Skip header
 

Perfect Binder

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-01

D

Perfect Binder: Communication error with downstream peripheral

  • Break continued for 10 seconds or longer.

  • Anther STN was received during frame receipt.

  • No response even after resending 3 times.

  • Relay board defective, connector loose, broke, defective

  • Reconnect the connector.

  • Replace the relay board.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-10

D

Perfect Binder: Master-to-slave communication error 1

Master control board could not communicate with the slave control board for over 5 sec. and issued the communication alarm.

  • Master control board defective.

  • Slave Control Board defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the master control board.

  • Replace the slave control board.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-11

D

Perfect Binder: Master-to-slave communication error 2

Slave control board could not communicate with the master control board for over 5 sec. and issued the communication alarm.

  • Master control board defective.

  • Slave Control Board defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the master control board.

  • Replace the slave control board.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-12

D

Perfect Binder: Master-to-relay board communication error

  • IPU not "READY"

  • IPU occupancy not obtained

  • IPU detected an error

  • Master control board defective.

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the relay board.

  • Replace the master control board.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-13

D

Perfect Binder: Slave-to-cutter control board communication error 1

Slave control board could not communicate with the cutter control board (it detected the communication alarm for over 5 sec.).

  • Slave Control Board defective

  • Cutter control board defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the slave control board.

  • Replace the cutter control board.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-14

D

Perfect Binder: Slave-to-cutter control board communication error 2

Cutter control board could not communicate with the slave control board and detected the communication alarm for over 5 sec.

  • Slave Control Board defective

  • Cutter control board defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the slave control board.

  • Replace the cutter control board.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-15

D

Perfect Binder: Master EEPROM Read Error

Data written to the EEPROM does not match data read from the EEPROM

  • EEPROM defective

  • Replace the master control board EEPROM

  • Replace the master control board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-16

D

Perfect Binder: Master EEPROM write error

When data was written to the EEPROM, the EEPROM signaled that it was busy for longer than 25 ms and did not recover.

  • EEPROM defective

  • EEPROM not installed

  • Install the master control board EEPROM

  • Replace the master control board EEPROM

  • Replace the master control board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-17

D

Perfect Binder: Master-to-inserter initial communication error

After the ConfigSet (parallel signal) went ON while the inserter connection status was being checked, the initialization did not end successfully within 5 sec.

  • Inserter board defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the master control board.

  • Replace the inserter board.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-18

D

Perfect Binder: Master-to-Inserter Board Communication Error

No response to the specified command during the timeout. There was an overflow in memory where information required for paper feed is stored. (Master control board detection.)

  • Communication error at inserter

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the master control board.

  • Replace the inserter board.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-19

D

Perfect Binder: Software matching error

The IDs for the relay software of the master, slave, cutter, inserter devices do not match.

  • Software write failure

  • Download the software.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-20

D

Perfect Binder: 24V Check Signal Error 1

The 24V1 monitor signal of the master control board did not go off even though the front door switch was closed.

(Relay circuit failed to go ON.)

  • Front door L/R SW defective

  • Master control board defective.

  • Reconnect the connector.

  • Replace the front door L/R SW.

  • Replace the master control board.

  • Replace the sensor harness

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-21

D

Perfect Binder: 24V Check Signal Error 2

Top cover switch open or the 24V2 monitoring signal of master controller lost power for more than 5 sec, regardless of the status of the front door L/RWS and top cover sensor.

(Top cover sensor, or top cover switch is faulty.)

  • Front door L/RSW defective

  • Top cover switch defective

  • Top cover sensor defective

  • Master board defective

  • Reconnect the connector.

  • Replace the front door L/RSW.

  • Replace the top cover switch

  • Replace the top cover sensor.

  • Replace the master control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-22

D

Perfect Binder: 24V Check Signal Error 3

The 24V2 check signal of the slave control board failed to go OFF within 5 sec. even though the front door and top cover are closed.

  • Front door L/RSW defective

  • Top cover switch defective

  • Top cover sensor defective

  • Master board defective

  • Reconnect the connector.

  • Replace the front door L/RSW.

  • Replace the Top cover switch

  • Replace the topcover sensor.

  • Replace the slave board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-23

D

Perfect Binder: 24V Check Signal Error 4

The 24V3 check signal of the slave control board failed to go OFF within 5 sec., regardless of the status of the front door (monitored by the master control board).

  • Front door L/RSW defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the front door L/RSW

  • Replace the slave board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-24

D

Perfect Binder: Power supply fan (right) lock error

Right power supply fan failed to generate a lock signal within 12 sec., and signal could be detected even after a re-try.

  • Right power supply fan overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the right power supply fan

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-25

D

Perfect Binder: Power supply fan (center) lock error

See SC750-24

  • Center power supply fan overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the center power supply fan

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-26

D

Perfect Binder: Left power supply fan lock error detected

See SC750-24

  • Left power supply fan overloaded, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the left power supply fan

  • Replace the master control board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-27

D

Perfect Binder: Spine plate fan (front) lock error

Front spine plate fan failed to generate a lock signal within 12 sec., and signal could be detected even after a re-try.

  • Front spine plate fan overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the front spine plate fan.

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-28

D

Perfect Binder: Spine plate lower fan (right) lock error

See SC750-27

  • Right lower spine plate fan overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the right lower spin plate fan.

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-29

D

Perfect Binder: Spine plate upper fan (front) lock error

See SC750-27

  • Front upper spine plate fan overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the front upper spine plate fan.

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-30

D

Perfect Binder: Spine plate upper fan (right) lock error

See SC750-27

  • Upper right spine plate fan overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the upper right spine plate fan.

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-31

D

Perfect Binder: Signature fan 2 (front) lock error

Front signature fan 2 failed to generate a lock signal within 12 sec., and signal could be detected even after a re-try.

  • Front signature fan 2 overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the front signature fan 2.

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-32

D

Perfect Binder: Signature fan 2 (rear) lock error

See SC750-31

  • Rear signature fan 2 overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the rear signature fan 2.

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-33

D

Perfect Binder: Signature fan 1 (front) lock error

See SC750-31

  • Front signature fan 1 overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the front signature fan 1.

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-34

D

Perfect Binder: Signature fan 1 (rear) lock error

See SC750-31

  • Rear signature fan 1 overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the rear signature fan 1.

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-35

D

Perfect Binder: Glue supply fan (high) lock error

Glue supply (high) fan failed to generate a lock signal within 12 sec., and signal could be detected even after a re-try.

  • Glue supply fan (high) overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the glue supply fan (high).

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-36

D

Perfect Binder: Glue supply fan L lock error

Glue supply L fan failed to generate a lock signal within 12 sec., and signal could be detected even after a re-try.

  • Glue supply fan L overloaded, defective

  • Slave Control Board defective

  • Reconnect the connector.

  • Replace the glue supply fan L.

  • Replace the slave board.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-37

D

Perfect Binder: Grip HP sensor lag error

During operation of the grip unit the HP sensor did not OFF after grip unit moved 20 mm.

  • Grip motor defective, grip HP sensor defective, overload, sensor flag defective, connector broken defective

  • Reconnect the connector.

  • Replace the grip motor.

  • Replace the grip HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-38

D

Perfect Binder: Grip HP sensor late error

The HP sensor did not go ON after the grip unit released the signature and moved 76 mm.

  • Grip motor defective, Grip end sensor defective

, overload, Sensor flag defective, connector broken defective

  • Reconnect the connector.

  • Replace the grip motor.

  • Replace the grip HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-39

D

Perfect Binder: Grip end sensor lag error

  • The grip end sensor did not go off after the grip unit released the signature and moved the prescribed distance.

  • The grip end sensor did not go off, even after the booklet had been released after moving 86 mm.

  • Grip motor defective, Grip end sensor defective, overload Sensor flag defective, connector broken defective

  • Reconnect the connector.

  • Replace the grip motor.

  • Replace the grip end sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-40

D

Perfect Binder: Grip end sensor late error

  • The grip end sensor did not go on, even after the booklet had been moved 86 mm.

  • The grip end sensor did not go on within 3.7 sec. after the book was gripped.

  • Grip motor defective, Grip end sensor defective, overload, Sensor flag defective, connector broken defective

  • Reconnect the connector.

  • Replace the grip motor.

  • Replace the grip end sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-41

D

Perfect Binder: Left trimming buffer HP sensor lag error

The left trimmings buffer HP sensor did not go OFF within 3 sec. after the trimmings buffer moved away from the sensor.

  • Trimmings buffer motor defective

Left trimmings buffer HP sensor defective, overload, connector broken defective, Buffer full of trimmings

  • Reconnect the connector.

  • Replace the trimming buffer motor.

  • Replace the left trimming buffer HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-42

D

Perfect Binder: Trimming buffer HP sensor late error

The left trimmings buffer HP sensor did not go OFF within 5 sec. after the trimmings buffer moved toward the sensor.

Trimmings buffer motor defective, Left trimmings buffer HP sensor defective, overload, connector broken defective, Buffer full of trimmings

  • Reconnect the connector.

  • Replace the trimming buffer motor.

  • Replace the left trimming buffer HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-43

D

Perfect Binder: Right trimming buffer HP sensor lag error

The right trimmings buffer HP sensor did not go OFF within 3 sec. after the trimmings buffer moved away from the sensor.

Trimmings buffer motor defective, Right trimmings buffer HP sensor defective, overload, connector broken defective, Buffer full of trimmings

  • Reconnect the connector.

  • Replace the trimming buffer motor.

  • Replace the right trimming buffer HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-44

D

Perfect Binder: Right trimming buffer HP sensor late error

The right trimmings buffer HP sensor did not go OFF within 5 sec. after the trimmings buffer moved toward the sensor.

Trimmings buffer motor defective, Right trimmings buffer HP sensor defective, overload, connector broken defective, Buffer full of trimmings

  • Reconnect the connector.

  • Replace the trimming buffer motor.

  • Replace the right trimming buffer HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-45

D

Perfect Binder: Trimmings buffer motor rotation error

No encoder lock input received within 50 ms during operation.

  • Trimmings buffer motor defective

  • Trimming buffer encoder sensor defective, overload, connector broken defective, buffer full of trimmings

  • Reconnect the connector.

  • Replace the trimming buffer motor.

  • Replace the trimming buffer encoder sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-46

D

Perfect Binder: Thrust plate operation error

The thrust press plate sensor did not go OFF after the trimmings buffer moved to the left for 3 sec. (blocked by jammed trimming scraps).

Trimmings buffer motor defective, Thrust plate sensor defective, overload, connector broken defective, buffer full of trimmings

  • Reconnect the connector.

  • Replace the trimming buffer motor.

  • Replace the thrust plate sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-47

D

Perfect Binder: Thrust plate retraction error

The paper press plate sensor did not go ON after the trimmings buffer moved to the right for 3 sec. (blocked by jammed trimming scraps)

Trimmings buffer motor defective, Thrust plate sensor defective, overload, connector broken defective, buffer full of trimmings.

  • Reconnect the connector.

  • Replace the trimming buffer motor.

  • Replace the thrust plate sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-48

D

Perfect Binder: Book collection buffer HP sensor error

The book collection buffer HP sensor did not go OFF within the time prescribed for release of the book in the book buffer.

Book buffer tray motor defective, Book collection buffer tray HP sensor defective, overload, connector broken defective, blocked by

paper scraps

  • Reconnect the connector.

  • Replace the book buffer tray motor.

  • Replace the book collection buffer tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-49

D

Perfect Binder: Book collection buffer tray HP sensor late error

The book collection buffer HP sensor did not go off even after the book buffer tray moved for 3 sec.

Book buffer tray motor defective, Book collection buffer tray HP sensor defective, overload, connector broken defective, blocked by

paper scraps

  • Reconnect the connector.

  • Replace the book buffer tray motor.

  • Replace the book collection buffer tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-50

D

Perfect Binder: Press HP sensor lag error

During press plate operation during trimming, the edge press plate HP sensor did not OFF after it had time to move the prescribed distance.

Edge press plate motor defective, Press HP sensor defective, overload, connector broken defective

  • Reconnect the connector.

  • Replace the edge press plate motor.

  • Replace the press HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-51

D

Perfect Binder: Edge press plate late error

  • Edge press plate sensor did not go ON within 15 sec. of edge press release.

  • The edge press plage motor stopped when the edge press plate HP sensor switched ON, but after it stopped the HP sensor went OFF.

  • Edge press plate motor defective, Press HP sensor defective, overload, disconnected

  • Edge press plate motor defective, Press end sensor defective, overload

  • Reconnect the connector.

  • Replace the edge press plate motor.

  • Replace the press HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-52

D

Perfect Binder: Press end sensor lag jam

After the press plate released the signature and moved the prescribed distance, the press end sensor did not go OFF.

Edge press plate motor defective, Press end sensor defective, overload, disconnected

  • Reconnect the connector.

  • Replace the edge press plate motor.

  • Replace the press end sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-53

D

Perfect Binder: Press end sensor late jam

  • The press end sensor did not go ON within 8 sec. after the press operation started

  • Operation stopped when the press end sensor went ON, but sensor went off after the operation stopped.

Edge press plate motor defective, Press end sensor defective, overload, disconnected, no data about book thickness received

  • Reconnect the connector.

  • Replace the edge press plate motor.

  • Replace the press end sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-54

D

Perfect Binder: Press limit sensor error

Press limit sensor signaled ON.

Press limit sensor signaled ON.

  • Reconnect the connector.

  • Replace the press limit sensor.

  • Replace the press HP sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-55

D

Perfect Binder: Slide HP sensor lag error

When the slide was raised, the slide HP sensor did not go OFF after it moved 180 mm.

Slide motor defective, slide HP sensor defective, overload, disconnected, book jam

  • Reconnect the connector.

  • Replace the slide motor.

  • Replace the slide HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-56

D

Perfect Binder: Slide HP sensor late error

The slide HP sensor did not go ON after the slide was lowered and had enough time to move 180 mm.

Slide motor defective, slide HP sensor defective, overload, disconnected, book jam

  • Reconnect the connector.

  • Replace the slide motor.

  • Replace the slide HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-57

D

Perfect Binder: Book rotation HP sensor (right) lag error

  • The book rotation HP sensor did not go OFF after the book was rotated 60 degrees.

  • The book rotation HP sensor did not go OFF after the book was rotated 30 degrees.

Book rotation motor 1 (right) defective, Book rotation HP sensor (right) defective, overload, disconnected, book jam

  • Reconnect the connector.

  • Replace the book rotation motor 1 (right)

  • Replace the book rotation HP sensor (right)

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-58

D

Perfect Binder: Book rotation HP sensor (right) late error

  • The book rotation HP 1 (right) sensor did not go ON after the book was rotated 440 degrees.

