Input Check
No.Part NameSP NameSP No.Reading
01
1Fusing motorFusing Motor: Lock5-803-041LockNormal
2

Paper transport motor

Transport Motor: Lock5-803-042LockNormal
3Development motor (CMY)FC Dev Motor: Lock5-803-039LockNormal
4Drum motor (CMY)FC Drum Motor: Lock5-803-040Lock

Normal

5Drum motor (K)Bk Drum Motor: Lock5-803-038LockNormal
Output Check
No.
Part Name
SP Name
SP No.
Remark
1Fusing motorFusing Motor: Standard Speed 15-804-029

Do not use these SPs, but use following SPs instead.

  • SP1-158-001 (Abnormal Noise Confirmation: Unit: Execute)
  • SP1-158-002 (Abnormal Noise Confirmation: No Unit: Execute)

A simple heater control is performed in these SPs, and temperature rises excessively. It can cause the fusing sleeve damaged.

Fusing Motor: Low Speed5-804-030
Fusing Motor: Standard Speed 25-804-091
Fusing Motor: Middle Speed5-804-096
2Paper transport motorTransport Motor: Std Speed 15-804-031 
Transport Motor: Low Speed5-804-032 
Transport Motor: Standard Speed 25-804-092 
Transport Motor: Middle Speed5-804-097 
3Development motor (CMY)FC Dev Motor: Std Speed 15-804-024 
FC Dev Motor: Low Speed5-804-025 
FC Dev Motor: Middle Speed5-804-094 
4Drum motor (CMY)FC Drum Motor: Std Speed 15-804-027

When you turn ON the motor with these SPs, make sure to separate the color drums and ITB.

Before the restoration operation of the machine after abnormal stop, for example JAM, if the drum motor (CMY) is turned ON with these SPs, only the color drums drive. At this time, the ITB has stopped but the ITB is in contact with the color drums. Therefore the color drums and the ITB may be damaged.

FC Drum Motor: Low Speed5-804-028
FC Drum Motor: Middle Speed5-804-095
5Drum motor (K)Bk Drum Motor: Std Speed 15-804-022

When you turn ON the motor with these SPs, make sure to separate the color drums and ITB.

Before the restoration operation of the machine after abnormal stop, for example JAM, if the drum motor (K) is turned ON with these SPs, the K drum and ITB drive. At this time, the color drums have stopped but the color drums are in contact with the ITB. Therefore the color drums and the ITB may be damaged.

In addition, if keeps ON for a long time, the cleaning blade can be distorted. When you keeps ON with the ITB unit installed, make sure to do it within 10 seconds.

Bk Drum Motor: Low Speed5-804-023
Bk Drum Motor: Standard Speed 25-804-090
Bk Drum Motor: Middle Speed5-804-093
6Development Clutch (K)Development Clutch: Bk5-804-026