1. Remove the original tray. (Original Tray)
  2. Remove the original feed unit. (Original Feed Unit)
  3. Remove the DF inner cover [A].

  4. Remove the top cover [A].
  5. Remove the two screws of the registration sensor bracket [A].
    The bracket cannot be removed from the DF unit, because doing so interferes with the paper transfer roller. However, remove the screws to make space for removing the registration sensor.
  6.  Remove the connector of the registration sensor [A].
  7. Disengage the hooks, and then, using tweezers, rotate the registration sensor [A] into a sideways position (as shown) and pull it out.
  8.  To pull the registration sensor out, it is recommended to slightly lift the bracket with the fingers to make space.


Attaching the Registration Sensor and Adjusting it after Replacement
  1. Attach the connector to the registration sensor before attaching the registration sensor to the bracket.
  2. Insert the registration sensor sideways [A] into the bracket. Otherwise, it cannot be inserted [B].
  3. Lifting the registration sensor with tweezers, engage the right hook.
  4. Lifting the connector with a finger, engage the left hook.
  5. Screw the bracket [A] on.
     

     

    Be careful not to tighten the screws too much. Doing so may deform the bracket.

  6. Reattach the removed parts.
  7. Open the DF, and cover the exposure glass with a mat [A] or something to prevent it from being damaged.
  8. Remove the two screws of the ID card feeder [A], and place it on the mat gently.

  9. Check the degree of protrusion of the registration sensor (the position of its tip) with a ruler. If it is within 4 to 5 mm, the sensor is correctly attached. If not, the registration sensor bracket may be attached (screwed on) incorrectly, so reattach the bracket.
  10. Check the movement of the registration sensor’s actuator. Rotate it in the direction of the arrow. If it moves without getting snagged, it is attached correctly. If it gets snagged or does not move, the registration sensor bracket may be attached (screwed on) incorrectly, so reattach the bracket.
  11. After checking the actuator movement, return the ID card feeder to its original position.

    When attaching the ID card feeder, be sure to begin with the screw [A] at the bottom (rear).

  12. Scan a document to check for vertical registration errors. If there is a registration error, adjust using the following SPs.
      • SP6-006-010 (ADF Adjustment L-EdegeResist: Front)
      • SP6-006-011 (ADF Adjustment L-EdegeResist: Back)
      • SP6-006-012 (ADF Adjustment Manual Feed L-EdegeResist: Front)
      • SP6-006-013 (ADF Adjustment Manual Feed L-EdegeResist: Back)