Ring Binder
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-01 |
D |
Ring Binder: Downstream device communication error |
- |
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-02 |
D |
Ring Binder: Device connection order error |
The ring binder did not detect the fixed device connection information command at the initial communication. |
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-10 |
D |
Ring Binder: Junction gate abnormal |
Junction gate failed to move out of the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor could not detect the junction gate within the prescribed time (600 pulses). The first occurrence triggers a jam, the second an SC code.
|
Path JG motor (M201) defective
Motor overloaded
Connector loose, broken, defective
JG HP sensor (S203) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-20 |
B |
Ring Binder: Pre-punch side fence HP error |
Thee sensor failed to detect that the component had moved out of the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor could not detect the component within the prescribed time (600 pulses). The first occurrence triggers a jam, the second an SC code.
|
Side jogger motor (M302) defective
Motor overloaded
Connector loose, broken, defective
Pre-punch jogger HP sensor (S302) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-21 |
B |
Ring Binder: Pre-punch jogger roller HP sensor |
The sensor failed to detect that the component had moved out of the home position within the prescribed time (36 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor could not detect the component within the prescribed time (22 pulses). The first occurrence triggers a jam, the second an SC code.
|
Jog roller lift motor (M305) defective
Motor overloaded
Connector loose, broken, defective
Jog roller lift HP sensor defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-22 |
B |
Ring Binder: Ring binder punch defective |
Punch unit was not detected at unit initialization.
The HP sensor was still detected within 30 ms after the DC motor switched ON and made one revolution.
An encoder pulse was not detected within 5 ms after the DC motor switched ON and made one revolution at home position.
The HP sensor was not detected within 400 ms after the DC motor switched ON.
|
Punch motor (M304) defective
Connector loose, broken, defective
Motor overload
Punch HP sensor (S302) defective
Punch encoder sensor defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-30 |
B |
Ring Binder: Paddle roller HP error |
When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
|
Paddle roller lift motor (M603) defective
Motor overloaded
Connector loose, broken, defective
Paddle roller HP sensor defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-31 |
B |
Ring Binder: Jogger fence 1 error |
When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
|
Jog fence 1 motor (M604) defective
Connector loose, broken, defective
Motor overload
Side fence 1 HP sensor (S601) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-32 |
B |
Ring Binder: Jogger fence 2 error |
When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
|
Jog fence 2 motor (M606) defective
Connector loose, broken, defective
Motor overload
Side fence 2 HP sensor (S611) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-33 |
B |
Ring Binder: Stack tamper HP error |
When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
|
Stack tamper motor (M607) defective
Motor overloaded
Connector loose, broken, defective
Stack tamper HP sensor (S612) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-34 |
B |
Ring Binder: Pre-bind jogger clamp HP error |
When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
|
Spine clamp motor (M605) defective
Motor overloaded
Connector loose, broken, defective
HP sensor (S603) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-40 |
B |
Ring Binder: Binder unit run-out error |
When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
|
Run-out press roller motor (M610) defective
Motor overloaded
Connector loose, broken, defective
Run-out roller HP sensor (S614) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-41 |
B |
Ring Binder: Clamp thickness error |
During jogging a 100-sheet stack was detected and the 50-sheet detect sensor (S606) went OFF. (1st detection signals a jam, 2nd detection issues this SC code.)
When the clamp moved to the open release position at initialization, the 50-sheet detect sensor went OFF.
|
50-sheet detect sensor (S606) defective
Connector loose, broken, defective
|
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-42 |
B |
Ring Binder: Alignment pin error |
When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
|
Alignment pin motor (M602) defective
Motor overloaded
Connector loose, broken, defective
Alignment pin HP sensor (S604) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-43 |
B |
Ring Binder: Pre-bind jogger shutter error |
When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
|
Shutter motor (M608) defective
Motor overloaded
Connector loose, broken, defective
Shutter HP sensor 1 (S605) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-44 |
B |
Ring Binder: 50/100 clamp adjustment error |
When moving to the home position, the sensor could not detect the component at the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home position within the prescribed time (400 ms). The first occurrence triggers a jam, the second an SC code.