  • The book rotation HP 1 (right) sensor did not go ON after the book was rotated 400 degrees.

  • The book rotation HP 1 (right) sensor did not go ON after the book was rotated 360 degrees.

Book rotation motor 1 (right) defective, Book rotation HP sensor (right) defective, overload, disconnected, book jam

  • Reconnect the connector.

  • Replace the book rotation motor 1 (right)

  • Replace the book rotation HP sensor (right)

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-59

D

Perfect Binder: Book rotation HP sensor (left) lag error

  • The book rotation HP sensor 2 (right) did not go OFF after the book was rotated 50 degrees.

  • The book rotation HP sensor 2 (left) did not go OFF after the book was rotated 50 degrees toward the cutting position.

Book rotation motor 2 (left)defective, Book rotation HP sensor 2(left) defective, overload, disconnected, book jam

  • Reconnect the connector.

  • Replace the book rotation motor 2 (left).

  • Replace the book rotation HP sensor 2(left).

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-60

D

Perfect Binder: Book rotation HP sensor (left) late error

  • The book rotation HP 2 (left) sensor did not go ON after the book was rotated 400 degrees.

  • The book rotation HP 2 (left) sensor did not go ON after the book was rotated 360 degrees.

  • Before the book is rotated before cutting, the book rotation HP sensor 2 (left) did not go on, even after the book had been rotated twice the prescribed distance.

Book rotation motor 2 (left)defective, book rotation HP 2 (left) sensor defective, overload, disconnected, book jam

  • Reconnect the connector.

  • Replace the book rotation HP 2 (left) sensor.

  • Replace the book rotation HP sensor 2 (left).

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-61

D

Perfect Binder: Cutter front HP sensor lag error

  • At initialization, the blade did not leave the home position even after 20 mm of movement.

  • When the blade moved to the rear, the blade did not leave the home position after the length of time elapsed tof 10 mm of movement.

Cutter motor defective, Blade sensors 1, 2 defective, disconnected, overload

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensors 1, 2.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-62

D

Perfect Binder: Cutter rear HP sensor late error

When the blade was moved to the rear, it did not arrive at the home position after 122 mm of movement.

Cutter motor defective, Blade sensors 1, 2 defective, disconnected, overload

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensors 1, 2.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-63

D

Perfect Binder: Cutter rear HP sensor lag error

  • When the blade moved from the rear HP sensor, it did not leave the rear HP position after 20 mm of movement toward the front.

  • When the blade moved to the front, the blade did not leave the home position after the length of time elapsed for 10 mm of movement.

Cutter motor defective, Blade sensors 1, 2 defective, disconnected, overload

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensors 1, 2.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-64

D

Perfect Binder: Cutter front HP sensor lag error

When the blade is moved to the front, the blade did not return to blade sensor 1 after enough time had elapsed for the blade to move 122 mm.

Cutter motor defective, Blade sensors 1, 2 defective , disconnect, overload

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensors 1, 2.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-65

D

Perfect Binder: Cut end late error

  • During movement from front to rear during cutting, blade sensor 1 did not go ON after enough time had elapsed for the blade to move 61 mm.

  • During movement from front to rear during cutting, blade sensor 1 did not go ON after 10 sec. had elapsed.

Cutter motor defective, Blade sensors 1 defective, disconnected, overload. Blade is dull, not cutting efficiently.

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensors 1.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Replace the blade.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-66

D

Perfect Binder: Cut end lag error

  • During movement from rear to front during cutting, blade sensor 1 did not go OFF after enough time had elapsed for the blade to move 61 mm.

  • During movement from rear to front during cutting, blade sensor 1 did not go OFF after 10 sec. had elapsed.

Cutter motor defective, Blade sensors 1 defective, disconnected, overload. Blade is dull, not cutting efficiently.

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensors 1.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Replace the blade.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-67

D

Perfect Binder: Trimmer limit sensor error

Trimmer limit sensor signaled ON.

Trimmer limit sensor defective

Blade sensors 1, 2 defective , disconnect

  • Reconnect the connector.

  • Replace the Trimmer limit sensor.

  • Replace the blade sensors 1, 2.

  • Replace the cutter control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-68

D

Perfect Binder: Book lift tray HP sensor lag error

  • During tray lifting, the book tray lift sensor did not go off after 10 sec. had elapsed.

  • The book lift sensor did not go off after enough time had elapsed to move the tray more than 10 mm.

Book lift tray motor defective, Book lift tray HP sensor defective, disconnect, overload

  • Reconnect the connector.

  • Replace the book lift tray motor.

  • Replace the book lift tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-69

D

Perfect Binder: Book lift tray HP sensor late error

While the book lift tray was being lowered, the book lift tray HP sensor did not go on after 1.5 sec. had elapsed.

Book lift tray motor defective, Book lift tray HP sensor defective, disconnect, overload, Book jam, bundle drop

  • Reconnect the connector.

  • Replace the book lift tray motor.

  • Replace the book lift tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-70

D

Perfect Binder: Book lift tray motor rotation error

No encoder lock input received within 50 ms during operation.

  • Book lift tray motor defective,

  • Book lift tray encoder sensor defective, disconnect

  • Reconnect the connector.

  • Replace the book lift tray motor.

  • Replace the Book lift tray encoder sensor

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-71

D

Perfect Binder: Book output tray HP sensor lag error

  • The book output tray HP sensor did not go OFF within 1 sec. after it went ON.

  • The book output tray HP sensor did not go OFF after enough time had elapsed for the tray to move more than 10 mm.

Book output belt motor defective, Book output tray HP sensor defected, disconnect, overload

  • Reconnect the connector.

  • Replace the book output belt motor.

  • Replace the book output tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-72

D

Perfect Binder: Book out put tray HP sensor late error

The book output tray HP sensor did not go ON within 3.5 sec. after it went OFF.

Book output belt motor defective, Book output tray HP sensor defected, disconnect, overload

  • Reconnect the connector.

  • Replace the book output belt motor.

  • Replace the book output tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-73

D

Perfect Binder: Blade cradle HP sensor lag error

While the blade was retracting to the home position, the blade cradle sensor did not go OFF after enough time had elapsed for the blade to move 12 mm.

Blade cradle motor defective, Blade cradle sensor defective, disconnect, overload

  • Reconnect the connector.

  • Replace the blade cradle motor.

  • Replace the blade cradle HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-74

D

Perfect Binder: Blade cradle HP sensor late error

While the bladed was being lowered, the blade cradle HP sensor did not go ON after enough time had elapsed for 21 mm of movement.

Blade cradle motor defective, the blade cradle HP sensor defective, disconnect, overload, blade cradle or cutter physically jammed by obstacle

  • Reconnect the connector.

  • Replace the blade cradle motor.

  • Replace the blade cradle HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Remove the blade and the edge press plate.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-75

D

Perfect Binder: Book door lock error

The book door sensor was detected OFF with the book door locked.

Book door lock solenoid defective, Book door sensor defective, disconnect

  • Reconnect the connector.

  • Replace the book door lock solenoid.

  • Replace the book door sensor.

  • Replace the cutter control board.

  • Replace the SOL harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-76

D

Perfect Binder: Glue heater error

The glue heater thermistor registered more that 200 degrees for more than 1 sec.

  • Glue temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-77

D

Perfect Binder: Electrical short in the gluing unit

A temperature of less than 5 degrees was detected for 1 sec. or more than 10 sec. after power on.) However, if the thermistor detected less than 100 degrees after measuring temperature at start up, temperature is checked again after 50 sec.

  • Glue temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-78

D

Perfect Binder: Glue heater startup error 1

Glue temperature thermistor did not detect a temperature of 140 degrees within 200 sec. after it detected a temperature over 50 degrees.

  • Glue temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-79

D

Perfect Binder: Low temperature detection error

After adjustment of the glue temperature, the glue temperature thermistor detected a temperature lower than 135 degrees for more than 10 sec.

  • Glue temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-80

D

Perfect Binder: High temperature error

Thermistor detected abnormal high temperature.

  • Glue abnormal temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-81

D

Perfect Binder: Thermostat error

Abnormal thermostat detection.

  • Thermostat defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-82

D

Perfect Binder: Glue level thermistor error 1

After glue warm-up completed, the glue level thermistor detected a temperature of over 170 degrees for more than10 sec.

  • Glue level thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-83

D

Perfect Binder: Glue level thermistor error 2

After glue warm-up completed, the glue level thermistor detected a temperature less than 100 degrees for more than10 sec.

  • Glue level thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-84

D

Perfect Binder: Thermistor disconnect error

The glue abnormal temperature thermistor detected a temperature of less than 5 degrees for 1 sec., or more than 10 sec. after power on. However, if the thermistor detected less than 100 degrees after measuring temperature at start up, temperature is checked again after 50 sec.

  • Glue abnormal temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-85

D

Perfect Binder: Glue level thermistor disconnect error

The AD value of the glue level thermistor was above 991 LSB for 10 sec. Temperature adjustment mode stops if glue level sensor detects the temperature remaining below 99 degrees for more than 10 sec.

  • Glue level thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-86

D

Perfect Binder: Internal temperature thermostat error

The A/D value of the internal temperature thermostat was detected above 80 degrees for 1 sec.

Internal temperature thermistor defective, Slave board defective

  • Reconnect the connector.

  • Replace the internal temperature thermistor.

  • Replace the slave board.

  • Replace the thermistor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-87

D

Perfect Binder: Internal temperature thermostat disconnect error

The A/D value of the internal temperature thermostat was detected below -20 degrees for 1 sec.

Internal temperature thermistor defective, Slave board defective

  • Reconnect the connector.

  • Replace the internal temperature thermistor.

  • Replace the slave board.

  • Replace the thermistor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-88

D

Perfect Binder: Internal temperature thermostat error

Temperature was detected above 10C three consecutive times (sampled every sec. for 1 min.).

Internal temperature thermistor defective, Slave board defective

  • Reconnect the connector.

  • Replace the internal temperature thermistor.

  • Replace the slave board.

  • Replace the thermistor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC750-89

D

Perfect Binder: Glue heater startup error 2

The warm-up temperature was above the +-5C target for the glue vat temperature. (Not detected within 100 sec. after machine warm-up.)

  • Internal temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the internal temperature thermistor.

  • Replace the gluing unit.

  • Replace the slave board.

  • Replace the thermistor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-10

D

Glue heater startup error 3

The warm-up temperature was below the +-5C target for the glue vat temperature. (Not detected within 100 sec. after machine warm-up.)

  • Internal temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the internal temperature thermistor.

  • Replace the gluing unit.

  • Replace the slave board.

  • Replace the theristor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-11

D

Perfect Binder: Glue heater startup error 4

At the end of temperature adjustment at power on, warm-up did not complete within 500 sec. The glue vat temperature did not reach the warm-up temperature within 500 sec.

  • Glue heater connector loose, broken, defective

  • Heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-12

D

Perfect Binder: Ambient temperature error

Ambient temperature is not within the operational range: It was between 0°C and -20°C.

  • Internal temperature thermistor connector loose, broken, defective

  • Thermistor defective

  • Slave board defective

  • Reconnect the connector.

  • Check the room temperature (0°C or higher).

  • Replace the internal temperature thermistor.

  • Replace the slave board.

  • Replace the theristor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-13

D

Perfect Binder: Glue low limit late error

The level of the glue in the vat was detected below the low limit 4 times.

  • Glue clogged, glue supply defective

  • Glue level thermistor connector loose, broken, defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

  • Check the remaining amount of glue pellets.

  • Remove the clogged glue.

  • Check the gluing unit.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-14

D

Perfect Binder: Glue high limit late error

Without glue application, and with the glue level above the low limit, the glue level thermistor did not detect the level of the glue at the high limit, even after 12 glue pellets were supplied.

  • Glue clogged, glue supply defective

  • Glue level thermistor connector loose, broken, defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

  • Check the remaining amount of glue pellets.

  • Remove the clogged glue.

  • Check the gluing unit.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-15

D

Perfect Binder: Glue lowering level error

Without glue supply, the level of the glue detected by the glue lever thermistor did not lower away from the high limit level, even after application of 25.42 g.

  • Glue clogged, glue supply defective

  • Glue level thermistor connector loose, broken, defective

  • Thermistor defective

  • Slave board defective

  • Glue application defective

  • Reconnect the connector.

  • Adjust the amount of glue application.

  • Replace the gluing unit.

  • Replace the slave board.

  • Check the gluing unit.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-16


Perfect Binder: Glue level thermistor adjustment value error

  • Temperature detected by glue level thermistor out of range, 128°C+-14°C for low limit.

  • Temperature detected by glue level thermistor out of range, 142°C+-10°C for high limit.

  • The glue level thermistor adjustment value for low limit is larger than the high level.

  • Glue level thermistor target value is 5°C off the values of the low and high limit.

  • Master control board EEPROM defective

  • Glue level thermistor connector loose, broken, defective

  • Thermistor defective

  • Slave board disconnected, defective

  • Reconnect the connector.

  • Re-set the value for glue level thermistor.

  • Replace the gluing unit.

  • Replace the master control board EEPROM

  • Replace the slave board.

  • Replace the master control board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-17

D

Perfect Binder: Timing sensor adjustment high value error

The timing sensor A/D input value was lower than 3.0 to 3.5V, the A/D input value did not go higher than 3.0 to 3.5V, even after timing sensor D/A output value was higher than 3.5V.

  • Timing sensor connector loose, broken, defective

  • Sensor defective

  • Master control board disconnected, defective

  • Reconnect the connector.

  • Clean the sensor.

  • Replace the timing sensor.

  • Replace the master control board

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-18

D

Perfect Binder: Cover registration sensor adjustment high value error

The cover registration sensor A/D input value was lower than 3.0 to 3.5V, the A/D input value did not go higher than 3.0 to 3.5V, even after cover registration sensor output value output was higher than 3.5V.

  • Cover registration sensor connector loose, broken, defective

  • Sensor defective

  • Master control board disconnected, defective

  • Reconnect the connector.

  • Clean the sensor.

  • Replace the cover registration sensor.

  • Replace the master control board

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-19

D

Perfect Binder: Cover horizontal registration sensor (S) adjustment high value error

The cover horizontal registration sensor (S) A/D input value was lower than 3.2 to 3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after cover registration sensor (S) D/A output value output was higher than 3.7V.

  • Cover horizontal registration sensor (S) connector loose, broken, defective

  • Sensor defective

  • Slave control board defective

  • Reconnect the connector.

  • Clean the sensor.

  • Replace the cover horizontal registration sensor (S).

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-20

D

Perfect Binder: Cover horizontal registration sensor (L) adjustment high value error

The cover horizontal registration sensor (L) A/D input value was lower than 3.2 to 3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after cover horizontal registration sensor (L) D/A output value output was higher than 3.7V.

