| SP No. | Large Category | Small Category | ENG or CTL | [Min to Max / Init. / Step] | 
|---|
| 6-006-001 | ADF Adjustment | Side-to-Side Regist:Face | ENG* | [-3 to 3 / 0 / 0.1mm] | 
| 6-006-002 | ADF Adjustment | Side-to-Side Regist:Back | ENG* | [-2 to 2 / 0 / 0.1mm] | 
| 6-006-010 | ADF Adjustment | L-Edge Regist (1-Pass):Face | ENG* | [-5 to 5 / 0 / 0.1mm] | 
| 6-006-011 | ADF Adjustment | L-Edge Regist (1-Pass):Back | ENG* | [-5 to 5 / 0 / 0.1mm] | 
| 6-006-014 | ADF Adjustment | T-Edge Erase (1-Pass):Face | ENG* | [-5 to 5 / -1.6 / 0.1mm] | 
| 6-006-015 | ADF Adjustment | T-Edge Erase (1-Pass):Back | ENG* | [-5 to 5 / -1.6 / 0.1mm] | 
| 6-009-001 | ADF Free Run | Simplex Mode | ENG | [0 to 1 / 0 / 1STEP] | 
| 6-009-002 | ADF Free Run | Duplex Mode | ENG | [0 to 1 / 0 / 1STEP] | 
| 6-011-009 | 1-Pass ADF INPUT Check  | Original Detection | ENG | [0 to 1 / 0 / 1STEP] | 
| 6-011-010 | 1-Pass ADF INPUT Check  | Feed After sensor | ENG | [0 to 1 / 0 / 1STEP] | 
| 6-011-013 | 1-Pass ADF INPUT Check  | Registration Sensor | ENG | [0 to 1 / 0 / 1STEP] | 
| 6-011-015 | 1-Pass ADF INPUT Check  | Feed Cover Sensor | ENG | [0 to 1 / 0 / 1STEP] | 
| 6-011-024 | 1-Pass ADF INPUT Check  | Page Keeper Sensor | ENG | [0 to 1 / 0 / 1] | 
| 6-012-003 | 1-Pass ADF OUTPUT Check | Motor Forward | ENG | [0 to 1 / 0 / 1STEP] | 
| 6-012-004 | 1-Pass ADF OUTPUT Check | Motor Reverse | ENG | [0 to 1 / 0 / 1STEP] | 
| 6-012-014 | 1-Pass ADF OUTPUT Check | Feed Clutch | ENG | [0 to 1 / 0 / 1STEP] | 
| 6-017-001 | ADF Adjustment Magnification |   | ENG* | [-5 to 5 / 0 / 0.1%] | 
| 6-018-001 | 1-Pass ADF OUTPUT Check | Back shading | ENG | [0 to 1 / 0 / 1STEP] | 
| 6-030-001 | DF Hinge | Hinge Open Counter | ENG* | [0 to 999999 / 0 / 1] | 
| 6-030-002 | DF Hinge | Hinge Open Counter State | ENG* | [0 to 1 / 0 / 1] | 
| 6-030-003 | DF Hinge | Hinge Open Counter Clear | ENG | [0 to 0 / 0 / 0] | 
| 6-040-001 | Page Keeper | Mount Select | ENG* | [0 to 1 / 0 / 1] | 
| 6-040-005 | Page Keeper | Clear Select | ENG* | [0 to 1 / 1 / 1] |