1. Enter the SP mode.
  2. You can print out the PM counter list as follows.

    1. In the SP mode menu, press [PM Counter / New Unit Set].

    2. Press [Counterlist print out].

    3. Press [EXECUTE] to output the PM counter list.

    4. Press [Exit].

  3. In the SMC data, check the values of the counters in SP 7-621-002 to 208, to determine what parts should be replaced. (Refer to the SP table in the appendix.)

  4. In the SP mode menu, press [PM Counter / New Unit Set].
  5. Press [All PM Parts List : New Unit Set].
  6. Set the PM part that you want to replace to "YES" under "New Unit Set".
    After pressing "YES", the [Exit] key will not be available.
  7. Turn OFF the power and unplug the power cord.
  8. Replace the PM parts and turn ON the power.
    The machine will reset the PM counters automatically. In the case of the development unit, developer initialization will also be done automatically.
  9. Exit the SP mode.