|
50/100 clamp adjustment motor (M702) defective
Connector loose, broken, defective
Motor overload
Ring switch HP sensor (S706) defective
Ring switch timing sensor (S707) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-45 |
B |
Ring Binder: Timing sensor interval error |
At initialization or ring binding, the ON or OFF time of the timing sensor exceeded 1500 ms (1st detection signals a jam, 2nd detection issues this SC code) |
Clamp unit motor (M701) defective
Connector loose, broken, defective
Motor overload
Bind timing sensor (S702) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-46 |
B |
Ring Binder: Clamp unit HP error |
At initialization or during ring binding, the unit did not arrive at home position within the prescribed time (1500 ms) (1st detection triggers a jam alert, 2nd detection issues this SC code).
The sensor failed to detect that the component had moved out of the home position within the prescribed time (1500 ms) (1st detection triggers a jam alert, 2nd detection issues this SC code).
|
Clamp unit motor (M701) defective
Connector loose, broken, defective
Motor overload
Clamp unit HP sensor (S701) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-47 |
B |
Ring Binder: Spine alignment error |
During alignment a home position timeout (400 ms) occurred twice during movement of the tip of the alignment pin (2nd attempt was within an additional 400 ms). |
Alignment pin motor (M602) defective
Connector loose, broken, defective
Alignment pin HP sensor (S604) defective
Alignment pin up sensor (S610) defective
Jog mechanism defective
Punch defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-48 |
B |
Ring Binder: Binder unit not detected |
Binder unit was not detected at initialization before operation. |
Connector loose, broken, defective
Drawer connector defective
|
Replace the connector
Reconnect the connector
Replace the board
For details about SC756-48, refer to Ring Binder Recognition: SC756-48 . |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-50 |
B |
Ring Binder: Output belt rotation error |
The sensor failed to detect that the component had moved out of the home position within the prescribed time (800 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor could not detect the component within the prescribed time (2300 pulses). The first occurrence triggers a jam, the second an SC code.
|
Output belt rotation motor (M403) defective
Connector loose, broken, defective
Motor overload
Output belt rotation HP sensor (S403) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-51 |
B |
Ring Binder: Output belt 1 HP error |
The sensor failed to detect that the component had moved out of the home position within the prescribed time (200 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor could not detect the component within the prescribed time (2125 pulses). The first occurrence triggers a jam, the second an SC code.
|
Output belt 1 motor (M401) defective
Connector loose, broken, defective
Motor overload
Output belt 1 HP sensor (S401) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-52 |
B |
Ring Binder: Output belt 2 HP error |
The sensor failed to detect that the component had moved out of the home position within the prescribed time (200 pulses). The first occurrence triggers a jam, the second an SC code.
The sensor could not detect the component within the prescribed time (3130 pulses). The first occurrence triggers a jam, the second an SC code.
|
Output belt 2 motor (M402) defective
Connector loose, broken, defective
Motor overload
Output belt 2 HP sensor (S402) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-60 |
B |
Ring Binder: Stack height error |
The height of the stack increases until the stack height sensor goes ON. The sensor did not go ON within 6 sec. after the motor went ON (1st detection triggers a jam alert, 2nd detection issues this SC code). |
Stacker motor (M501) defective
Connector loose, broken, defective
Motor overload
Stack height sensor 1 (S502) defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC756-61 |
B |
Ring Binder: Stacker error |
At the start of stacking, or the end of the operation, even though the unit signaled stack full (stack up/down sensors went ON together), no stack was detected.
When stacking stopped, no stack was detected within 2 sec., even after the stack full alert. (1st detection triggers a jam, 2nd detection issues this SC code.)
|
Stacker HP sensor (S501) defective
Stack height sensor 1 (S502) defective
Stacker document sensor (S504) defective
Connector, loose, broken, defective
|
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
|