP Sensor
LE Stopper Motor  | |
LE Stopper HP Sensor  | 
Preparation
Remove these parts:
- Jogger unit (Jogger Unit Removal)
 
LE Stopper Motor
- Remove the motor bracket [A] (
x2,
x1)
 - Separate the LE stopper motor and the bracket (
x2)
 
LE Stopper HP Sensor
- Remove the sensor [A] (
x1,