If double feed occurs several times when paper is fed from an LCT (1st, 2nd and 3rd), try to change the upper limit of the paper stack in the LCT tray. Changing the upper limit of the paper stack in the LCT tray can improve paper separation for the paper stack in the LCT tray.
- Remove the paper feed unit of the LCT unit. (Removing the Vertical Feed Unit)
- Loosen the screw on the paper lift sensor bracket [A].
- Move the bracket 0.5 mm in the arrow direction as shown above.
Tighten the screw on the paper lift sensor bracket [A].
- To return the upper limit position to the default position, move the paper lift sensor bracket 0.5 mm in the opposite direction.
- Return the upper limit position to the default if a paper jam occurs at the paper feed sensor in the LCT.