  • Cover horizontal registration sensor (L) connector loose, broken, defective

  • Sensor defective

  • Slave control board defective

  • Reconnect the connector.

  • Clean the sensor.

  • Replace the Cover horizontal registration sensor (L)

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-21

D

Perfect Binder: Signature exit sensor adjustment high value error

The signature exit sensor A/D input value was lower than 3.2 to 3.54V, the A/D input value did not go higher than 3.2 to 3.54V, even after cover registration sensor output value output was higher than 3.7V.

  • Signature exit sensor connector loose, broken, defective

  • Sensor defective

  • Slave control board disconnected, defective

  • Reconnect the connector.

  • Replace the signature exit sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-22

D

Perfect Binder: LE detect sensor adjustment high value error

The leading edge detect sensor A/D input value was lower than 3.2 to 3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after cover registration sensor A/D output value output was higher than 3.7V.

  • LE detect sensor connector loose, broken, defective

  • Sensor defective

  • Slave control board disconnected, defective

  • Reconnect the connector.

  • Replace the LE detect sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-23

D

Perfect Binder: Entrance path sensor adjustment high value error

When the entrance path sensor was adjusted, the sensor A/D input was less than 2.58 V, even after the sensor D/A output was more than 3.3V.

  • Entrance path sensor connector loose, broken, defective

  • Sensor defective

  • Cutter control board disconnected, defective

  • Reconnect the connector.

  • Replace the entrance path sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-24

D

Perfect Binder: Book registration sensor adjustment high value error

When the book registration sensor was adjusted, the sensor A/D input was less than 2.58 V, even after the sensor D/A output was more than 3.3V.

  • Book registration sensor connector loose, broken, defective

  • Cutter control board disconnected, defective

  • Reconnect the connector.

  • Replace the book registration sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-25

D

Perfect Binder: Timing sensor adjustment low value error

The timing sensor A/D input value was higher than 3.0 to 3.5V, the A/D input value did not enter the range 3.0 to 3.5V, even after timing sensor D/A output value was lower than 0.1V.

  • Timing sensor connector loose, broken, defective

  • Sensor defective

  • Master control board disconnected, defective

  • Reconnect the connector.

  • Replace the timing sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-26

D

Perfect Binder: Cover registration sensor adjustment low value error

The cover registration sensor A/D input value was higher than 3.0 to 3.5V, the A/D input value did not enter the range 3.0 to 3.5V, even after cover registration sensor D/A output value output was lowered 0.1V.

  • Cover registration sensor connector loose, broken, defective

  • Sensor defective

  • Master control board disconnected, defective

  • Reconnect the connector.

  • Replace the cover registration sensor.

  • Replace the master control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-27

D

Perfect Binder: Cover horizontal registration sensor (S) adjustment low value error

The cover horizontal registration sensor (S) A/D input value was higher than 3.2 to 3.54V, and the A/D input value did enter the range 3.2 to 3.54V, even sensor D/A output value output was lowered 0.04V.

  • Cover horizontal registration sensor (S) connector loose, broken, defective

  • Sensor defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the Cover horizontal registration sensor (S).

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-28

D

Perfect Binder: Cover horizontal registration sensor (L) adjustment low value error

The cover horizontal registration sensor (L) A/D input value was higher than 3.2 to 3.54V, and the A/D input value did enter the range 3.2 to 3.54V, even sensor D/A output value output was lowered 0.04V.

  • Cover horizontal registration sensor (L) connector loose, broken, defective

  • Sensor defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the cover horizontal registration sensor (L).

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-29

D

Perfect Binder: Signature exit sensor adjustment low value error

The signature exit sensor A/D input value was higher than 3.2 to 3.54V, the A/D input value did not enter the range 3.2 to 3.54V, even after cover registration sensor output value output was lowered 0.04V.

  • Signature exit sensor connector loose, broken, defective

  • Sensor defective

  • Slave control board disconnected, defective

  • Reconnect the connector.

  • Replace the signature exit sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-30

D

Perfect Binder: LE detect sensor adjustment low value error

The LE detect sensor A/D input value was higher than 3.2 to 3.54V, and the sensor A/D input value did not enter the range 3.2 to 3.54V, even after the sensor output value was raised 0.04V.

  • LE detect sensor connector loose, broken, defective

  • Sensor defective

  • Slave control board disconnected, defective

  • Reconnect the connector.

  • Replace the LE detect sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-31

D

Perfect Binder: Entrance path sensor adjustment low value error

When the entrance path sensor was adjusted, the sensor A/D input was higher than 2.58 V, even after the sensor D/A output was lowered to 0V.

  • Entrance path sensor connector loose, broken, defective

  • Sensor defective

  • Cutter control board disconnected, defective

  • Reconnect the connector.

  • Replace the entrance path sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-32

D

Perfect Binder: Book registration sensor adjustment low value error

When the book registration sensor was adjusted, the sensor A/D input was more than 2.58 V, even after the sensor D/A output was less than 0V.

  • Book registration sensor connector loose, broken, defective

  • Cutter control board disconnected, defective

  • Reconnect the connector.

  • Replace the book registration sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-33

D

Perfect Binder: LE detect sensor late error

The stack was late for gluing to the cover because there was no stack transport end sensor from the slave control board and there was no signal that the LE detect sensor had signaled to arrival of the stack.

LE detect sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the signature exit roller motor.

  • Replace the LE detect sensor.

  • Replace the slave control board.

  • Replace the cutter control board

  • Replace the motor harness.

  • Replace the sensor harness.

  • Replace the harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-34

D

Perfect Binder: Trim unit entrance sensor late error

The stack was late arriving because the trim unit entrance sensor did not go ON even after a transport end signal was received.

  • Trim unit entrance sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the signature exit roller motor.

  • Replace the entrance path sensor.

  • Replace the slave control board.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-35

D

Perfect Binder: Book registration sensor late error

At the start of cutter registration, the book registration did not go ON. The stack could not be detected for fore edge cutting.

  • Book registration sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the book registration sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-36

D

Perfect Binder: Signature exit sensor lag error

When the power was turned on, the cover path was closed and the signature exit sensor detected paper present, but the LE detect sensor had detected no paper present.

  • Signature exit sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the signature exit sensor.

  • Replace the LE detect sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-37

D

Perfect Binder: Entrance path sensor late error

During the automatic exit operation, the entrance path sensor could not detect any paper within 6860 ms after gluing and stack transport started.

  • Entrance path sensor connector loose, broken, defective

  • Sensor defective

  • Stack transport roller defective

  • Reconnect the connector.

  • Replace the signature exit roller motor.

  • Replace the entrance path sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-38

D

Perfect Binder: Main grip late error

There was no stack received from the sub grip unit; the main grip signature sensor detected no stack.

  • Main grip signature sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the signature movement motor.

  • Replace the main grip signature sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-39

D

Perfect Binder: Trim unit entrance sensor lag error

  • At the end of initialization at power on, the entrance path sensor went ON.

  • At the end of automatic exit, the entrance path sensor went ON.

  • Trim unit entrance sensor connector, loose, broken, defective

  • Reconnect the connector.

  • Replace the entrance path sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-40

D

Perfect Binder: Book registration sensor lag error

Book registration sensor:

  • Detected ON at the end of initialization after power on.

  • Detected ON at the end of automatic exit operation.

  • Detected ON at the end of book binding and automatic exit.

  • Could detect no stack at fore edge cutting.

  • Detected ON at end of grip operation during book binding.

  • Book registration sensor connector loose, broken, defective

  • Sensor defective at the lift tray

  • Reconnect the connector.

  • Replace the book registration sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-41

D

Perfect Binder: Book arrival sensor lag error

Not detected

  • Book arrival sensor connector loose, broken, defective

  • Sensor defective

  • Book failed to reach output tray

  • Fore edge trim scraps fell into output area

  • Not detected

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-42

D

Perfect Binder: Trimming jam error

  • The edge press plate HP sensor remained OFF after disposing of the trimmed paper and the trimmings buffer was moved 19 mm to the right.

  • After the trimmings buffer door was opened and closed tto check for paper scraps, the machine detected paper scrap jam 3 times (and issued the alarm after the 2nd detection).

  • There are scraps in the trimmings buffer and at the edge press plate

  • Edge press plate HP sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the trimming buffer motor.

  • Replace the edge press plate HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-43

D

Perfect Binder: Sub grip unit lag error

When the sub grip unit was checked for the presence of paper, no paper could be detected even after opening the sub grip unit.

  • Paper remains in the sub grip unit.

  • Sub grip paper sensor connector loose, broken, defective

  • Reconnect the connector.

  • Replace the SG motor.

  • Replace the sub grip paper sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-44

D

Perfect Binder: Main grip unit lag error

  • Although cutter retracted, the absence of paper could not be detected.

  • Paper remains in the main grip unit

  • Main grip signature sensor loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the main grip signature sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

  • Clear the signature jam.

  • Replace the signature exit roller motor.

  • Replace the motor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-45

D

Perfect Binder: Signature thickness sensor minimum value error

When the result of the signature thickness detection (A/D value) was adjusted, the minimum value (0 mm) was smaller than the A/D value of -30.

  • Signature thickness sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Specify the signature thickness again.

  • Replace the signature thickness sensor.

  • Replace the master control board EEPROM

  • Replace the slave control board.

  • Replace the master control board.

  • Replace the VR harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-46

D

Perfect Binder: Signature thickness sensor maximum value error

When the result of the signature thickness detection (A/D value) was adjusted, the maximum value (25mm) was smaller than the A/D value.

  • Sensor defective

  • Reconnect the connector.

  • Specify the signature thickness again.

  • Replace the signature thickness sensor.

  • Replace the master control board EEPROM

  • Replace the slave control board.

  • Replace the master control board.

  • Replace the VR harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-47

D

Perfect Binder: Signature thickness sensor value unstable error

The signature thickness reading did not change, even after the main grip unit opened and closed.

  • Signature thickness sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Specify the signature thickness again.

  • Replace the signature thickness sensor.

  • Replace the master control board EEPROM

  • Replace the slave control board.

  • Replace the master control board.

  • Replace the VR harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-48

D

Perfect Binder: Glue vat HP sensor late error

  • The glue vat HP sensor (rear) did not go ON when the glue vat roller motor initialized at power on and remained on for 4240 ms.

  • When the glue vat HP sensor (rear) moved from the HP to the front, the glue vat HP sensor was already OFF.

  • Glue vat roller motor connector loose, broken, defective

  • Motor defective

  • Glue vat HP sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the glue vat roller motor.

  • Replace the glue vat HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-49

D

Perfect Binder: Glue vat HP sensor lag error

The glue vat HP sensor did not go off when the glue vat moved to the front, even though the glue vat roller motor operated for 285 ms.

The glue vat HP sensor was already ON when the glue vat moved from the front to the rear.

  • Glue vat roller motor connector loose, broken, defective

  • Motor defective

  • Glue vat HP sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the glue vat roller motor.

  • Replace the glue vat HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-50

D

Perfect Binder: Glue vat roller motor error

The glue vat roller rotation sensor could not detect rotation of the glue vat roller motor within 1200 ms of motor operation.

  • Glue vat roller motor connector loose, broken, defective

  • Motor defective

  • Glue vat roller rotation sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the glue vat roller motor.

  • Replace the glue vat roller rotation sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-51

D

Perfect Binder: Glue roller HP sensor late error

During glue supply, the glue roller HP sensor did not go ON, even though the glue roller motor was operating for 1000 ms.

  • Glue supply motor connector loose, broken, defective

  • Motor defective

  • Glue pellets jammed

  • Glue roller HP sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the glue supply motor.

  • Replace the glue roller HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Remove the cause of jam (glue pellets).

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-52

D

Perfect Binder: Glue roller HP sensor lag error

During glue supply, the glue roller HP sensor did not go OFF, even though the glue roller motor was operating for 2400 ms.

  • Glue supply motor connector loose, broken, defective

  • Motor defective

  • Glue pellets jammed

  • Glue roller HP sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the glue supply motor.

  • Replace the glue roller HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Remove the cause of jam (glue pellets).

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-53

D

Perfect Binder: Spine fold HP sensor (L) late error

  • The spine fold HP sensor (left) did not go ON during spine folding, even after the spine fold motor (left) was operating for 5805 ms (or enough time elapsed for the plate to travel 101.24 mm).

  • When the spine fold plate moved from the open to closed position, the spine fold HP sensor (left) was already OFF.

  • Spine fold motor (L) connector loose, broken, defective

  • Motor defective

  • Spine fold HP sensor (L) connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine fold motor (L).

  • Replace the spine fold HP sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-54

D

Perfect Binder: Spine fold HP sensor (L) lag error

  • The spine fold (left) HP sensor did not go OFF when the spine fold plate closed, even while the spine fold motor (left) was operating for 500 ms.

  • When the spine fold plate moved from the close to open position, the spine fold HP sensor (left) was already ON.

  • Spine fold motor (L) connector loose, broken, defective

  • Motor defective

  • Spine fold HP sensor (L) connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine fold motor (L).

  • Replace the spine fold HP sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-55

D

Perfect Binder: Left spine fold plate close error

In the operation of the left spine fold plate, the left spine close sensor did not go ON, even after the left spine fold plate motor was on for 5805 ms, equivalent to the plate moving 101.25 mm.

When the spine fold plate moved from the closed to open position, the left spine close sensor was already OFF.

  • Spine fold motor (L) connector loose, broken, defective

  • Motor defective

  • Spine close sensor (L) connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine fold motor (L).

  • Replace the spine close sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-56

D

Perfect Binder: Left spine fold plate open error

In the operation of the left spine fold plate, the left spine close sensor did not go OFFN, even after the left spine fold plate motor was on for 500 ms.

When the spine fold plate moved from the open to closed position, the left spine close sensor was already ON.

  • Spine fold motor (L) connector loose, broken, defective

  • Motor defective

  • Spine close sensor (L) connector loose, broken, defective

  • Reconnect the connector.

  • Replace the spine fold motor (L).

  • Replace the spine close sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-57

D

Perfect Binder: Spine fold HP sensor (L) error

The spine fold HP sensor (L) and spine fold close sensor (L) went ON at the same time.

  • Spine fold HP sensor (L) connector loose, broken, defective

  • Sensor defective

  • Spine close sensor (L) connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine fold HP sensor (L).

  • Replace the spine close sensor (L).

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-58

D

Perfect Binder: Spine fold HP sensor (R) error

  • The spine fold HP sensor (right) did not go ON during operation of the right fold plate, even after the spine fold motor (right) was operating for 3225 ms (or enough time elapsed for the plate to travel 56.25mm).

  • When the spine fold plate moved from the open to closed position, the spine fold HP sensor (right) was already OFF.

