SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC540-00 | A | Fusing Drive Motor: Lock |
The IOB detects the fusing drive motor lock error (rotation speed out of specification). Vodka assignment: GPIO26DATA[1] Details: When the fusing drive motor is on, each lock signal is checked every 100 milliseconds. If the High status is detected 20 times consecutively, the machine determines that the fusing drive motor is not running correctly. The machine issues an SC and stops the fusing drive motor. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC541-00 | A | Sensor 1: Heating Roller Center Disconnection |
0 degrees or lower was detected for (t11) seconds consecutively. NA: t11= 30 EU/AP/CHN: t11= 20 Number of times: 10 or more Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off). | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC542-02 | A | Sensor 1: Pressure Roller Center: Reload Failure: Timeout 1 |
Failed to reach (T2) degrees centigrade after (t4) seconds from the start of heater control. MP C6503 SP (NA): T2= 113, t4= 59 MP C6503 SP (EU/AP/CHN): T2= 119, t4= 59 MP C8003 SP (NA): T2= 121, t4= 59 MP C8003 SP (EU/AP/CHN): T2= 119, t4= 59 Pro C5200S/Pro C5210S: T2= 139, t4 = 59 Monitored at: Startup (Power-on, when a cover is closed, when fusing heater is under control) | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC542-03 | A | Sensor 1: Heating Roller Center: Reload Failure: Timeout 2 |
Failed to reach reload temperature after (t23) seconds from reaching (T2) degrees of SC542-02. MP C6503 SP (NA): T2= 113, t23= 50 MP C6503 SP (EU/AP/CHN): T2= 119, t23= 40 MP C8003 SP (NA): T2= 34, t23= 34 MP C8003 SP (EU/AP/CHN): T2= 119, t23= 40 Pro C5200S/Pro C5210S: T2= 139, t23 = 18 Monitored at: Startup (Power-on, when a cover is closed, when fusing heater is under control) | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC543-00 | A | Sensor 1: Heating Roller Center: Overheat detection (software) |
250 degrees centigrade or higher was detected for 1 second consecutively. Number of times: 10 or more Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off). | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC544-00 | A | Heating Roller Center: Overheat detection (hardware) |
Hardware detection of overheat condition. The thermopile (heating roller) was detected as the cause. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC547-01 | D | Zero Cross Error (Relay contact welded) |
When this error occurs, machine stops with fusing relay off and displays the SC. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC547-02 | D | Zero Cross Error (Relay contact defective) |
When this error occurs, the fusing heater trigger turns off and then, after a specified time, machine stops with fusing relay off and displays the SC. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC547-03 | D | Zero Cross Error (low frequency error) |
When this error occurs, the fusing heater trigger turns off and then, after a specified time, machine stops with fusing relay off and displays the SC. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC547-04 | D | AC drive board: Not connected |
After the interlock door is fixed to close, AC drive board: connection detecting signal (CNCON) is not detected. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC547-11 | D | Fusing relay contact welded (resulting from zero cross 2) |
After the interlock door is fixed to close, the zero cross 2 signal is detected before turning ON the fusing relay. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC547-12 | D | Fusing relay contact defective (resulting from zero cross 2) |
After fusing relay is ON, the zero cross 2 signal is not detected. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC548-00 | A | Fusing rotation detection |
Blocking/non-blocking signal of the heating roller rotation sensor was not received within specified time. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC550-01 | D | Fusing belt smoothing roller drive motor: Lock |
The IOB detects the fusing belt smoothing drive motor lock error (rotation speed out of specification). Vodka assignment: GPIO28DATA[7] Details: When the fusing belt smoothing drive motor is on, each lock signal is checked every 100 milliseconds. If the High status is detected 20 times consecutively, the machine determines that the motor is not running correctly. The machine issues an SC and stops the motor. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC551-00 | A | Sensor 4: Pressure Roller Center Disconnection |
0 degrees or lower was detected for (t14) seconds consecutively. MP C6503 SP (NA): t14= 45 MP C6503 SP (EU/AP/CHN): t14= 35 MP C8003 SP: t14= 35 Pro C5200S/Pro C5210S: t14 = 80 Number of times: 10 or more Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off). | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC552-02 | A | Sensor 4: Heating Roller Center: Reload Failure: Timeout 1 |
Failed to reach (T24) degrees centigrade after (t25) seconds from the start of heater control. MP C6503 SP (NA): T24= 81, t25= 48 MP C6503 SP (EU/AP/CHN): T24= 96, t25= 48 MP C8003 SP (NA): T24= 98, t25= 48 MP C8003 SP (EU/AP/CHN): T24= 96, t25= 48 Pro C5200S/Pro C5210S: T24= 46, t25= 63 Monitored at: Startup (Power-on, when a cover is closed, when fusing heater is under control) | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC552-03 | A | Sensor 4: Heating Roller Center: Reload Failure: Timeout 2 |
Failed to reach reload temperature after (t26) seconds from reaching (T24) degrees of SC552-02. MP C6503 SP (NA): T24= 81, t26= 16 MP C6503 SP (EU/AP/CHN): T24= 96, t26= 10 MP C8003 SP (NA): T24= 98, t26= 10 MP C8003 SP (EU/AP/CHN): T24= 96, t26= 10 Pro C5200S/Pro C5210S: T24= 46, t26= 80 Monitored at: Startup (Power-on, when a cover is closed, when fusing heater is under control) | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC553-00 | A | Sensor 4: Pressure Roller Center: Overheat detection (software) |
