SP No. | Large Category | Small Category | ENG or CTL | [Min to Max/Init./Step] |
---|---|---|---|---|
5-008-002 | Operation Panel Buzzer | Buzzer Volume | CTL* | [ 2 to 5 / 4 / 1] |
5-024-001 | mm/inch Display Selection | 0:mm 1:inch | CTL* | [ 0 to 1 / * / 1] *NA: 1 *EU/AP/CHN/TWN/KOR: 0 |
5-024-002 | C/F Display Selection | 0:Celsius 1:Fahrenheit | CTL* | [ 0 to 1 / * / 1] *NA: 1 *EU/AP/CHN/TWN/KOR: 0 |
5-062-001 | Head | Part Replacement Alert Display | CTL* | [ 0 to 1 / 0 / 1] |
5-062-011 | Ink Supply Pump | Part Replacement Alert Display | CTL* | [ 0 to 1 / 0 / 1] |
5-062-041 | Filter | Part Replacement Alert Display | CTL* | [ 0 to 1 / 0 / 1] |
5-102-001 | Auto Reset | Print Suspended Screen | CTL* | [ 1 to 120 / 10 / 1min] |
5-103-001 | Screen Dsp Set | Heater Setting Screen | CTL* | [ 0 to 1 / 0 / 1] |
5-302-002 | Set Time | Time Difference | CTL* | [ -1440 to 1440 / * / 1] *NA: -300 *EU: 60 *AP/CHN/TWN: 480 *KOR: 540 |
5-302-003 | Set Time | Set Date | CTL | [ 19900101 to 20371231 / 0 / 1] |
5-302-004 | Set Time | Set Time | CTL | [ 0 to 235959 / 0 / 1] |
5-305-001 | Auto Off Set | Set Function | CTL* | [ 0 to 1 / 0 / 1] |
5-307-001 | Daylight Saving Time | Setting | CTL* | [ 0 to 1 / * / 1] *NA/EU: 1 *AP/CHN/TWN/KOR: 0 |
5-307-003 | Daylight Saving Time | Rule Set(Start) | CTL* | [ 0 to 0xffffffff / * / 1] *NA: 0x03200210 *EU: 0x03500010 *AP: 0x10500010 *CHN/TWN/KOR: 0 |
5-307-004 | Daylight Saving Time | Rule Set(End) | CTL* | [ 0 to 0xffffffff / * / 1] *NA: 0x11100200 *EU: 0x10500100 *AP: 0x03100000 *CHN/TWN/KOR: 0 |
5-504-001 | Jam Alarm | CTL* | [ 0 to 3 / 3 / 1] | |
5-504-002 | Jam Alarm | Threshold | CTL* | [ 1 to 99 / 10 / 1] |
5-505-001 | Error Alarm | CTL* | [ 0 to 255 / 19 / 1] | |
5-505-002 | Error Alarm | Threshold | CTL* | [ 1 to 99 / 10 / 1] |
5-507-003 | Supply/CC Alarm | Ink Supply Alarm | CTL* | [ 0 to 1 / 1 / 1] |
5-507-080 | Supply/CC Alarm | Ink Call Timing | CTL* | [ 0 to 1 / 1 / 1] 0:At replacement 1:At near end |
5-507-081 | Supply/CC Alarm | Cleaning Liquid Call Timing | CTL* | [ 0 to 1 / 1 / 1] 0:At replacement 1:At near end |
5-507-082 | Supply/CC Alarm | Web Call Timing | CTL* | [ 0 to 1 / 1 / 1] 0:At replacement 1:At near end |
5-507-083 | Supply/CC Alarm | Ink Call Threshold | CTL* | [ 10 to 90 / 30 / 10%] |
5-507-084 | Supply/CC Alarm | Cleaning Liquid Call Threshold | CTL* | [ 10 to 90 / 20 / 10%] |
5-507-085 | Supply/CC Alarm | Web Call Threshold | CTL* | [ 10 to 90 / 20 / 10%] |
5-515-001 | SC/Alarm Setting | SC Call | CTL* | [ 0 to 1 / 1 / 1] |
5-515-004 | SC/Alarm Setting | User Call | CTL* | [ 0 to 1 / 1 / 1] |
5-515-006 | SC/Alarm Setting | Communication Test Call | CTL* | [ 0 to 1 / 1 / 1] |
5-515-007 | SC/Alarm Setting | Machine Information Notice | CTL* | [ 0 to 1 / 1 / 1] |
5-515-008 | SC/Alarm Setting | Alarm Notice | CTL* | [ 0 to 1 / 1 / 1] |
5-515-009 | SC/Alarm Setting | Non Genuine Cartridge Alarm | CTL* | [ 0 to 1 / 1 / 1] |
5-515-010 | SC/Alarm Setting | Supply Automatic Ordering Call | CTL* | [ 0 to 1 / 1 / 1] |
5-515-012 | SC/Alarm Setting | Jam Alarm | CTL* | [ 0 to 1 / 1 / 1] |
5-701-001 | Controller Bit SW | BitSwitch#0 | CTL* | [ 0x00 to 0xFF / 0 / 1] |
5-701-002 | Controller Bit SW | BitSwitch#1 | CTL* | [ 0x00 to 0xFF / 0 / 1] |
5-801-001 | Memory Clear | All Clear | CTL | [ 0 to 0 / 0 / 0] |
5-801-003 | Memory Clear | CONFIG | CTL | [ 0 to 0 / 0 / 0] |
5-801-004 | Memory Clear | NRS | CTL | [ 0 to 0 / 0 / 0] |
5-801-005 | Memory Clear | NETWORK | CTL | [ 0 to 0 / 0 / 0] |
5-801-006 | Memory Clear | SYSTEM | CTL | [ 0 to 0 / 0 / 0] |
5-801-007 | Memory Clear | FWU | CTL | [ 0 to 0 / 0 / 0] |
5-812-001 | Service Tel. No. Setting | Service | CTL* | [ 0 to 0 / 0 / 0] |
5-812-003 | Service Tel. No. Setting | Supply | CTL* | [ 0 to 0 / 0 / 0] |