  • Spine fold motor (R) connector loose, broken, defective

  • Motor defective

  • Spine fold HP sensor (R) connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine fold motor (R).

  • Replace the Spine fold HP sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-59

D

Perfect Binder: Spine fold HP sensor (R) lag error

  • The spine fold (right) HP sensor did not go OFF when the spine fold plate closed, even while the spine fold motor (right) was operating for 500 ms.

  • When the spine fold plate moved from the closed to open position, the spine fold HP sensor (right) was already ON.

  • Spine fold motor (R) connector loose, broken, defective

  • Motor defective

  • Spine fold HP sensor (R) connector loose, broken, defective.

  • Reconnect the connector.

  • Replace the spine fold motor (R).

  • Replace the spine fold HP sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-60

D

Perfect Binder: Right spine fold plate close error

The spine fold press sensor (right) did not go ON when the right fold plate was closing, even after the spine fold motor (right) was operating for 3225 ms (or enough time elapsed for the plate to travel 56.25mm).

When the spine fold plate moved from the closed to open position, the spine fold press sensor (right) was already OFF.

  • Spine fold motor (R) connector loose, broken, defective

  • Motor defective

  • Spine fold press sensor (R) connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine fold motor (R).

  • Replace the spine fold press sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-61

D

Perfect Binder: Right spine fold plate open error

  • The spine fold press sensor (right) did not go OFF when the spine fold plate closed, even while the spine fold motor (right) was operating for 500 ms.

  • When the spine fold plate moved from the open to open position, the spine fold press sensor (right) was already ON.

  • Spine fold motor (R) connector loose, broken, defective

  • Motor defective

  • Spine fold press sensor (R) connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine fold motor (R).

  • Replace the spine fold press sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-62

D

Perfect Binder: Spine fold HP sensor (R) error

The spine fold HP sensor (R) and spine fold press sensor (R) went ON at the same time.

  • Spine fold HP sensor (R) connector loose, broken, defective

  • Sensor defective

  • Spine fold press sensor (R) connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine fold HP sensor (R).

  • Replace the spine fold press sensor (R).

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-63

D

Perfect Binder: Spine fold plate open position late error

At the start of the spine fold operation, the spine plate open sensor did not go ON, even after the spine plate motor operated for 900 ms (93.75 mm of feed).

  • Spine plate motor connector loose, broken, defective

  • Motor defective

  • Spine open sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine plate motor.

  • Replace the spine open sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-64

D

Perfect Binder: Spine fold plate open position lag error

At the start of the spine fold operation, the spine plate open sensor did not go OFF, even after the spine plate motor operated for 1350 ms (93.75 mm of feed).

  • Spine plate motor connector loose, broken, defective

  • Motor defective

  • Spine open sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine plate motor.

  • Replace the spine open sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-65

D

Perfect Binder: Spine fold plate close position late error

At the start of the spine fold operation, the spine plate close sensor did not go ON, even after the spine plate motor operated for 2250 ms (93.75 mm of feed).

  • Spine plate motor connector loose, broken, defective

  • Motor defective

  • Spine close sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine plate motor.

  • Replace the spine close sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-66

D

Perfect Binder: Spine fold plate close position lag error

At the start of the spine fold operation, the spine plate close sensor did not go OFF, even after the spine plate motor operated for 505 ms.

  • Spine plate motor connector loose, broken, defective

  • Motor defective

  • Spine close sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the spine plate motor.

  • Replace the spine close sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-67

D

Perfect Binder: Front door lock error

The front door lock release sensor did not go off, even though the door was locked.

  • Front door lock solenoid defective

  • Front door lock release sensor defective

  • Reconnect the connector.

  • Replace the front door lock solenoid.

  • Replace the front door lock release sensor.

  • Replace the master control board.

  • Replace the SOL harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-68

D

Perfect Binder: Front door lock release error

The front door lock release sensor did not go ON, even though the door was unlocked.

  • Front door lock solenoid defective

  • Front door lock release sensor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the front door lock solenoid.

  • Replace the front door lock release sensor.

  • Replace the master control board.

  • Replace the SOL harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-69

D

Perfect Binder: Front door force open error

The front door was detected open, even though it was locked.

  • Front door switch defective

  • Front door solenoid defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the front door lock solenoid.

  • Replace the front door switch.

  • Replace the master control board.

  • Replace the SOL harness.

  • Replace the SW harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-70

D

Perfect Binder: Switchback flapper HP sensor late error

During the switchback flapper lift operation, the switchback flapper HP sensor did not go ON, even though the switchback flapper motor operated long enough for lifting through an arc of 50 degrees.

  • Switchback flapper HP sensor defective

  • Switchback flapper motor defective

  • Replace the switchback flapper motor.

  • Replace the switchback flapper HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Reconnect the connector.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-71

D

Perfect Binder: Switchback flapper HP sensor lag error

During the switchback flapper lift operation, the switchback flapper HP sensor did not go OFF, even though the switchback flapper motor operated long enough for lowering through an arc of 150 degrees.

  • Switchback flapper HP sensor defective

  • Switchback flapper motor defective

  • Connector loose, broken, defective

  • Replace the switchback flapper motor.

  • Replace the switchback flapper HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Reconnect the connector.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-72

D

Perfect Binder: TE press lever HP sensor late error

When the trailing edge press lever was released, the TE press lever HP sensor did not go ON, even though the TE press lever motor operated long enough to move the lever through and arc of 30 degrees.

  • TE press lever sensor defective

  • TE press lever motor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the TE press lever motor.

  • Replace the TE press lever HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-73

D

Perfect Binder: TE press lever HP sensor lag error

When the trailing edge press lever was released, the TE press lever HP sensor did not go OFF, even though the TE press lever motor operated long enough to move the lever through and arc of 20 degrees.

  • TE press lever sensor defective

  • TE press lever motor defective

  • Reconnect the connector.

  • Replace the TE press lever motor.

  • Replace the TE press lever HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-74

D

Perfect Binder: Jog fence front HP sensor late error

The front jog fence HP sensor did not go ON, even thought the jog fence motor operated long enough for 60 mm of feed.

  • Jog fence front HP sensor defective

  • Jog fence front motor defective

  • Reconnect the connector.

  • Replace the jog fence front motor.

  • Replace the jog fence front HP sensor

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-75

D

Perfect Binder: Jog fence front HP sensor lag jam

While small-size paper was being jogged, the jog fence front HP sensor did not go OFF after the front jog fence motor operated long enough for 40 mm of feed.

  • Jog fence front HP sensor defective

  • Jog fence front motor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the jog fence front motor.

  • Replace the jog fence front HP sensor

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-76

D

Perfect Binder: Jog fence large HP sensor late error

While large-size paper was being jogged, the front jog fence large HP sensor did not go ON, even though the jog fence front motor operated long enough for 70mm of feed.

  • Jog fence front large HP sensor defective

  • Front jog fence motor defective

  • Reconnect the connector.

  • Replace the jog fence front motor.

  • Replace the Jog fence front large HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-77

D

Perfect Binder: Jog fence front large HP sensor lag error

While large-size paper was being jogged, the jog fence front large HP sensor did not go OFF after the front jog fence motor operated long enough for 20 mm of feed.

  • Jog fence front large HP sensor defective

  • Jog fence front motor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the jog fence front motor.

  • Replace the Jog fence front large HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-78

D

Perfect Binder: Jog fence front HP sensor late error

While jogging small-size paper, the right jog fence HP sensor did not go ON, even though the jog fence motor operated long enough for 60 mm of feed.

  • Jog fence right HP sensor defective

  • Jog fence right motor defective

  • Reconnect the connector.

  • Replace the jog fence right motor.

  • Replace the jog fence right HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-79

D

Perfect Binder: Jog fence right HP sensor lag jam

While small-size paper was being jogged, the jog fence right HP sensor did not go OFF after the right jog fence motor operated long enough for 40 mm of feed.

  • Jog fence right HP sensor defective

  • Jog fence right motor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the jog fence right motor.

  • Replace the jog fence right HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-80

D

Perfect Binder: Jog fence right large HP sensor late error

While large-size paper was being jogged, the right jog fence large HP sensor did not go ON, even though the jog fence front motor operated long enough for 70mm of feed.

  • Jog fence right large HP sensor defective

  • Jog fence right motor defective

  • Reconnect the connector.

  • Replace the jog fence right motor.

  • Replace the jog fence right large HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-81

D

Perfect Binder: Jog fence right large HP sensor lag error

While large-size paper was being jogged, the jog fence right large HP sensor did not go OFF after the right jog fence motor operated long enough for 20 mm of feed.

  • Jog fence right large HP sensor defective

  • Jog fence right motor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the jog fence right motor.

  • Replace the jog fence right large HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-82

D

Perfect Binder: Switchback roller HP sensor late error

During the switchback roller lift operation, the switchback roller HP sensor did not go ON, even though the switchback roller lift motor operated long enough for lifting through an arc of 40 degrees.

  • Switchback roller HP sensor defective

  • Switchback lift motor defective

  • Reconnect the connector.

  • Replace the switchback lift motor.

  • Replace the switchback roller HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-83

D

Perfect Binder: Switchback roller HP sensor lag error

During the switchback roller lowering, the switchback roller HP sensor did not go OFF, even though the switchback roller lift motor operated long enough for lowering through an arc of 40 degrees.

  • Switchback roller HP sensor defective

  • Switchback roller lift motor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the switchback lift motor.

  • Replace the switchback roller HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-84

D

Perfect Binder: Stacking tray lower limit late error

When the stacking tray was lowered, the tray lower limit sensor did not go ON after the stacking tray lift motor had operated long enough for 90 mm of lift.

  • Tray lower limit sensor defective

  • Stacking tray lift motor defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the tray lower limit sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-85

D

Perfect Binder: Stacking tray low limit lag error

When the stacking tray was raised, the tray lower limit sensor did not go OFF after the stacking tray lift motor had operated long enough for 30mm of lift.

  • Tray lower limit sensor defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the tray lower limit sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-86

D

Perfect Binder: Paper detect sensor (front) detection error



When the stacking tray was raised, the paper detect sensor (front) did not go ON, even after the stacking tray overflow sensor went ON and the stacking tray lift motor had operated for 30 mm of lift.

  • Paper detect sensor (front) defective

  • Stacking tray lift motor defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the paper detect sensor (front).

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-87

D

Perfect Binder: Paper detect sensor (front) no paper detection error

When the stacking tray was lowered, the tray lower limit sensor did not go OFF after the stacking tray lift motor had operated long enough for 10mm of lowering.

  • Paper detect sensor (front) defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the paper detect sensor (front).

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-88

D

Perfect Binder: Paper detect sensor (rear) paper detection error

When the stacking tray was raised, the paper detect sensor (rear) did not go ON, even after the stacking tray overflow sensor went ON and the stacking tray lift motor had operated for 40 mm of lift.

  • Paper detect sensor (rear) defective

  • Stacking tray lift motor defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the paper detect sensor (rear).

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC751-89

D

Perfect Binder: Paper detect sensor (rear) no paper detection error

When the stacking tray was lowered, the paper detect sensor (rear) did not go OFF after the stacking tray lift motor had operated long enough for 10mm of lowering.

  • Paper detect sensor (rear) defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the paper detect sensor (rear).

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-10

D

Perfect Binder: Stack overflow sensor detection late error

When the stacking tray was raised, the stack overflow sensor did not go OFF after the stacking tray lift motor had operated long enough for 70mm lowering.

  • Stack overflow sensor defective

  • Stacking tray lift motor defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the stack overflow sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-11

D

Perfect Binder: Stacking tray low limit sensor error 1

The stacking tray low limit sensor and the stack overflow sensor went ON at the same time.

  • Tray lower limit sensor defective

  • Stack overflow sensor defective

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the stack overflow sensor.

  • Replace the master control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-12

D

Perfect Binder: Stack overflow sensor detection position late error

When the tray was lowered to allow removal of the booklets, the stack overflow sensor did not go OFF, even after the stacking tray lift motor had operated long enough for 40mm of lift.

  • Stack overflow sensor defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the stack overflow sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-13

D

Perfect Binder: Stacking tray low limit sensor error 2

When the stacking tray was lifted, the stack overflow sensor did not go OFF, even though the either (or both) the paper detect sensor (front) or the paper detect sensor (rear) were on while the stacking tray empty sensor was OFF.

  • Tray empty sensor defective

  • Paper detect sensors (front, rear, or both) defective

  • Stack overflow sensor defective

  • Tray lift motor defective

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the tray empty sensor.

  • Replace the paper detect sensors (front).

  • Replace the paper detect sensors (rear).

  • Replace the stack overflow sensor.

  • Replace the master control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-14

D

Perfect Binder: Stack tray HP sensor late error

When the tray moved to the home position, the HP sensor did not go ON after enough time for 70mm of movement had elapsed.

  • Stack tray HP sensor defective

  • Stacking tray lift motor defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the stack tray HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-15

D

Perfect Binder: Stack tray HP sensor lag error

When the tray moved from the home position, the HP sensor did not go OFF after enough time for 10mm of movement had elapsed.

  • Stack tray HP sensor defective

  • Stacking tray motor defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the stack tray HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-16

D

Perfect Binder: Stack weight move HP sensor late error

When the tray moved to the home position, the stack weight move HP sensor did not go ON after enough time for 70mm of movement had elapsed.

  • Stack weight HP sensor defective

  • Stack weight motor defective

  • Reconnect the connector.

  • Replace the stack weight motor.

  • Replace the stack weight HP sensor defective.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-17

D

Perfect Binder: Stack weight HP sensor lag error

During movement away from the HP sensor, the HP sensor did not go OFF after enough time for 10mm of movement had elapsed.

  • Stack weight HP sensor defective

  • Stack weight motor defective

  • Reconnect the connector.

  • Replace the stack weight motor.

  • Replace the stack weight HP sensor defective.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-18

D

Perfect Binder: Cover guide HP sensor (left) late error

During movement toward the HP sensor of the left cover path, the cover guide HP sensor (left) did not go ON after the cover guide motor (left) had operated long enough for 3000 ms of movement.

  • Cover guide (left) HP sensor defective

  • Cover guide motor (left) defective

  • Reconnect the connector.

  • Replace the cover guide motor (left).

  • Replace the cover guide (left) HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-19

D

Perfect Binder: Cover guide (left) HP sensor error

The cover guide HP sensor (left) and cover guide (left) open sensor went ON at the same time.

  • Cover guide HP sensor (L) defective

  • Cover guide open sensor (left)

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the cover guide HP sensor (L).

  • Replace the cover guide open sensor (left).

