- Turn off the main power switch of the MFP and disconnect the power cord.
- After replacing, make sure that all disconnected harnesses are connected up again and secured in their clamps.
Remove the operation panel unit from the MFP.
- For details about how to remove the operation panel unit, refer to the service manual for the MFP.
- Remove the hinges [A] [B] from the operation panel.
- By factory default, the following switches of the DIP switch [A] on the micro computer board are set to ON: No.1, No.3, No.6 and No.7. When installing the operation panel unit, make sure that the DIP switch setting is correct for the MFP on which you are installing the panel.
- The correct DIP switch setting depends on the MFP. Note the DIP switch settings of the old operation panel unit before replacing, and apply the same settings to the new Smart Operation Panel. Below is example for DIP switch settings when the following switches are set to ON: No.1, No.3, No.6 and No.7 (This is the factory default setting of a service part)
- If the DIP switch setting is wrong, SC672 will be displayed.
- The DIP switch No.1 turns ON/OFF the SC reduction function. Change the setting when needed.
- 0 (OFF): The SC is displayed on the operation panel when SC672/SC673 occur.
- 1 (ON): If the error is caused by the software defect when SC672/SC673 occur, automatically reboot is performed and the SC is reset. If the error is caused by the hardware defect when SC672/SC673 occur, the SC is displayed on the operation panel.
- After replacing the operation panel unit, make sure that the latest version of the firmware is installed on the Smart Operation Panel. Update it if necessary (Updating the Smart Operation Panel).