220 degrees centigrade or higher was detected for 1 second consecutively. Number of times: 10 or more Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off). | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC554-00 | A | Pressure Roller Center: Overheat detection (hardware) |
Hardware detection of overheat condition. The pressure roller center thermopile was detected as the cause. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC555-00 | A | Heater 2: Heater Continuously On (Sensor 4: Thermopile: Pressure Roller) |
The machine wait 25 seconds after the condition ([A] and [B]) is satisfied. After the 25 seconds is passed, the machine repeat the followings. 1. Wait for 20 seconds (detection time). 2. If the temperature difference between when the machine start waiting detection time and when the detection time is passed is 6 degree or lower, SC is issued. However, If [C] is satisfied, the SC is not issued until the condition ([A] and [B]) is satisfied again. Monitor interval [A]: Standby/Low power mode Monitor start trigger[B]: When the pressure roller fusing lamp is ON and the fusing drive is stop rotating Monitor end trigger [C]: When the pressure roller fusing lamp is OFF and the fusing drive is rotating | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC559-00 | A | Fusing jam: 3 counts |
Fusing jam (fusing paper feed sensor late jam) was detected 3 times consecutively. Details: This SC can be set ON/OFF. The factory setting is OFF; set it ON when requested by the customer. SP1-142-001: 0: ON (set by service personnel at the request of customer) 1: OFF (factory setting) Conditions of the fusing jam counter reset:
| ||
| ||
- |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC560-00 | D | Cleaning web unit contact error |
Contact/separation control failed 3 times consecutively. Monitored when contact/separation mechanism is operating. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC561-00 | A | Sensor 2: Heating Roller Front Disconnection |
0 degrees or lower was detected for 50 seconds consecutively. Number of times: 10 or more Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off). | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC562-02 | A | Sensor 2: Heating Roller Front: Reload Failure: Timeout 1 |
Failed to reach 45 degrees centigrade after 80 seconds from the start of heater control. Monitored at: Startup (Power-on, when a cover is closed, when fuser heater is under control) | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC562-03 | A | Sensor 2: Heating Roller Front: Reload Failure: Timeout 2 |
Failed to reach reload temperature after 350 seconds from the start of heater control. Monitored at: Startup (Power-on, when a cover is closed, when fuser heater is under control) | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC563-00 | A | Sensor 2: Heating Roller Front: Overheat detection (software) |
250 degrees centigrade or higher was detected for 1 second consecutively. Number of times: 10 or more Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off). | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC564-00 | A | Heating Roller Front: Overheat detection (hardware) |
Hardware detection of overheat condition. The heating roller front thermistor was detected as the cause. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC569-02 | D | Pressure Release Error: HP failed 3 times |
Pressure release/Home position/control failed 3 times consecutively. Monitored when the pressure release mechanism is operating. Pressure Change: SP1-151-001 1:On/0: Off When this SP is set to OFF, SC detection is disabled. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC569-03 | D | Pressure Release Error: Overrun |
When sensor A shows Low and Sensor B shows High. Except when home position is detected. Monitored when the pressure release mechanism is operating. Pressure Change: SP1-151-001 1:On/0: Off When this SP is set to OFF, SC detection is disabled. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC569-04 | D | Pressure Release Error: Failed to pressure |
When "Sensor A: Low" is not detected within 1000 msec from the start of pressure application. Monitored when the pressure release mechanism is operating. Pressure Change: SP1-151-001 1:On/0: Off When this SP is set to OFF, SC detection is disabled. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC570-00 | D | Fusing Belt Smoothing Roller Contact Error |
Contact/separation/control failed 3 times consecutively. Monitored when the contact/separation mechanism is operating. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC579-00 | A | Sensor 7: Fusing Roller Core Disconnection |
0 degrees or lower was detected for 1000 seconds consecutively. Number of times: 10 or more Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off). Monitored only when SP1-107-024 is set to ON. SP1-107-024: 0: OFF (default) 1: ON | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC580-03 | A | Sensor 7: Fusing Roller Core: Reload Failure: Timeout 2 |
Failed to reach reload temperature after 2700 seconds from the start of heater control. Monitored at: Startup (Power-on, when a cover is closed, when pressure roller fusing lamp is under control) | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC582-01 | A | IGBT Overvoltage Error |
Error notification from the IH inverter with a command (command: 0x64, response value: bit 0) | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC582-02 | D |
|
| ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC583-05 | D | Fusing Guide Plate Sensor Error |
The error is detected when the guide plate sensor is OFF after 200 msec from the drawer lock completion. The error is not detected while the drawer set sensor is ON. | ||
| ||
|