  • Replace the master control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-20

D

Perfect Binder: Left cover guide release position late error

During movement toward the left cover guide open position, the cover guide open sensor (left) did not go ON after the cover guide motor (left) had operated long enough for 3000 ms of movement.

  • Cover guide (left) open sensor defective

  • Cover guide motor (left) defective

  • Reconnect the connector.

  • Replace the cover guide motor (left).

  • Replace the Cover guide (left) open sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-21

D

Perfect Binder: Cover guide (right) HP sensor late error

During movement toward the HP sensor of the right cover path, the cover guide HP sensor (right) did not go ON after the cover guide motor (right) had operated long enough for 3000 ms of movement.

  • Cover guide (right) HP sensor defective

  • Cover guide motor (right) defective

  • Reconnect the connector.

  • Replace the cover guide motor (right).

  • Replace the cover guide (right) HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-22

D

Perfect Binder: Cover guide (right) sensor error

The cover guide HP sensor (right) and cover guide (right) open sensor went ON at the same time.

  • Cover guide HP sensor (R) defective

  • Cover guide open sensor (right)

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the cover guide (right) HP sensor.

  • Replace the cover guide open sensor (right).

  • Replace the master control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-23

D

Perfect Binder: Right cover guide release position late error

During movement toward the right cover guide open position, the cover guide open sensor (right) did not go ON after the cover guide motor (right) had operated long enough for 3000 ms of movement.

  • Cover guide (right) HP sensor defective

  • Cover guide motor (right) defective

  • Reconnect the connector.

  • Replace the cover guide motor (right).

  • Replace the cover guide open sensor (right).

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-24

D

Perfect Binder: Registration unit HP late error

When the cover registration unit moved toward the home position, the cover horizontal registration sensor did not go ON, even after the cover horizontal registration motor had operated for 975 ms.

  • Cover horizontal registration motor defective

  • Cover registration HP sensor defective

  • Reconnect the connector.

  • Replace the cover horizontal registration motor.

  • Replace the cover registration HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-25

D

Perfect Binder: Registration HP sensor lag error

During operation of the cover registration unit , the cover horizontal registration HP sensor did not go OFF, even after the cover horizontal registration motor had operated for 975 ms.

  • Cover horizontal registration motor defective

  • Registration HP sensor defective

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the cover horizontal registration motor.

  • Replace the registration HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-26

D

Perfect Binder: Sub grip HP sensor late error

During the sub grip lift operation, the sub grip upper HP sensor did not go ON, even though the sub grip lift motor had operated for 4110 ms.

  • Sub grip lift motor defective

  • Sub grip upper HP sensor defective

  • Reconnect the connector.

  • Replace the sub grip lift motor.

  • Replace the sub grip upper HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-27

D

Perfect Binder: Sub grip HP sensor lag error

During sub grip lowering, the sub grip lower HP sensor did not go OFF, even though the sub grip lift motor had operated for 240 ms.

  • Sub grip lift motor defective

  • Sub grip lower HP sensor defective

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the sub grip lift motor.

  • Replace the sub grip upper HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-28

D

Perfect Binder: Sub grip size HP sensor late error

  • When the sub grip unit opened horizontally, the size move HP sensor did not go ON, even after the size move motor had operated for 726 ms, or operated long enough for 108.75 mm of movement.

  • After the sub grip unit moved to the horizontal release position, the sub grip size HP sensor was already OFF.

  • Sub grip size motor defective

  • Sub grip size HP sensor defective

  • Reconnect the connector.

  • Replace the sub grip size motor.

  • Replace the sub grip size HP sensor defective.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-29

D

Perfect Binder: Sub grip size HP sensor lag error

  • When the sub grip unit closed horizontally, the size move HP sensor did not go OFF, even after the size move motor had operated for 500 ms, or operated long enough for 108.75 mm of movement.

  • After the sub grip unit moved from the horizontal close position to the open position, the size shift HP sensor was already ON.

  • Sub grip size motor defective

  • Sub grip size HP sensor defective

  • Harness connector, loose, broken, defective

  • Reconnect the connector.

  • Replace the sub grip size motor.

  • Replace the sub grip size HP sensor defective.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-30

D

Perfect Binder: Sub grip open position late error

At the start of the sub grip open operation, the SG open sensor did not go ON, even after the SG motor had operated for 1500 ms.

  • SG motor drive board defective

  • SG open sensor defective

  • Replace the SG motor.

  • Replace the SG open sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Reconnect the connector.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-31

D

Perfect Binder: Sub grip open position lag error

At the start of the sub grip close operation, the SG open sensor did not go OFFN, even after the SG motor had operated for 500 ms.

  • SG motor defective

  • SG open sensor defective

  • Harness connector loose, broken, defective

  • Replace the SG motor.

  • Replace the SG open sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Reconnect the connector.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-32

D

Perfect Binder: Sub grip close position late error

At the start of the sub grip close operation, the SG close sensor did not go ON, even after the SG motor had operated for 1500 ms.

  • SG motor defective

  • SG close sensor defective

  • Reconnect the connector.

  • Replace the SG motor.

  • Replace the SG close sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-33

D

Perfect Binder: Sub grip close position lag error

At the start of the sub grip open operation, the SG close sensor did not go OFF, even after the SG motor had operated for 500 ms.

  • SG motor defective

  • SG close sensor defective

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the SG motor.

  • Replace the SG close sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-34

D

Perfect Binder: Sub grip sensor error

The SG open sensor and SG close sensor went ON at the same time.

  • SG open sensor defective

  • SG close sensor defective

  • Harness connector loose, broken, defective

  • Reconnect the connector.

  • Replace the SG open sensor.

  • Replace the SG close sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-35

D

Perfect Binder: Sub grip HP late error

While moving to the sub grip home position, the sub grip HP sensor did not go ON, even though the sub grip motor had operated for 3000 ms.

  • Sub grip motor defective

  • Sub grip HP sensor defective

  • Reconnect the connector.

  • Replace the signature movement motor.

  • Replace the signature movement HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-36

D

Perfect Binder: Sub grip HP position lag error

While passing the signature, the sub grip HP sensor did not go OFF, even though the sub grip motor had operated for 500 ms.

  • Sub grip motor defective

  • Sub grip HP sensor defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the signature movement motor.

  • Replace the signature movement HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-37

D

Perfect Binder: Signature move main grip position late error

While sub grip was passing the signature, the signature move MG position sensor did not go ON, even though the signature move motor had operated for 3000 ms. At the timing of the movement of the signature from sub grip to main grip, the signature was still gripped by the main grip at the rotation HP sensor.

  • Signature movement motor defective

  • Signature MG position sensor defective

  • Reconnect the connector.

  • Replace the signature movement motor.

  • Replace the signature MG position sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-38

D

Perfect Binder: Signature move main grip position lag error

While moving to the sub grip home position, the signature MG position sensor did not go OFF, even though the signature move motor had operated for 500 ms.

  • Signature move motor defective

  • Signature MG position HP sensor defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the signature move motor.

  • Replace the signature MG position HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-39

D

Perfect Binder: Main grip rotate enable position sensor late error

While moving to the sub grip home position, the MG rotate enable sensor did not go ON, even though the signature move motor had operated for 2475 ms.

  • Signature move motor defective

  • MG rotate enable sensor defective

  • Reconnect the connector.

  • Replace the signature move motor.

  • Replace the MG rotate enable sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-40

D

Perfect Binder: Main grip rotate enable position sensor lag error

While passing the signature, the MG rotate enable sensor did not go OFF, even though the signature move motor had operated for 1450 ms.

  • Signature move motor defective

  • MG rotate enable sensor defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the signature move motor.

  • Replace the MG rotate enable sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-41

D

Perfect Binder: Signature move HP sensor defective

The signature move HP sensor and signature move MG position sensor went on at the same time.

  • Signature move HP sensor defective

  • Signature MG position HP sensor defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the signature move HP sensor.

  • Replace the signature MG position HP sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-42

D

Perfect Binder: Main grip HP sensor late error

  • During main grip lift, the MG HP sensor did not go ON, even though the main grip lift motor had operated for 6185 ms.

  • MG HP sensor did not go OFF when the main grip moved from up position to down position.

  • MG lift motor defective

  • MG HP sensor defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-43

D

Perfect Binder: Main grip HP sensor lag error

  • During main grip lowering, the MG HP sensor did not go OFF, even though the main grip lift motor had operated for 1455 ms.

  • MG HP sensor did not go ON when the main grip moved from down position to up position.

  • MG lift motor defective

  • MG HP sensor defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-44

D

Perfect Binder: Main grip press sensors(S) position late error

When lifting from main grip signature registration position, MG press sensor did not go ON, even though the MG lift motor had operated for 95 ms.

  • MG lift motor defective

  • MG press sensor defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG press sensor(S).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-45

D

Perfect Binder: Main grip press sensor (S) position lag error

When lowering to main grip signature registration position, MG press sensor (S) did not go OFF, even though the MG lift motor had operated for 5640 ms.

  • MG lift motor defective

  • MG press sensor (S) defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG press sensor (S).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-46

D

Perfect Binder: Main grip press sensor (L) position late error

When lowering cover in main grip to press position, MG press sensor (L) did not go ON, even though the MG lift motor had operated for 6185 ms.

  • MG lift motor defective

  • MG press sensor (L) defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG press sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-47

D

Perfect Binder: Main grip press sensor (L) position lag error

When raising cover in main grip from press position, MG press sensor (L) did not go OFF, even though the MG lift motor had operated for 95 ms.

  • MG lift motor defective

  • MG press sensor (L) defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG press sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-48

D

Perfect Binder: Signature exit sensor late error

When signature was passed from main grip to signature exit roller, signature exit sensor did not go ON after MG lift motor moved to signature turnover position.

  • MG lift motor defective

  • Signature exit sensor defective

  • Signature out of position, snagged on main grip

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the signature exit sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-49

D

Perfect Binder: Main grip HP sensor (L) late error

During main grip lift, the MG HP sensor (L) did not go ON, even though the main grip lift motor had operated for 6185 ms.

  • MG lift motor defective

  • MG HP sensor (L) defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG HP sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-50

D

Perfect Binder: Main grip HP sensor (L) lag error

During main grip lowering, the MG HP sensor (L) did not go OFF, even though the main grip lift motor had operated for 1455 ms.

  • MG lift motor defective

  • MG HP sensor (L) defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG HP sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-51

D

Perfect Binder: Main grip rotate HP sensor late error

  • When rotating signature to main grip turnover position, MG rotate HP sensor did not go ON, even though the MG rotate motor had operated for 2250 ms.

  • There is paper present at some location other than the sub grip HP sensor, and no paper at the MG rotate HP sensor of the main grip.

  • MG rotate motor defective

  • MG rotate HP sensor defective

  • Reconnect the connector.

  • Replace the MG rotate motor.

  • Replace the MG rotate HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-52

D

Perfect Binder: Main grip rotate HP sensor lag error

When rotating signature to main grip binding position, the MG rotate HP sensor did not go OFF, even though the MG rotate motor had operated for 500 ms.

  • MG rotate motor defective

  • MG rotate HP sensor defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG rotate motor.

  • Replace the MG rotate HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-53

D

Main grip rotate-to-binding position late error

When rotating signature to main grip binding position, the MG rotate-to-binding position sensor did not go ON, even though the MG rotate motor had operated for 2250 ms.

  • MG rotate motor defective

  • MG rotate-to-binding position sensor defective

  • Reconnect the connector.

  • Replace the MG rotate motor.

  • Replace the MG rotate-to-binding position sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-54

D

Main grip rotate-to-binding position lag error

When rotating signature to main grip turnover position, MG rotate-to-binding position sensor did not go OFF, even though the MG rotate motor had operated for 500 ms.

  • MG rotate motor defective

  • MG rotate-to-binding position sensor defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG rotate motor.

  • Replace the MG rotate-to-binding position sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-55

D

Perfect Binder: Main grip rotate sensor error

The MG rotate HP sensor and MG rotate-to-binding position sensor went on at the same time.

  • MG rotate HP sensor defective

  • MG rotate-to-binding position sensor defective

  • Connector harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG rotate-to-binding position sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-56

D

Perfect Binder: Main grip open sensor (R) late error

At the start of the main grip open operation, the MG open sensor (R) did not go ON, even after the MG motor (R) had operated for 3000 ms.

  • Main grip motor (R) defective

  • MG open sensor (R) defective

  • Reconnect the connector.

  • Replace the main grip motor (R).

  • Replace the MG open sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-57

D

Perfect Binder: Main grip open sensor (R) lag error

At the start of the main grip close operation, the MG open sensor (R) did not go OFF, even after the MG motor (R) had operated for 500 ms.

  • Main grip motor (R) defective

  • Main grip open sensor (R) defective

  • Connector or harness loose, broken, defective

  • Reconnect the connector.

  • Replace the main grip motor (R).

  • Replace the MG open sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-58

D

Perfect Binder: Main grip close sensor (R) late error

At the start of the main grip close operation, the MG close sensor (R) did not go ON, even after the MG motor (R) had operated for 3000 ms.

  • Main grip motor (R) defective

  • MG close sensor (R) defective

  • Reconnect the connector.

  • Replace the main grip motor (R).

  • Replace the MG close sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-59

D

Perfect Binder: Main grip close sensor (R) lag error

At the start of the main grip close operation, the MG close sensor (R) did not go OFF, even after the MG motor (R) had operated for 500 ms.

  • Main grip motor (R) defective

  • Main grip close sensor (R) defective

  • Connector or harness loose, broken, defective

  • Reconnect the connector.

  • Replace the main grip motor (R).

  • Replace the MG close sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-60

D

Perfect Binder: Main grip motor (R) rotation error

At the start of the main grip open operation, the MG encoder sensor (R) was not detected on/off, even after the MG motor (R) had operated for 200 ms.

  • Main grip motor (R) defective

  • Main grip encoder sensor (R) defective

  • Connector or harness loose, broken, defective

  • Reconnect the connector.

  • Replace the main grip motor (R).

  • Replace the main grip encoder sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-61

D

Perfect Binder: Main grip (R) sensor error

The MG open sensor (R) and MG close sensor (R) went ON at the same time.

  • Main open sensor (R) defective

  • Main grip close sensor (R) defective

  • Connector or harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG open sensor (R).

  • Replace the main grip encoder sensor (R).

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-62

D

Perfect Binder: Main grip open sensor (F) late error

At the start of the main grip open operation, the MG open sensor (F) did not go ON, even after the MG motor (R) had operated for 3000 ms.

  • Main grip motor (F) defective

  • MG open sensor (F) defective

  • Reconnect the connector.

  • Replace the main grip motor (F).

  • Replace the MG open sensor (F).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-63

D

Perfect Binder: Main grip open sensor (F) lag error

At the start of the main grip close operation, the MG open sensor (F) did not go OFF, even after the MG motor (F) had operated for 500 ms.

