1. The rollers are behind the snap-off cover.
  2. Pull off cover [A].
  3. Remove screw [B].
  4. Remove plate [A].
  5. Remove screw [B].
  6. Push the sensor positioning plate to the left.

    • If this plate is not pushed to the left, you will not be able to remove the feed roller.

  7. Remove:
    [A] Pick-up roller snap ring and roller.
    [B] Feed roller snap ring and roller.
  8. Remove the separation snap ring and roller [A].
  9. After installing new rollers, turn on the machine and wait for it to warm up.
  10. Re-set the PM Counts for the replaced rollers.