5-816-002 | Remote Service | CE Call | CTL | [ 0 to 1 / 0 / 1] |
5-816-003 | Remote Service | Function Flag | CTL* | [ 0 to 1 / 0 / 1] |
5-816-061 | Remote Service | Cert Expire Timing | CTL* | [ 0 to 0 / 0 / 0] |
5-816-062 | Remote Service | Use Proxy | CTL* | [ 0 to 0 / 0 / 1] |
5-816-063 | Remote Service | Proxy Host | CTL* | [ 0 to 0 / 0 / 0] |
5-816-064 | Remote Service | Proxy PortNumber | CTL* | [ 0 to 0xffff / 0 / 1] |
5-816-065 | Remote Service | Proxy User Name | CTL* | [ 0 to 0 / 0 / 0] |
5-816-066 | Remote Service | Proxy Password | CTL* | [ 0 to 0 / 0 / 0] |
5-816-067 | Remote Service | CERT:Up State | CTL* | [ 0 to 255 / 0 / 1] |
5-816-068 | Remote Service | CERT:Error | CTL* | [ 0 to 255 / 0 / 1] |
5-816-069 | Remote Service | CERT:Up ID | CTL* | [ 0 to 0 / 0 / 0] |
5-816-087 | Remote Service | CERT:Macro Ver. | CTL* | [ 0 to 0 / 0 / 0] |
5-816-088 | Remote Service | CERT:PAC Ver. | CTL* | [ 0 to 0 / 0 / 0] |
5-816-089 | Remote Service | CERT:ID2Code | CTL* | [ 0 to 0 / 0 / 0] |
5-816-090 | Remote Service | CERT:Subject | CTL* | [ 0 to 0 / 0 / 0] |
5-816-091 | Remote Service | CERT:SerialNo. | CTL* | [ 0 to 0 / 0 / 0] |
5-816-092 | Remote Service | CERT:Issuer | CTL* | [ 0 to 0 / 0 / 0] |
5-816-093 | Remote Service | CERT:Valid Start | CTL* | [ 0 to 0 / 0 / 0] |
5-816-094 | Remote Service | CERT:Valid End | CTL* | [ 0 to 0 / 0 / 0] |
5-816-103 | Remote Service | Client Communication Method | CTL* | [ 0 to 3 / 0 / 1] |
5-816-104 | Remote Service | Client Communication Limit | CTL* | [ 1 to 7 / 7 / 1] |
5-816-200 | Remote Service | Manual Polling | CTL | [ 0 to 1 / 0 / 1] |
5-816-201 | Remote Service | Regist Status | CTL* | [ 0 to 255 / 0 / 1] |
5-816-202 | Remote Service | Letter Number | CTL* | [ 0 to 0 / 0 / 0] |
5-816-203 | Remote Service | Confirm Execute | CTL | [ 0 to 1 / 0 / 1] |
5-816-204 | Remote Service | Confirm Result | CTL* | [ 0 to 255 / 0 / 1] |
5-816-205 | Remote Service | Confirm Place | CTL* | [ 0 to 1 / 0 / 0] |
5-816-206 | Remote Service | Register Execute | CTL | [ 0 to 1 / 0 / 1] |
5-816-207 | Remote Service | Register Result | CTL* | [ 0 to 255 / 0 / 1] |
5-816-208 | Remote Service | Error Code | CTL* | [ -2147483647 to 2147483647 / 0 / 0] |
5-816-209 | Remote Service | Instl Clear | CTL | [ 0 to 1 / 0 / 1] |
5-824-001 | NV-RAM Data Upload | CTL | [ 0 to 0 / 0 / 0] | |
5-825-001 | NV-RAM Data Download | CTL | [ 0 to 0 / 0 / 0] | |
5-849-001 | Installation Date | Display | CTL* | [ 0 to 0 / 0 / 0] |
5-858-001 | Collect Machine Info | 0:OFF 1:ON | CTL* | [ 0 to 1 / 1 / 1] |
5-858-101 | Collect Machine Info | Failure Occuring Date | CTL* | [ 0 to 20371212 / 0 / 1] |
5-858-102 | Collect Machine Info | Tracing Days | CTL* | [ 1 to 180 / 2 / 1day] |
5-858-141 | Collect Machine Info | Acquire All Debug Logs | CTL | [ -128 to 127 / 0 / 0] |
5-858-142 | Collect Machine Info | Acquire Controller Debug Logs Only | CTL | [ -128 to 127 / 0 / 0] |
5-858-143 | Collect Machine Info | Acquire Engine Debug Logs Only | CTL | [ -128 to 127 / 0 / 0] |
5-870-002 | Common KeyInfo Writing | Deletion | CTL | [ 0 to 1 / 0 / 1] |
5-875-001 | SC Auto Reboot | Reboot Setting | CTL* | [ 0 to 1 / 0 / 1] |
5-886-001 | Farm Update Setting | Permit ROM update | CTL* | [ 0 to 1 / 0 / 1] |
5-907-001 | Plug & Play Maker/Model Name | CTL* | [ 0 to 255 / 0 / 1] | |
5-911-001 | Auto Gap Adjustment | 8pass | CTL | [ 0 to 1 / 0 / 1] |
5-911-002 | Auto Gap Adjustment | 12pass | CTL | [ 0 to 1 / 0 / 1] |
5-911-004 | Auto Gap Adjustment | 16pass | CTL | [ 0 to 1 / 0 / 1] |
5-911-005 | Auto Gap Adjustment | 32pass | CTL | [ 0 to 1 / 0 / 1] |
5-911-007 | Auto Gap Adjustment | 12pass: W | CTL | [ 0 to 1 / 0 / 1] |
5-912-001 | Manual Gap Adjustment | 8pass | CTL | [ 0 to 1 / 0 / 1] |