  • MG motor (F) defective

  • MG open sensor (F) defective

  • Connector or harness loose, broken, defective

  • Reconnect the connector.

  • Replace the main grip motor (F).

  • Replace the MG open sensor (F).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-64

D

Perfect Binder: Main grip close sensor (F) late error

At the start of the main grip open operation, the MG close sensor (F) did not go ON, even after the MG motor (F) had operated for 3000 ms.

  • MG motor (F) defective

  • MG close sensor (F) defective

  • Reconnect the connector.

  • Replace the MG motor (F).

  • Replace the MG close sensor (F).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-65

D

Perfect Binder: Main grip close sensor (F) lag error

At the start of the main grip open operation, the MG close sensor (F) did not go OFF, even after the MG motor (F) had operated for 500 ms.

  • MG motor (F) defective

  • MG close sensor (F) defective

  • Connector or harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG motor (F).

  • Replace the MG close sensor (F).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-66

D

Perfect Binder: Main grip motor (F) rotation error

At the start of the main grip open/close operation, the MG encoder sensor (F) was not detected on/off, even after the MG motor (F) had operated for 200 ms.

  • MG motor (F) defective

  • MG encoder sensor (F) defective

  • Connector or harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG motor (F).

  • Replace the MG encoder sensor (F).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-67

D

Perfect Binder: Main grip (F) sensor error

The MG open sensor (F) and MG close sensor (F) went ON at the same time.

  • MG open sensor (F) defective

  • MG close sensor (F) defective

  • Connector or harness loose, broken, defective

  • Reconnect the connector.

  • Replace the MG open sensor (F).

  • Replace the MG encoder sensor (F).

  • Replace the slave control board.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-68

D

Perfect Binder: Signature exit path HP sensor late error

During signature output roller separation, the signature exit path sensor did not go ON, even after the signature exit path motor was ON for 750 ms.

  • Signature path exit motor defective

  • Signature path exit HP sensor defective

  • Reconnect the connector.

  • Replace the signature path exit motor.

  • Replace the signature path exit HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-69

D

Perfect Binder: Signature exit path HP sensor lag error

During signature exit roller nip operation, the signature exit path sensor did not go OFF, even after the signature exit path motor was OFF for 300 ms.

  • Signature path exit motor defective

  • Signature path exit HP sensor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the signature path exit motor.

  • Replace the signature path exit HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-70

D

Perfect Binder: Signature path exit press sensor late error

During signature exit roller nip operation, the signature exit path exit press sensor did not go ON, even after the signature exit path motor operated for 300 ms.

  • Signature path exit motor defective

  • Signature path exit press sensor defective

  • Reconnect the connector.

  • Replace the signature path exit motor.

  • Replace the signature path exit press sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-71

D

Perfect Binder: Signature path exit press sensor lag error

During signature output roller separation, the signature exit path press sensor did not go OFF, even after the signature exit path motor was ON for 300 ms.

  • Signature path exit motor defective

  • Signature path exit press sensor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the signature path exit motor.

  • Replace the signature path exit press sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-72

D

Perfect Binder: Leading edge sensor late error

When signature exited at signature path exit roller, the leading edge sensor did not go ON, even after the signature exit roller motor operated long enough to feed the book 45 mm.

  • Signature exit roller motor defective

  • Leading edge sensor defection

  • Signature jam

  • Reconnect the connector.

  • Replace the signature exit roller motor.

  • Replace the leading edge sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-73

D

Perfect Binder: Cover interposer tray read error

At power on the data on the EEPROM returned a checksum error when the data were read.

  • EEPROM defective

  • Replace the EEPROM on the inserter control board.

  • Replace the inserter control board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-74

D

Perfect Binder: Cover interposer tray EEPROM write error

When data were written to EEPROM, the write data and read data did not match.

  • EEPROM defective

  • EEPROM not installed, not installed correctly

  • Replace the EEPROM on the inserter control board.

  • Replace the inserter control board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-75

D

Perfect Binder: Drive switch motor error (down to up)

The rack where the drive gear is mounted did not retract from the drive switch sensor after the drive switch motor operated for 3 s.

  • Drive switch motor defective

  • Drive switch sensor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the drive switch motor.

  • Replace the drive switch sensor.

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-76

D

Perfect Binder: Drive switch motor error (up to down) error

The rack where the drive gear is mounted was late arriving at the drive switch sensor after the drive switch motor operated for 3 s.

  • Drive switch motor defective

  • Drive switch sensor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the drive switch motor.

  • Replace the drive switch sensor.

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-77

D

Perfect Binder: Upper tray low position late error

The upper tray did not leave the lower limit sensor after the upper tray lift motor had operated for 5 s.

  • Upper tray lift motor defective

  • Upper tray low limit sensor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the upper tray lift motor.

  • Replace the upper tray low limit sensor.

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-78

D

Perfect Binder: Upper tray feed position late error

The upper tray did not arrive at the PICK sensor after the upper tray lift motor had operated for 5 s.

  • Upper tray lift motor defective

  • Upper tray PICK sensor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the upper tray lift motor.

  • Replace the upper tray PICK sensor.

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-79

D

Perfect Binder: Lower tray low position lag error

The lower tray did not leave the low limit sensor after the lower tray lift motor had operated for 5 s.

  • Lower tray lift motor defective

  • Lower tray low limit sensor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the lower tray lift motor.

  • Replace the lower tray low limit sensor.

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-80

D

Perfect Binder: Lower tray paper feed position late error

The lower tray did not leave the lower tray paper feed sensor after the lower tray lift motor had operated for 5 s.

  • Lower tray lift motor defective

  • Lower tray PICK sensor defective

  • Connector loose, broken, defective

  • Reconnect the connector.

  • Replace the lower tray lift motor.

  • Replace the lower tray PICK sensor.

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-81

D

Perfect Binder: Low performance error (or service mode)

  • When error occurred, wrinkling possible where there was no affect from straight-through feed.

  • If jam occurred at straight-through feed, the paper may not have fed.

  • The error may have occurred at straight-through feed. One or more of these conditions exit.

  • Check for paper jams and then remove

  • After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-82

B

Perfect Binder: Grip HP sensor lag error

During operation of the grip unit the HP sensor did not OFF after grip unit moved 20 mm.

  • Grip motor overloaded, defective

  • Grip HP sensor defective

  • Sensor flag defective

  • Connector loose, broken defective

  • Reconnect the connector.

  • Replace the grip motor.

  • Replace the grip HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-83

B

Perfect Binder: Grip HP sensor late error

The HP sensor did not go ON after the grip unit released the signature and moved 76 mm.

  • Grip motor overloaded, defective

  • Grip HP sensor defective

  • Sensor flag defective

  • Connector loose, broken defective

  • Reconnect the connector.

  • Replace the grip motor.

  • Replace the grip HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-84

B

Perfect Binder: Grip end sensor lag error

  • The grip end sensor did not go off after the grip unit released the signature and moved the prescribed distance.

  • The grip end sensor did not go off, even after the booklet had been released after moving 86 mm.

  • Grip motor overloaded, defective

  • Grip end sensor defective

  • Sensor flag defective

  • Connector loose, broken defective

  • Reconnect the connector.

  • Replace the grip motor.

  • Replace the grip end sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-85

B

Perfect Binder: Grip end sensor late error

  • The grip end sensor did not go on, even after the booklet had been had been moved 86 mm.

  • The grip end sensor did not go on within 3.7 sec. after the book was gripped.

  • Grip motor overloaded, defective

  • Grip end sensor defective

  • Sensor flag defective

  • Connector loose, broken defective

  • No data incoming from signature thickness sensor

  • Reconnect the connector.

  • Replace the grip motor.

  • Replace the grip end sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-86

B

Perfect Binder: Left trimming buffer HP sensor lag error

The left trimmings buffer HP sensor did not go OFF within 3 sec. after the trimmings buffer moved away from the sensor.

  • Trimmings buffer motor defective

  • Motor connector loose, broken, defective

  • Left trimmings buffer HP sensor defective

  • Buffer full of trimmings

  • Reconnect the connector.

  • Replace the trimmings buffer motor.

  • Replace the left trimmings buffer HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-87

B

Perfect Binder: Trimming buffer HP sensor late error

The left trimmings buffer HP sensor did not go ON within 5 sec. after the trimmings buffer moved toward the sensor.

  • Buffer full of trimmings

  • Trimmings buffer motor defective

  • Motor connector loose, broken, defective

  • Left trimmings buffer HP sensor defective

  • Reconnect the connector.

  • Replace the trimmings buffer motor.

  • Replace the left trimmings buffer HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-88

B

Perfect Binder: Right trimming buffer HP sensor lag error

The right trimmings buffer HP sensor did not go OFF within 3 sec. after the trimmings buffer moved away from the sensor.

  • Buffer full of trimmings

  • Trimmings buffer motor defective

  • Motor connector loose, broken, defective

  • Right trimmings buffer HP sensor defective

  • Reconnect the connector.

  • Replace the trimmings buffer motor.

  • Replace the right trimmings buffer HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC752-89

B

Perfect Binder: Right trimming buffer HP sensor late error

The right trimmings buffer HP sensor did not go ON within 5 sec. after the trimmings buffer moved toward the sensor.

  • Buffer full of trimmings

  • Trimmings buffer motor defective

  • Motor connector loose, broken, defective

  • Right trimmings buffer HP sensor defective

  • Reconnect the connector.

  • Replace the trimmings buffer motor.

  • Replace the right trimmings buffer HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-10

B

Perfect Binder: Trimmings buffer motor rotation error

No encoder lock input received within 50 ms during operation.

  • Trimmings buffer motor defective

  • Motor connector loose, broken, defective

  • Left trimmings buffer end sensor defective

  • Buffer full of trimmings

  • Reconnect the connector.

  • Replace the trimmings buffer motor.

  • Replace the trimming buffer encoder sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-11

B

Perfect Binder: Thrust plate operation error

The thrust press plate sensor did not go OFF after the trimmings buffer moved to the left for 3 sec. (blocked by jammed trimming scraps).

  • Trimmings buffer motor defective

  • Motor connector loose, broken, defective

  • Thrust plate sensor defective

  • Buffer full of trimmings

  • Reconnect the connector.

  • Replace the trimmings buffer motor.

  • Replace the thrust plate sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-12

B

Perfect Binder: Thrust plate retraction error

The paper press plate sensor did not go ON after the trimmings buffer moved to the right for 3 sec. (blocked by jammed trimming scraps).

  • Trimmings buffer motor defective

  • Motor connector loose, broken, defective

  • Thrust plate sensor defective

  • Buffer full of trimmings

  • Reconnect the connector.

  • Replace the trimmings buffer motor.

  • Replace the thrust plate sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-13

B

Perfect Binder: Book collection buffer HP sensor error

The book collection buffer HP sensor did not go OFF within the time prescribed for release of the book in the book buffer.

  • Book buffer tray motor connector loose, broken, defective

  • Motor overload, defective

  • Book collection buffer tray HP sensor loose, broken, defective

  • Mechanism blocked by paper scraps

  • Reconnect the connector.

  • Replace the book buffer tray motor.

  • Replace the book collection buffer tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-14

B

Perfect Binder: Book collection buffer tray HP sensor late error

The book collection buffer HP sensor did not go off even after the book buffer tray moved for 3 sec.

  • Book buffer tray motor connector loose, broken, defective

  • Motor overload

  • Motor defective

  • Book collection buffer tray HP sensor loose, broken, defective, Blocked by paper scraps

  • Reconnect the connector.

  • Replace the book buffer tray motor.

  • Replace the book collection buffer tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-15

B

Perfect Binder: Press HP sensor lag error

During press plate operation during trimming, the edge press plate HP sensor did not OFF after it had time to move the prescribed distance.

  • Edge press plate motor connection loose, broken, defective

  • Motor overloaded, defective

  • Edge press plate HP sensor connection loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the edge press plate motor.

  • Replace the edge press plate HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-16

B

Perfect Binder: Press plate late error

  • Edge press plate sensor did not go ON within 15 sec. of edge press release.

  • The edge press plate motor stopped when the edge press plate HP sensor switched ON, but after it stopped the HP sensor went OFF.

  • Edge press plate motor connection loose, broken, defective

  • Motor overloaded

  • Motor defective

  • Edge press plate HP sensor connection loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the edge press plate motor.

  • Replace the edge press plate HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-17

B

Perfect Binder: Press end sensor lag jam

After the press plate released the signature and moved the prescribed distance, the press end sensor did not go OFF.

  • Edge press plate motor connector loose, broken, defective

  • Motor overloaded, defective

  • Press end sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the edge press plate motor.

  • Replace the press end sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-18

B

Perfect Binder: Press end sensor late jam

  • The press end sensor did not go ON within 8 sec. after the press operation started

  • Operation stopped when the press end sensor went ON, but sensor went off after the operation stopped.

  • Edge press plate motor connector loose, broken, defective

  • Motor overloaded, defective

  • Press end sensor connector loose, broken, defective

  • Sensor defective

  • No data about book thickness received

  • Reconnect the connector.

  • Replace the edge press plate motor.

  • Replace the press end sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-19

B

Perfect Binder: Slide HP sensor lag error

When the slide was raised, the slide HP sensor did not go OFF after it moved 180 mm.

  • Slide motor connection loose, broken, defective

  • Motor overloaded, defective

  • Slide HP sensor connection loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the slide motor.

  • Replace the slide HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-20

B

Perfect Binder: Slide HP sensor late error

The slide HP sensor did not go ON after the slide was lowered and had enough time to move 180 mm.

  • Slide motor connection loose, broken, defective

  • Motor overloaded, defective

  • Slide HP sensor connection loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the slide motor.

  • Replace the slide HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-21

B

Perfect Binder: Book rotation HP sensor (right) lag error

  • The book rotation HP sensor did not go OFF after the book was rotated 60 degrees.

  • The book rotation HP sensor did not go OFF after the book was rotated 30 degrees.

  • Book rotation motor 1 (right) connector, loose, broken, defective

  • Motor overloaded, obstructed, defective

  • Book rotation HP sensor (right) connector loose, broken, defective

  • Reconnect the connector.

  • Replace the Book rotation motor 1 (right).

  • Replace the book rotation HP sensor (right).

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-22

B

Perfect Binder: Book rotation HP sensor (right) late error

  • The book rotation HP 1 (right) sensor did not go ON after the book was rotated 440 degrees.

  • The book rotation HP 1 (right) sensor did not go ON after the book was rotated 400 degrees.

  • The book rotation HP 1 (right) sensor did not go ON after the book was rotated 360 degrees.

