When an SC is generated, the voltages of the input power source and the SC code can be displayed with the following SPs. When the SC is generated, the maximum and minimum voltages of the input power source within a predetermined period of time (5 seconds before the generation of the SC) are also stored in SP mode.

SP No.SP NameRangeDescription
SP5-961-001

Power Supply Voltage: Disp – Power Supply Voltage

0 to 300V

The voltage during normal operation:

The machine acquires the voltage every 0.5 seconds, and stores it in SP mode.

SP5-962-001 to 010

SC Number (Error) – SC Number (Error)1 to 100 to 99999

The SC code when the SC is generated:

For example, "54702" is displayed when SC547-02 is generated. The newest 10 SC codes are stored in SP mode.

SP5-963-001 to 010*1Max Power Supply Voltage – Max Power Supply Voltage1 to 100 to 300V

The maximum voltage when the SC is generated:

Displays the maximum voltage value within a predetermined period of time (5 seconds before the generation of the SC). The most recent 10 maximum voltage values are stored in SP mode.

SP5-964-001 to 010*1Min Power Supply Voltage – Min Power Supply Voltage10 to 300V

The minimum voltage value when the SC is generated:

Displays the minimum voltage value within a predetermined period of time (5 seconds before the generation of the SC). The most recent 10 minimum voltage values are stored in SP mode.

*1 If the SC is generated before the machine acquires the voltage of the input power source, "1" or "2" is displayed.

  • The voltage of the input power source displayed in SP mode has a ±4% deviation from the actual value.
  • If you need to check the voltage of the input power source with the SMC output, execute SP5-990-002 (SP Print Mode – SP (Mode Data List)). The voltage of the input power source is not on the SMC output of SP5-990-004 (SP Print Mode – Logging Data).