Input Check
No. | Part Name | SP Name | SP No. | Reading | |
---|---|---|---|---|---|
0 | 1 | ||||
1 | Duplex entrance sensor | Fusing Fan: Lock | 5-803-032 | Lock | Normal |
2 | Right cover switch | Laser Unit Fan: Lock | 5-803-033 | Lock | Normal |
3 | Paper exit sensor | PSU Fan: Lock | 5-803-035 | Lock | Normal |
4 | Duplex exit sensor | PCDU Cooling Fan: Lock | 5-803-034 | Lock | Normal |
- | - | PP:T1T2:SC Detection | 5-803-045 | SC detected | No SC |
- | - | PP:CB:SC Detection | 5-803-044 | SC detected | No SC |
- | - | BiCU Version Detection | 5-803-056 | - | - |
- | - | Key Counter 1: Set Detection | 5-803-047 | Set | Not set |
- | - | Key Counter 2: Set Detection | 5-803-048 | Not set | Set |
- | - | Keycard: Set Detection | 5-803-049 | Set | Not set |
Output Check
No. | Part Name | SP Name | SP No. | Remark |
---|---|---|---|---|
1 | Fusing fan | Fusing Fan: High Speed | 5-804-009 | |
Fusing Fan: Low Speed | 5-804-010 | |||
2 | LD unit fan | Laser Unit Fan: High Speed | 5-804-011 | |
Laser Unit Fan: Low Speed | 5-804-012 | |||
3 | PCDU cooling duct fan | PCDU Cooling Fan: High Speed | 5-804-015 | |
PCDU Cooling Fan: Low Speed | 5-804-016 | |||
4 | PSU fan | PSU Fan: High Speed | 5-804-013 | |
PSU Fan: Low Speed | 5-804-014 | |||
- | - | PP:Charge DC:Y | 5-804-044 | Do not turn ON these SPs with the PCDU installed. If you turn ON with the PCDU installed, an electric current continues to flow in a particular place of the drum. Therefore the drum may be damaged electrostatically. Note: If you turn ON these SPs multiple at the same time, and turn OFF one of the SPs, all of the output will be stopped. When you want to stop the outputs, turn OFF all of the SPs turned ON. |
- | - | PP:Charge DC:M | 5-804-045 | |
- | - | PP:Charge DC:C | 5-804-046 | |
- | - | PP:Charge DC:Bk | 5-804-047 | |
- | - | PP:Development: Y | 5-804-048 | |
- | - | PP:Development: M | 5-804-049 | |
- | - | PP:Development: C | 5-804-050 | |
- | - | PP:Development: Bk | 5-804-051 | |
- | - | PP: Image Transfer: YMC | 5-804-053 | Do not turn ON these SPs with the PCDU installed. If you turn ON with the PCDU installed, an electric current continues to flow in a particular place of the drum. Therefore the drum may be damaged electrostatically. |
- | - | PP: Image Transfer: Bk | 5-804-056 | |
- | - | PP: Paper Transfer: + | 5-804-057 | |
- | - | PP: Paper Transfer: - | 5-804-058 | |
- | - | PP:Charge AC:Y | 5-804-059 | Do not use these SPs, otherwise SC312 will occur. |
- | - | PP:Charge AC:M | 5-804-061 | |
- | - | PP:Charge AC:C | 5-804-063 | |
- | - | PP:Charge AC:Bk | 5-804-065 |