  • Book rotation motor 1 (right) connector, loose, broken, defective

  • Motor overloaded, obstructed, defective

  • Book rotation HP sensor (right) connector loose, broken, defective

  • Reconnect the connector.

  • Replace the Book rotation motor 1 (right).

  • Replace the book rotation HP sensor (right).

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-23

B

Perfect Binder: Book rotation HP sensor (left) lag error

  • The book rotation HP sensor 2 (right) did not go OFF after the book was rotated 50 degrees.

  • The book rotation HP sensor 2 (left) did not go OFF after the book was rotated 50 degrees toward the cutting position.

  • Book rotation motor 2 (left) connector, loose, broken, defective

  • Motor overloaded, obstructed, defective

  • Book rotation HP sensor 2 (left) connector loose, broken, defective

  • Reconnect the connector.

  • Replace the book rotation motor 2 (left).

  • Replace the book rotation HP sensor 2 (left).

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-24

B

Perfect Binder: Book rotation HP sensor (left) late error

  • The book rotation HP 2 (left) sensor did not go ON after the book was rotated 400 degrees.

  • The book rotation HP 2 (left) sensor did not go ON after the book was rotated 400 degrees.

  • Before the book is rotated before cutting, the book rotation HP sensor 2 (left) did not go on, even after the book had been rotated twice the prescribed distance.

  • Book rotation motor 2 (left) connector, loose, broken, defective

  • Motor overloaded, obstructed, defective

  • Book rotation HP sensor 2 (left) connector loose, broken, defective

  • Reconnect the connector.

  • Replace the book rotation motor 2 (left).

  • Replace the book rotation HP sensor 2 (left).

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-25

B

Perfect Binder: Cutter front HP sensor lag error

  • At initialization, the blade did not leave the home position even after 20 mm of movement.

  • When the blade moved to the rear, the blade did not leave the home position after the length of time elapsed for 10 mm of movement.

  • Cutter motor connector loose, broken, defective

  • Motor overloaded, defective

  • Blade sensors 1, 2 connectors loose, broken, defective

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensor 1, 2.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-26

B

Perfect Binder: Cutter rear HP sensor late error

When the blade was moved to the rear, it did not arrive at the home position after 122 mm of movement.

  • Cutter motor connector loose, broken, defective

  • Motor overloaded, defective

  • Blade sensors 1, 2 connectors loose, broken, defective

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensor 1, 2.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-27

B

Perfect Binder: Cutter rear HP sensor lag error

  • When the blade moved from the rear HP sensor, it did not leave the rear HP position after 20 mm of movement toward the front.

  • When the blade moved to the front, the blade did not leave the home position after the length of time elapsed for 10 mm of movement.

  • Cutter motor connector loose, broken, defective

  • Motor overloaded, defective

  • Blade sensors 1, 2 connectors loose, broken, defective

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensor 1, 2.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-28

B

Perfect Binder: Cutter front HP sensor late error

When the blade is moved to the front, the blade did not return to blade sensor 1 after enough time had elapsed for the blade to move 122 mm.

  • Cutter motor connector loose, broken, defective

  • Motor overloaded, defective

  • Blade sensors 1, 2 connectors loose, broken, defective

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensor 1, 2.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-29

B

Perfect Binder: Cut end late error

  • During movement from front to rear during cutting, blade sensor 1 did not go ON after enough time had elapsed for the blade to move 61 mm.

  • During movement from front to rear during cutting, blade sensor 1 did not go ON after 10 sec. had elapsed.

  • Cutter motor connector loose, broken, defective

  • Motor overloaded, defective

  • Blade sensor 1 connector loose, broken defective

  • Sensor defective

  • Blade is dull, not cutting efficiently

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensor 1.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Replace the blade.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-30

B

Perfect Binder: Cut end lag error

  • During movement from rear to front during cutting, blade sensor 1 did not go OFF after enough time had elapsed for the blade to move 61 mm.

  • During movement from rear to front during cutting, blade sensor 1 did not go OFF after 10 sec. had elapsed.

  • Cutter motor connector loose, broken, defective

  • Motor overloaded, defective

  • Blade sensor 1 connector loose, broken defective

  • Sensor defective

  • Blade is dull, not cutting efficiently

  • Reconnect the connector.

  • Replace the cutter motor.

  • Replace the blade sensor 1.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Replace the blade.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-31

B

Perfect Binder: Book lift tray HP sensor lag error

During tray lifting, the book tray lift sensor did not go off after 10 sec. had elapsed.

The book lift sensor did not go off after enough time had elapsed to move the tray more than 10 mm.

  • Book lift tray motor connector loose, broken, defective

  • Motor overloaded, defective

  • Book lift tray HP sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace book lift tray motor.

  • Replace book lift tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-32

B

Perfect Binder: Book lift tray HP sensor late error

While the book lift tray was being lowered, the book lift tray HP sensor did not go on after 1.5 sec. had elapsed.

  • Book lift tray motor connector loose, broken, defective

  • Motor overloaded, defective

  • Book lift tray HP sensor connector loose, broken, defective

  • Sensor defective

  • Book jam

  • Reconnect the connector.

  • Replace book lift tray motor.

  • Replace book lift tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-33

B

Perfect Binder: Book lift tray motor rotation error

No encoder lock input received within 50 ms during operation.

  • Book lift motor connector loose, broken, defective

  • Motor defective

  • Book lift tray lock sensor connector loose, broken, defective

  • Sensor defective

  • Edge press plate, or mechanism jammed by a book

  • Reconnect the connector.

  • Replace book lift tray motor.

  • Replace the book lift tray encoder sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the edge press plate, or mechanism jammed by a book

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-34

B

Perfect Binder: Book output tray HP sensor lag error

  • The book output tray HP sensor did not go OFF within 1 sec. after it went ON.

  • The book output tray HP sensor did not go OFF after enough time had elapsed for the tray to move more than 10 mm.

  • Book output belt motor connector loose, broken, defective

  • Motor overloaded, defective

  • Book output tray HP sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the book output belt motor.

  • Replace the book output tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-35

B

Perfect Binder: Book out put tray HP sensor late error

The book output tray HP sensor did not go ON within 3.5 sec. after it went OFF.

  • Book output belt motor connector loose, broken, defective

  • Motor overloaded, defective

  • Book output tray HP sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the book output belt motor.

  • Replace the book output tray HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-36

B

Perfect Binder: Blade cradle HP sensor lag error

While the blade was retracting to the home position, the blade cradle sensor did not go OFF after enough time had elapsed for the blade to move 12 mm.

  • Blade cradle motor connector loose, broken, defective

  • Motor overloaded, defective

  • Blade cradle HP sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the blade cradle motor.

  • Remove the blade cradle HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-37

B

Perfect Binder: Blade cradle HP sensor late error

While the bladed was being lowered, the blade cradle HP sensor did not go ON after enough time had elapsed for 21 mm of movement.

  • Blade cradle motor connector loose, broken, defective

  • Motor defective

  • Blade cradle HP sensor connector loose, broken, defective

  • Sensor defective

  • Blade cradle or cutter physically jammed

  • Reconnect the connector.

  • Replace the blade cradle motor.

  • Replace the blade cradle HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the Blade cradle or cutter physically jammed

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-38

B

Perfect Binder: Book door lock error

The book door sensor was detected OFF with the book door locked.

  • Book door lock solenoid connector loose, broken, defective

  • Solenoid defective

  • Reconnect the connector.

  • Replace the book door lock solenoid.

  • Replace the book door open sensor.

  • Replace the cutter control board.

  • Replace the SOL harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-39

B

Perfect Binder: Glue heater error

The glue heater thermistor registered more that 200 degrees for more than 1 sec.

  • Glue temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-40

B

Electrical short in the gluing unit

A temperature of less than 5 degrees was detected for 1 sec. or more than 10 sec. after power on.) However, if the thermistor detected less than 100 degrees after measuring temperature at start up, temperature is checked again after 50 sec.

  • Glue temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-41

B

Perfect Binder: Glue heater startup error 1

Glue temperature thermistor did not detect a temperature of 140 degrees within 200 sec. after it detected a temperature over 50 degrees.

  • Glue temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-42

B

Perfect Binder: Low temperature detection error

After adjustment of the glue temperature, the glue temperature thermistor detected a temperature lower than 135 degrees for more than 10 sec.

  • Glue temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-43

B

Perfect Binder: High temperature detected in unit

Thermistor detected abnormal high temperature.

  • Glue abnormal temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit.

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-44

B

Perfect Binder: Thermostat error

Abnormal thermostat detection.

  • Thermostat defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-45

B

Perfect Binder: Glue level thermistor error 1

After glue warm-up completed, the glue level thermistor detected a temperature of over 170 degrees for more than10 sec.

  • Glue level thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-46

B

Perfect Binder: Glue level thermistor error 2

After glue warm-up completed, the glue level thermistor detected a temperature less than 100 degrees for more than10 sec.

  • Glue level thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-47

B

Perfect Binder: Thermistor disconnect error

The glue abnormal temperature thermistor detected a temperature of less than 5 degrees for 1 sec., or more than 10 sec. after power on. However, if the thermistor detected less than 100 degrees after measuring temperature at start up, temperature is checked again after 50 sec.

  • Glue abnormal temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-48

B

Perfect Binder: Glue level thermistor disconnect error

  • The AD value of the glue level thermistor was above 991 LSB for 10 sec.

  • Temperature adjustment mode stops if glue level sensor detects the temperature remaining below 99 degrees for more than 10 sec.

  • Because temperature adjustment began in another mode, the adjustment stopped when the error was detected and error detection stopped.

  • Error detection will not operate at temperature adjustment stop.

  • Glue level thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-49

B

Perfect Binder: Internal temperature thermistor error

The A/D value of the internal temperature thermostat was detected above 80 degrees for 1 sec.

  • Internal temperature thermistor connector loose, broken, defective

  • Thermistor defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the internal temperature thermistor.

  • Replace the slave board.

  • Replace the thermistor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-50

B

Perfect Binder: Internal temperature thermostat disconnect error

The A/D value of the internal temperature thermostat was detected below -20 degrees for 1 sec.

  • Internal temperature thermistor connector loose, broken, defective

  • Thermistor defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the internal temperature thermistor.

  • Replace the slave board.

  • Replace the thermistor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-51

B

Perfect Binder: Internal temperature thermistor error

Temperature was detected above 10°C three consecutive times (sampled every sec. for 1 min.).

  • Internal temperature thermistor connector loose, broken, defective

  • Thermistor defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the internal temperature thermistor.

  • Replace the slave board.

  • Replace the thermistor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-52

B

Perfect Binder: Glue heater startup error 2

The warm-up temperature was above the +-5°C target for the glue vat temperature. (Not detected within 100 sec. after machine warm-up.)

  • Internal temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the internal temperature thermistor.

  • Replace the gluing unit..

  • Replace the slave board.

  • Replace the thermistor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-53

B

Perfect Binder: Glue heater startup error 3

The warm-up temperature was below the +-5C target for the glue vat temperature. (Not detected within 100 sec. after machine warm-up.)

  • Internal temperature thermistor defective

  • Glue heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the internal temperature thermistor.

  • Replace the gluing unit..

  • Replace the slave board.

  • Replace the thermistor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-54

B

Perfect Binder: Glue heater startup error 4

At the end of temperature adjustment at power on, warm-up did not complete within 500 sec. The glue vat temperature did not reach the warm-up temperature within 500 sec.

  • Glue heater connector loose, broken, defective

  • Heater defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-55

B

Perfect Binder: Ambient temperature error

Ambient temperature is not within the operational range: It was between 0°C and -20C.

  • Internal temperature thermistor connector loose, broken, defective

  • Thermistor defective

  • Slave board defective

  • Reconnect the connector.

  • Check the room temperature (0°C or higher).

  • Replace the internal temperature thermistor.

  • Replace the slave board.

  • Replace the thermistor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-56

B

Perfect Binder: Glue low limit late error

The level of the glue in the vat was detected below the low limit 4 times.

  • Glue clogged, glue supply defective

  • Glue level thermistor connector loose, broken, defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

  • Check the remaining amount of glue pellets.

  • Remove the clogged glue.

  • Check the gluing unit.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-57

B

Perfect Binder: Glue high limit late error

Without glue application, and with the glue level above the low limit, the glue level thermistor did not detect the level of the glue at the high limit, even after 12 glue pellets were supplied.

  • Glue clogged, glue supply defective

  • Glue level thermistor connector loose, broken, defective

  • Slave board defective

  • Reconnect the connector.

  • Replace the gluing unit..

  • Replace the slave board.

  • Check the remaining amount of glue pellets.

  • Remove the clogged glue.

  • Check the gluing unit.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-58

B

Perfect Binder: Glue lowering level error

Without glue supply, the level of the glue detected by the glue lever thermistor did not lower away from the high limit level, even after application of 25.42 g

  • Glue clogged, glue supply defective

  • Glue level thermistor connector loose, broken, defective

  • Thermistor defective

  • Slave board defective

  • Glue application defective

  • Reconnect the connector.

  • Adjust the amount of glue application.

  • Replace the gluing unit..

  • Replace the slave board.

  • Check the gluing unit.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-59

B

Perfect Binder: Glue level thermistor adjustment value error



  • Temperature detected by glue level thermistor out of range, 128°C+-14°C for low limit.

  • Temperature detected by glue level thermistor out of range, 142°C+-10°C for high limit.

  • The glue level thermistor adjustment value for low limit is larger than the high level.

  • Glue level thermistor target value is 5°C off the values of the low and high limit.



  • Master control board EEPROM data error

  • Glue level thermistor connector loose, broken, defective

  • Thermistor defective

  • Slave board disconnected, defective



  • Reconnect the connector.

  • Re-set the value for glue level thermistor.

  • Replace the gluing unit..

  • Replace the master control board EEPROM.

  • Replace the slave board.

  • Replace the master control board.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-60

B

Perfect Binder: Timing sensor adjustment high value error

The timing sensor A/D input value was lower than 3.0 to 3.5V, the A/D input value did not go higher than 3.0 to 3.5V, even after timing sensor D/A output value was higher than 3.5V.

  • Timing sensor connector loose, broken, defective

  • Sensor defective

  • Master control board disconnected, defective

  • Reconnect the connector.

  • Clean the sensor.

  • Replace the timing sensor.

  • Replace the master control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-61

B

Perfect Binder: Cover registration sensor adjustment high value error

The cover registration sensor A/D input value was lower than 3.0 to 3.5V, the A/D input value did not go higher than 3.0 to 3.5V, even after cover registration sensor output value output was higher than 3.5V.

  • Cover registration sensor connector loose, broken, defective

  • Sensor defective

  • Master control board disconnected, defective

  • Reconnect the connector.

  • Clean the sensor.

  • Replace the cover registration sensor.

