This product has been designed for user maintenance. The maintenance kits in the table below have been prepared as supplies. User maintenance is performed by replacing these supplies.
The yield figures are based on the following conditions:
- A4 (LT): long-edge feed
- 5% image coverage ratio
- 3 prints/job
- Environment: Normal temperature and humidity
Yield may change depending on circumstances and print conditions.
Symbol keys: C: Clean, R: Replace, L: Lubricate, I: Inspect, U: Maintenance by User, S: Maintenance by Service
PCDU
Item | U or S | Maintenance Cycle | PM Parts | Remarks |
---|---|---|---|---|
PCDU (K) | U | R 60K | ||
PCDU (C,M,Y) | U | R 60K | ||
Waste toner bottle | U | R 80K | Replace if the waste toner bottle is detected to be full. |
Transfer
Item | U or S | Maintenance Cycle | PM Parts | Remarks |
---|---|---|---|---|
Image transfer belt unit | U | R 200K |
| The image transfer belt also includes the image transfer cleaning unit, which is replaced together with the image transfer unit. |
Paper transfer roller unit* | U | R 160K | Replace the paper transfer roller unit, fusing unit, and ozone filter/dust filter together. |
*When replacing the roller, check which one is installed in the unit, a normal roller or an optional Imageable Area Extension Unit.
Fusing
Item | U or S | Maintenance Cycle | PM Parts | Remarks |
---|---|---|---|---|
Fusing unit | U | R 160K | Replace the paper transfer roller unit, fusing unit, and ozone filter/dust filter together. |
Miscellaneous
Item | U or S | Maintenance Cycle | PM Parts | Remarks |
---|---|---|---|---|
Ozone filter/Dust filter | U | R 160K | Replace the paper transfer roller unit, fusing unit, and ozone filter/dust filter together. | |
Dust shield glass for Laser Unit | S/U | C As needed | Clean the dust shield glass with a cleaning brush. | |
TM/ID sensor | S | C As needed | Damp cloth Do not use a dry cloth that can cause static electricity. |
Paper Feed
Perform cleaning when the frequency of sensor failure, double feeding, or jam increases.
Item | U or S | Maintenance Cycle | PM Parts | Remarks |
---|---|---|---|---|
Registration roller | S | C As needed | Damp cloth Remove the paper dust. | |
Registration sensor | S | C As needed | Clean sensors with a blower brush. Remove the paper dust. | |
Paper dust collection unit
| S | C As needed | Damp cloth Remove the paper dust. | |
Feed roller 1/2 | S | C As needed | Damp cloth Remove the paper dust. | |
Pick-up roller 1/2 | S | C As needed | Damp cloth Remove the paper dust. | |
Separation roller 1/2 | S | C As needed | Damp cloth Remove the paper dust. | |
Bypass paper feed roller | S | C As needed | Damp cloth Remove the paper dust. | |
Bypass pick-up roller | S | C As needed | Damp cloth Remove the paper dust. | |
Bypass transport roller | S | C As needed | Damp cloth Remove the paper dust. | |
Transport roller 1/2 | S | C As needed | Damp cloth Remove the paper dust. | |
Transport sensor 1/2 | S | C As needed | Clean sensors with a blower brush. Remove the paper dust. | |
Paper feed sensor 1/2 | S | C As needed | Clean sensors with a blower brush. Remove the paper dust. | |
Friction pad (tray1/2, bypass tray) | S | C As needed | Damp cloth Remove the paper dust. |
Duplex
Perform cleaning when the frequency of sensor failure, double feeding, or jam increases.
Item | U or S | Maintenance Cycle | PM Parts | Remarks |
---|---|---|---|---|
Duplex transport roller 1/2 | S | C As needed | Damp cloth Remove the paper dust. | |
Duplex exit sensor | S | C As needed | Clean sensors with a blower brush. Remove the paper dust. |
Paper Exit
Perform cleaning when the frequency of sensor failure, double feeding, or jam increases.
Item | U or S | Maintenance Cycle | PM Parts | Remarks |
---|---|---|---|---|
Paper exit roller | S | C As needed | Damp cloth Remove the paper dust. | |
Reverse roller | S | C As needed | Damp cloth Remove the paper dust. | |
Paper exit sensor | S | C As needed | Clean sensors with a blower brush. Remove the paper dust. | |
Reverse sensor | S | C As needed | Clean sensors with a blower brush. Remove the paper dust. | |
Fusing exit sensor | S | C As needed | Clean sensors with a blower brush. Remove the paper dust. |