5-912-002 | Manual Gap Adjustment | 12pass | CTL | [ 0 to 1 / 0 / 1] |
5-912-004 | Manual Gap Adjustment | 16pass | CTL | [ 0 to 1 / 0 / 1] |
5-912-005 | Manual Gap Adjustment | 32pass | CTL | [ 0 to 1 / 0 / 1] |
5-912-007 | Manual Gap Adjustment | 12pass: W | CTL | [ 0 to 1 / 0 / 1] |
5-913-001 | Auto Section Correction | 8pass | CTL | [ 0 to 1 / 0 / 1] |
5-913-002 | Auto Section Correction | 12pass | CTL | [ 0 to 1 / 0 / 1] |
5-913-003 | Auto Section Correction | H1Dfr:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-913-004 | Auto Section Correction | H1Dfr:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-913-006 | Auto Section Correction | 12pass: W | CTL | [ 0 to 1 / 0 / 1] |
5-913-007 | Auto Section Correction | H1Dfr:12pass: W | CTL | [ 0 to 1 / 0 / 1] |
5-914-001 | ManualSectionCorr:8pass | H1DfH1Bf:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-914-002 | ManualSectionCorr:8pass | H1DfH2Df:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-914-003 | ManualSectionCorr:8pass | H1DfH3Df:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-914-004 | ManualSectionCorr:8pass | H1DfH1Dr:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-914-005 | ManualSectionCorr:8pass | H1DfH1Br:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-914-006 | ManualSectionCorr:8pass | H2DfH2Bf:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-914-007 | ManualSectionCorr:8pass | H2DfH2Dr:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-914-008 | ManualSectionCorr:8pass | H2DfH2Br:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-914-009 | ManualSectionCorr:8pass | H3DfH3Bf:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-914-010 | ManualSectionCorr:8pass | H3DfH3Dr:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-914-011 | ManualSectionCorr:8pass | H3DfH3Br:8pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-001 | ManualSectionCorr:12pass | H1DfH1Bf:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-002 | ManualSectionCorr:12pass | H1DfH2Df:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-003 | ManualSectionCorr:12pass | H1DfH3Df:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-004 | ManualSectionCorr:12pass | H1DfH1Dr:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-005 | ManualSectionCorr:12pass | H1DfH1Br:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-006 | ManualSectionCorr:12pass | H2DfH2Bf:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-007 | ManualSectionCorr:12pass | H2DfH2Dr:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-008 | ManualSectionCorr:12pass | H2DfH2Br:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-009 | ManualSectionCorr:12pass | H3DfH3Bf:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-010 | ManualSectionCorr:12pass | H3DfH3Dr:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-915-011 | ManualSectionCorr:12pass | H3DfH3Br:12pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-001 | ManualSectionCorr:16pass | H1DfH1Bf:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-002 | ManualSectionCorr:16pass | H1DfH2Df:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-003 | ManualSectionCorr:16pass | H1DfH3Df:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-004 | ManualSectionCorr:16pass | H1DfH1Dr:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-005 | ManualSectionCorr:16pass | H1DfH1Br:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-006 | ManualSectionCorr:16pass | H2DfH2Bf:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-007 | ManualSectionCorr:16pass | H2DfH2Dr:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-008 | ManualSectionCorr:16pass | H2DfH2Br:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-009 | ManualSectionCorr:16pass | H3DfH3Bf:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-010 | ManualSectionCorr:16pass | H3DfH3Dr:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-917-011 | ManualSectionCorr:16pass | H3DfH3Br:16pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-001 | ManualSectionCorr:32pass | H1DfH1Bf:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-002 | ManualSectionCorr:32pass | H1DfH2Df:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-003 | ManualSectionCorr:32pass | H1DfH3Df:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-004 | ManualSectionCorr:32pass | H1DfH1Dr:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-005 | ManualSectionCorr:32pass | H1DfH1Br:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-006 | ManualSectionCorr:32pass | H2DfH2Bf:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-007 | ManualSectionCorr:32pass | H2DfH2Dr:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-008 | ManualSectionCorr:32pass | H2DfH2Br:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-009 | ManualSectionCorr:32pass | H3DfH3Bf:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-010 | ManualSectionCorr:32pass | H3DfH3Dr:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-918-011 | ManualSectionCorr:32pass | H3DfH3Br:32pass | CTL | [ 0 to 1 / 0 / 1] |
5-920-001 | ManualSectionCorr:12pass:W | H1DfH1Bf:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-920-002 | ManualSectionCorr:12pass:W | H1DfH2Df:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-920-003 | ManualSectionCorr:12pass:W | H1DfH3Df:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-920-004 | ManualSectionCorr:12pass:W | H1DfH1Dr:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-920-005 | ManualSectionCorr:12pass:W | H1DfH1Br:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-920-006 | ManualSectionCorr:12pass:W | H2DfH2Bf:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-920-007 | ManualSectionCorr:12pass:W | H2DfH2Dr:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-920-008 | ManualSectionCorr:12pass:W | H2DfH2Br:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-920-009 | ManualSectionCorr:12pass:W | H3DfH3Bf:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-920-010 | ManualSectionCorr:12pass:W | H3DfH3Dr:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-920-011 | ManualSectionCorr:12pass:W | H3DfH3Br:12pass:W | CTL | [ 0 to 1 / 0 / 1] |
5-921-001 | Carriage Position Adjustment | Colorimetric Sensor Read Position | CTL | [ 0 to 1 / 0 / 1] |
5-922-001 | Measuring Head Inclination | Absolute | CTL | [ 0 to 1 / 0 / 1] |
5-922-002 | Measuring Head Inclination | Relative | CTL | [ 0 to 1 / 0 / 1] |
5-922-003 | Measuring Head Inclination | Measuring Sub Scan Deviation | CTL | [ 0 to 1 / 0 / 1] |
5-922-004 | Measuring Head Inclination | Manual:Absolute | CTL | [ 0 to 1 / 0 / 1] |
5-922-005 | Measuring Head Inclination | Manual:Measuring Sub Scan Deviation | CTL | [ 0 to 1 / 0 / 1] |
5-923-001 | Test Chart | Forward-Backward Feed Offset | CTL | [ 0 to 1 / 0 / 1] |
5-923-002 | Test Chart | Main Scan Printing Position Adjustment | CTL | [ 0 to 1 / 0 / 1] |
5-923-003 | Test Chart | 2by2: 12pass | CTL | [ 0 to 1 / 0 / 1] |
5-923-004 | Test Chart | 2by2: 6pass | CTL | [ 0 to 1 / 0 / 1] |
5-923-005 | Test Chart | Sub Scan Adjustment: Base: H1D | CTL | [ 0 to 1 / 0 / 1] |
5-923-006 | Test Chart | Sub Scan Adjustment: Base: H1D BCD | CTL | [ 0 to 1 / 0 / 1] |
5-923-007 | Test Chart | Main Scan Adjustment | CTL | [ 0 to 1 / 0 / 1] |
5-923-008 | Test Chart | Grid Pattern | CTL | [ 0 to 1 / 0 / 1] |
5-924-001 | Sub Scan Position Adjustment | Transport Speed: Standard | CTL | [ 0 to 1 / 0 / 1] |
5-924-002 | Sub Scan Position Adjustment | Transport Speed: High | CTL | [ 0 to 1 / 0 / 1] |
