When re-attaching the HP sensor bracket:

  • Confirm that hooks [A] and [B] are firmly inserted and locked in place.
    The HP sensor will fail to operate correctly if the bracket is not positioned correctly.
  • Check the front of the unit where the de-curl roller unit was removed.
    The plunger [A] should not be visible. If the depressor [A] is down and visible, it will interfere with the re-installation of the de-curl roller unit. You need to raise the depressor.

    To raise the depressor, rotate the timing belt [A] and the drive gear of the de-curl pressure adjustment motor counterclockwise until you can no longer see the plunger at [B].