SP6-006-001 (ADF Adjustment Side-to-Side Regist: Front)

SP6-006-002 (ADF Adjustment Side-to-Side Regist: Rear)

  1. Create an original as shown in the following picture.

    The arrows indicate the direction of feed.

  2. Copy the original and make sure that the position of the line [A] is within 0±1mm
  3. If not within the standard, adjust with the SP modes.