5-924-003 | Sub Scan Position Adjustment | Transport Speed: Low | CTL | [ 0 to 1 / 0 / 1] |
5-925-001 | Auto Feed Adjustment | Roller | CTL | [ 0 to 1 / 0 / 1] |
5-925-002 | Auto Feed Adjustment | Transport Speed: Standard | CTL | [ 0 to 1 / 0 / 1] |
5-925-003 | Auto Feed Adjustment | Transport Speed: High | CTL | [ 0 to 1 / 0 / 1] |
5-925-004 | Auto Feed Adjustment | Transport Speed: Low | CTL | [ 0 to 1 / 0 / 1] |
5-925-009 | Auto Feed Adjustment | Forward/Backward Adjustment | CTL | [ 0 to 1 / 0 / 1] |
5-931-001 | Test Print: Nozzle Check | NozzleCheckWF1:W/O White | CTL | [ 0 to 1 / 0 / 1] |
5-931-003 | Test Print: Nozzle Check | NozzleCheckWF1:Factory:W/O White | CTL | [ 0 to 1 / 0 / 1] |
5-931-004 | Test Print: Nozzle Check | NozzleCheckWF2:Factory:W/O White | CTL | [ 0 to 1 / 0 / 1] |
5-932-001 | Test Print: Head Joint | Head Joint Correction Pattern | CTL | [ 0 to 1 / 0 / 1] |
5-933-002 | Test Print: Feed Joint | Feed Joint Correction Pattern | CTL | [ 0 to 1 / 0 / 1] |
5-934-001 | Test Print: Arrival | Arrival Chart (Fast Draft) | CTL | [ 0 to 1 / 0 / 1] |
5-935-001 | Test Print: Discharge State | Confirmation Chart (WF1 Large Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-935-002 | Test Print: Discharge State | Confirmation Chart (WF1 Middle Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-935-003 | Test Print: Discharge State | Confirmation Chart (WF1 Small Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-935-004 | Test Print: Discharge State | Confirmation Chart (WF2 Large Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-935-005 | Test Print: Discharge State | Confirmation Chart (WF2 Middle Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-935-006 | Test Print: Discharge State | Confirmation Chart (WF2 Small Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-936-001 | Test Print: Density Adjustment | Density Adjustment WF1 (Large Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-936-002 | Test Print: Density Adjustment | Density Adjustment WF1 (Middle Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-936-003 | Test Print: Density Adjustment | Density Adjustment WF1 (Small Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-936-004 | Test Print: Density Adjustment | Density Adjustment WF2 (Large Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-936-005 | Test Print: Density Adjustment | Density Adjustment WF2 (Middle Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-936-006 | Test Print: Density Adjustment | Density Adjustment WF2 (Small Drops) | CTL | [ 0 to 1 / 0 / 1] |
5-937-001 | Test Print: Crosstalk Correct | Crosstalk Correct WF1 H1 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-002 | Test Print: Crosstalk Correct | Crosstalk Correct WF1 H1 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-003 | Test Print: Crosstalk Correct | Crosstalk Correct WF1 H1 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-004 | Test Print: Crosstalk Correct | Crosstalk Correct WF1 H2 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-005 | Test Print: Crosstalk Correct | Crosstalk Correct WF1 H2 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-006 | Test Print: Crosstalk Correct | Crosstalk Correct WF1 H2 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-007 | Test Print: Crosstalk Correct | Crosstalk Correct WF1 H3 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-008 | Test Print: Crosstalk Correct | Crosstalk Correct WF1 H3 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-009 | Test Print: Crosstalk Correct | Crosstalk Correct WF1 H3 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-010 | Test Print: Crosstalk Correct | Crosstalk Correct WF2 H1 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-011 | Test Print: Crosstalk Correct | Crosstalk Correct WF2 H1 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-012 | Test Print: Crosstalk Correct | Crosstalk Correct WF2 H1 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-013 | Test Print: Crosstalk Correct | Crosstalk Correct WF2 H2 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-014 | Test Print: Crosstalk Correct | Crosstalk Correct WF2 H2 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-015 | Test Print: Crosstalk Correct | Crosstalk Correct WF2 H2 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-016 | Test Print: Crosstalk Correct | Crosstalk Correct WF2 H3 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-017 | Test Print: Crosstalk Correct | Crosstalk Correct WF2 H3 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-937-018 | Test Print: Crosstalk Correct | Crosstalk Correct WF2 H3 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-938-001 | Auto Joint Setting | Select Head Joint Pattern | CTL | [ 0 to 1 / 0 / 1] |
5-938-002 | Auto Joint Setting | Select Feed Joint Pattern | CTL | [ 0 to 1 / 0 / 1] |
5-939-001 | Clogged Nozzle Setting | Clogged Nozzle Auto Detection | CTL | [ 0 to 1 / 0 / 1] |
5-940-001 | Auto Density Adjustment | WF1 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-940-002 | Auto Density Adjustment | WF1 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-940-003 | Auto Density Adjustment | WF1 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-940-004 | Auto Density Adjustment | WF2 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-940-005 | Auto Density Adjustment | WF2 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-940-006 | Auto Density Adjustment | WF2 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-001 | Crosstalk Auto Correct | WF1 H1 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-002 | Crosstalk Auto Correct | WF1 H1 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-003 | Crosstalk Auto Correct | WF1 H1 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-004 | Crosstalk Auto Correct | WF1 H2 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-005 | Crosstalk Auto Correct | WF1 H2 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-006 | Crosstalk Auto Correct | WF1 H2 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-007 | Crosstalk Auto Correct | WF1 H3 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-008 | Crosstalk Auto Correct | WF1 H3 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-009 | Crosstalk Auto Correct | WF1 H3 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-010 | Crosstalk Auto Correct | WF2 H1 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-011 | Crosstalk Auto Correct | WF2 H1 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-012 | Crosstalk Auto Correct | WF2 H1 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-013 | Crosstalk Auto Correct | WF2 H2 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-014 | Crosstalk Auto Correct | WF2 H2 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-015 | Crosstalk Auto Correct | WF2 H2 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-016 | Crosstalk Auto Correct | WF2 H3 Large Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-017 | Crosstalk Auto Correct | WF2 H3 Middle Drops | CTL | [ 0 to 1 / 0 / 1] |
5-941-018 | Crosstalk Auto Correct | WF2 H3 Small Drops | CTL | [ 0 to 1 / 0 / 1] |
5-992-001 | SP Text Mode | All (Data List) | CTL | [ 0 to 255 / 0 / 0] |
5-992-002 | SP Text Mode | SP (Mode Data List) | CTL | [ 0 to 255 / 0 / 0] |
5-992-003 | SP Text Mode | User Program | CTL | [ 0 to 255 / 0 / 0] |
5-992-004 | SP Text Mode | Logging Data | CTL | [ 0 to 255 / 0 / 0] |
5-992-005 | SP Text Mode | Diagnostic Report | CTL | [ 0 to 255 / 0 / 0] |