  • Replace the master control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-62

B

Perfect Binder: Cover horizontal registration sensor (S) adjustment high value error

The cover horizontal registration sensor (S) A/D input value was lower than 3.2 to 3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after cover registration sensor (S) D/A output value output was higher than 3.7V.

  • Cover horizontal registration sensor (S) connector loose, broken, defective

  • Sensor defective

  • Slave control board defective

  • Reconnect the connector.

  • Clean the sensor.

  • Replace the cover horizontal registration sensor (S).

  • Replace the slave control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-63

B

Perfect Binder: Cover horizontal registration sensor (L) adjustment high value error

The cover horizontal registration sensor (L) A/D input value was lower than 3.2 to 3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after cover horizontal registration sensor (L) D/A output value output was higher than 3.7V.

  • Cover horizontal registration sensor (L) connector loose, broken, defective

  • Sensor defective

  • Slave control board defective

  • Reconnect the connector.

  • Clean the sensor.

  • Replace the cover horizontal registration sensor (L)

  • Replace the slave control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-64

B

Perfect Binder: Signature exit sensor adjustment high value error

The signature exit sensor A/D input value was lower than 3.2 to 3.54V, the A/D input value did not go higher than 3.2 to 3.54V, even after cover registration sensor output value output was higher than 3.7V.

  • Signature exit sensor connector loose, broken, defective

  • Sensor defective

  • Slave control board disconnected, defective

  • Reconnect the connector.

  • Replace the signature exit sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-65

B

Perfect Binder: LE detect sensor adjustment high value error

The leading edge detect sensor A/D input value was lower than 3.2 to 3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after cover registration sensor A/D output value output was higher than 3.7V.

  • LE detect sensor connector loose, broken, defective

  • Sensor defective

  • Slave control board disconnected, defective

  • Reconnect the connector.

  • Replace the LE detect sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-66

B

Perfect Binder: Entrance path sensor adjustment high value error

When the entrance path sensor was adjusted, the sensor A/D input was less than 2.58 V, even after the sensor D/A output was more than 3.3V.

  • Entrance path sensor connector loose, broken, defective

  • Sensor defective

  • Cutter control board disconnected, defective

  • Reconnect the connector.

  • Replace the entrance path sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-67

B

Perfect Binder: Book registration sensor adjustment high value error

When the book registration sensor was adjusted, the sensor A/D input was less than 2.58 V, even after the sensor D/A output was more than 3.3V.

  • Book registration sensor connector loose, broken, defective

  • Cutter control board disconnected, defective

  • Reconnect the connector.

  • Replace the book registration sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-68

B

Perfect Binder: Timing sensor adjustment low value error

The timing sensor A/D input value was higher than 3.0 to 3.5V, the A/D input value did not enter the range 3.0 to 3.5V, even after timing sensor D/A output value was lower than 0.1V.

  • Timing sensor connector loose, broken, defective

  • Sensor defective

  • Master control board disconnected, defective

  • Reconnect the connector.

  • Replace the timing sensor.

  • Replace the master control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-69

B

Perfect Binder: Cover registration sensor adjustment low value error

The cover registration sensor A/D input value was higher than 3.0 to 3.5V, the A/D input value did not enter the range 3.0 to 3.5V, even after cover registration sensor D/A output value output was lowered 0.1V.

  • Cover registration sensor connector loose, broken, defective

  • Sensor defective

  • Master control board disconnected, defective

  • Reconnect the connector.

  • Replace the cover registration sensor.

  • Replace the master control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-70

B

Perfect Binder: Cover horizontal registration sensor (S) adjustment low value error

The cover horizontal registration sensor (S) A/D input value was higher than 3.2 to 3.54V, and the A/D input value did enter the range 3.2 to 3.54V, even sensor D/A output value output was lowered 0.04V.

  • Cover horizontal registration sensor (S) connector loose, broken, defective

  • Sensor defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the cver horizontal registration sensor (S).

  • Replace the slave control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-71

B

Perfect Binder: Cover horizontal registration sensor (L) adjustment low value error

The cover horizontal registration sensor (L) A/D input value was higher than 3.2 to 3.54V, and the A/D input value did enter the range 3.2 to 3.54V, even sensor D/A output value output was lowered 0.04V.

  • Cover horizontal registration sensor (L) connector loose, broken, defective

  • Sensor defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the cover horizontal registration sensor (L).

  • Replace the slave control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-72

B

Perfect Binder: Signature exit sensor adjustment low value error

The signature exit sensor A/D input value was higher than 3.2 to 3.54V, the A/D input value did not enter the range 3.2 to 3.54V, even after cover registration sensor output value output was raised 0.04V.

  • Signature exit sensor connector loose, broken, defective

  • Sensor defective

  • Slave control board disconnected, defective

  • Reconnect the connector.

  • Replace the signature exit sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-73

B

Perfect Binder: LE detect sensor adjustment low value error

The LE detect sensor A/D input value was higher than 3.2 to 3.54V, and the sensor A/D input value did not enter the range 3.2 to 3.54V, even after the sensor output value was raised 0.04V.

  • LE detect sensor connector loose, broken, defective

  • Sensor defective

  • Slave control board disconnected, defective

  • Reconnect the connector.

  • Replace the LE detect sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-74

B

Perfect Binder: Entrance path sensor adjustment low value error

When the entrance path sensor was adjusted, the sensor A/D input was higher than 2.58 V, even after the sensor D/A output was lowered to 0V.

  • Entrance path sensor connector loose, broken, defective

  • Sensor defective

  • Cutter control board disconnected, defective

  • Reconnect the connector.

  • Replace the entrance path sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-75

B

Perfect Binder: Book registration sensor adjustment low value error

When the book registration sensor was adjusted, the sensor A/D input was more than 2.58 V, even after the sensor D/A output was less than 0V.

  • Book registration sensor connector loose, broken, defective

  • Cutter control board disconnected, defective

  • Reconnect the connector.

  • Replace the book registration sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-76

B

Perfect Binder: LE detect sensor late error

The stack was late for gluing to the cover because there was no stack transport end sensor from the slave control board and there was no signal that the LE detect sensor had signaled to arrival of the stack.

  • LE detect sensor connector loose, broken, defective

  • Sensor defective

  • Reconnect the connector.

  • Replace the signature exit roller motor.

  • Replace the LE detect sensor.

  • Replace the slave control board.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Replace the harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-77

B

Perfect Binder: Trim unit entrance sensor late error



The stack was late arriving because the trim unit entrance sensor did not go ON even after a transport end signal was received.



  • Signature jam occurred between the cover transport unit and signature rotation unit.

  • Trim unit entrance sensor defective

  • Signature exit roller motor defective

  • Slave control board defective

  • Cutter control board defective

  • Connector loose, broken, defective



  • Reconnect the connector.

  • Replace the signature exit roller motor.

  • Replace the trim unit entrance sensor.

  • Replace the slave control board.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753- 78

B

Perfect Binder: Book registration sensor late error

At the start of cutter registration, the book registration did not go ON.

  • Signature jam occurred in the signature rotation unit.

  • Book registration sensor defective

  • Connector loose, broken, defective

  • Cutter control board defective

  • Reconnect the connector.

  • Replace the book registration sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-79

B

Perfect Binder: Signature exit sensor lag error

When the power was turned on, the cover path was closed and the signature exit sensor detected paper present, but the LE detect sensor had detected no paper present.

  • Signature exit sensor defective

  • Signature jam occurred in the cover transport unit when the power was turned on.

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the signature exit sensor.

  • Replace the leading edge sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-80

B

Perfect Binder: Entrance path sensor late error



During the automatic exit operation, the entrance path sensor could not detect any paper within 6860 ms after gluing and stack transport started.



  • Signature jam occurred between the cover transport unit and signature rotation unit during the automatic exit operation.

  • Trim unit entrance sensor defective

  • Stack transport roller defective

  • Connector loose, broken, defective

  • Slave control board defective



  • Reconnect the connector.

  • Replace the signature exit roller motor.

  • Replace the trim unit entrance sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-81

B

Perfect Binder: Main grip late error

There was no stack received from the sub grip unit; the main grip signature sensor detected no stack.

  • Signature jam occurred in the sub grip unit.

  • Signature move motor defective

  • Main grip signature sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the signature move motor.

  • Replace the main grip signature sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-82

B

Perfect Binder: Trim unit entrance sensor lag error

At the end of initialization at power on, the entrance path sensor went ON.

  • Signature jam occurred in the trim unit.

  • Trim unit entrance sensor defective

  • Connector loose, broken, defective

  • Cutter control board defective

  • Reconnect the connector.

  • Replace the trim unit entrance sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-83

B

Perfect Binder: Book registration sensor lag error

  • Book registration sensor detected ON at the end of initialization after power on.

  • Book registration sensor detected ON at the end of automatic exit operation.

  • Book registration sensor detected ON at the end of book binding and automatic exit.

  • Book registration sensor could detect no stack at fore edge cutting.

  • Book registration sensor detected ON at end of grip operation during book binding.

  • Signature jam occurred in the book lift tray

  • Book registration sensor defective

  • Connector loose, broken, defective

  • Cutter control board defective

  • Reconnect the connector.

  • Replace the book registration sensor.

  • Replace the cutter control board.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-84

B

Perfect Binder: Book arrival sensor lag error

Not detected

  • Sensor defective

  • Book failed to reach output tray

  • Fore edge trim scraps fell into output area

  • Not detected

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-85

B

Perfect Binder: Trimming jam error

  • The edge press plate HP sensor remained OFF after disposing of the trimmed paper and the trimmings buffer was moved 19 mm to the right.

  • After the trimmings buffer door was opened and closed to check for paper scraps, the machine detected paper scrap jam 3 times (and issued the alarm after the 2nd detection).

  • There are scraps in the trimmings buffer and at the edge press plate.

  • Edge press plate HP sensor defective

  • Trimmings buffer motor defective

  • Connector loose, broken, defective

  • Cutter control board defective

  • Reconnect the connector.

  • Replace the trimmings buffer motor.

  • Replace the edge press plate HP sensor.

  • Replace the cutter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the trimming jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-86

B

Perfect Binder: Sub grip unit lag error

When the sub grip unit was checked for the presence of paper, no paper could be detected even after opening the sub grip unit.

  • Paper remains in the sub grip unit.

  • Sub grip signature sensor defective

  • Sub gripper motor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the sub gripper motor.

  • Replace the sub grip signature sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-87

B

Perfect Binder: Main grip unit lag error

Although cutter retracted, the absence of paper could not be detected.

  • Paper remains in the main grip unit

  • Main grip signature sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Signature exit roller motor defective

  • Reconnect the connector.

  • Replace the main grip signature sensor.

  • Replace the slave control board.

  • Replace the sensor harness.

  • Clear the signature jam.

  • Replace the signature exit roller motor.

  • Replace the motor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-88

B

Perfect Binder: Signature thickness sensor minimum value error

When the result of the signature thickness detection (A/D value) was adjusted, the minimum value (0 mm) was smaller than the A/D value of -30.

  • Signature thickness sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Master control board defective

  • EEPROM on the master board defective

  • Reconnect the connector.

  • Specify the signature thickness again.

  • Replace the signature thickness sensor.

  • Replace the EEPROM on the master board.

  • Replace the slave control board.

  • Replace the master control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC753-89

B

Perfect Binder: Signature thickness sensor maximum value error

When the result of the signature thickness detection (A/D value) was adjusted, the maximum value (25mm) was smaller than the A/D value.

  • Signature thickness sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Master control board defective

  • EEPROM on the master board defective

  • Reconnect the connector.

  • Specify the signature thickness again.

  • Replace the signature thickness sensor.

  • Replace the EEPROM on the master board.

  • Replace the slave control board.

  • Replace the master control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-10

B

Perfect Binder: Signature thickness sensor value unstable error

The signature thickness reading did not change, even after the main grip unit opened and closed.

  • Signature thickness sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Master control board defective

  • EEPROM on the master board defective

  • Reconnect the connector.

  • Specify the signature thickness again.

  • Replace the signature thickness sensor.

  • Replace the EEPROM on the master board.

  • Replace the slave control board.

  • Replace the master control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-11

B

Perfect Binder: Glue vat roller motor error

The glue vat roller rotation sensor could not detect rotation of the glue vat roller motor within 1200 ms of motor operation.

  • Glue vat roller motor defective

  • Glue vat roller rotation sensor connector defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the vat roller motor.

  • Replace the vat roller rotation sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-12

B

Perfect Binder: Glue roller HP sensor late error

During glue supply, the glue roller HP sensor did not go ON, even though the glue roller motor was operating for 1000 ms.

  • Glue pellets jammed

  • Glue supply motor defective

  • Glue roller HP sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the glue supply motor.

  • Replace the glue roller HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-13

B

Perfect Binder: Glue roller HP sensor lag error

During glue supply, the glue roller HP sensor did not go OFF, even though the glue roller motor was operating for 2400 ms.

  • Glue pellets jammed

  • Glue supply motor defective

  • Glue roller HP sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the glue supply motor.

  • Replace the glue roller HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-14

B

Perfect Binder: Front door lock error

Front door lock release sensor did not go off, even though the door was locked.

  • Front door solenoid defective

  • Front door lock release sensor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the front door solenoid.

  • Replace the front door lock release sensor.

  • Replace the master control board.

  • Replace the solenoid harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-15

B

Perfect Binder: Front door lock release error

The front door lock release sensor did not go ON, even though the door was unlocked.

  • Front door solenoid defective

  • Front door lock release sensor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the front door solenoid.

  • Replace the front door lock release sensor.

  • Replace the master control board.

  • Replace the solenoid harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-16

B

Perfect Binder: Front door force open error

The front door open was detected open, even though it was locked.

  • Front door switch defective

  • Front door solenoid defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the front door solenoid.

  • Replace the front door switch.

  • Replace the master control board.

  • Replace the solenoid harness.

  • Replace the switch harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-17

B

Perfect Binder: Switchback flapper HP sensor late error

During the switchback flapper lift operation, the switchback flapper HP sensor did not go ON, even though the switchback flapper motor operated long enough for lifting through an arc of 50 degrees

  • Switchback flapper HP sensor defective

  • Switchback flapper motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the switchback flapper motor.

  • Replace the switchback flapper HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-18

B

Perfect Binder: Switchback flapper HP sensor lag error

During the switchback flapper lift operation, the switchback flapper HP sensor did not go OFF, even though the switchback flapper motor operated long enough for lowering through an arc of 150 degrees

  • Switchback flapper HP sensor defective

  • Switchback flapper motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the switchback flapper motor.

  • Replace the switchback flapper HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-19

B

Perfect Binder: TE press lever HP sensor late error

When the trailing edge press lever was released, the TE press lever HP sensor did not go ON, even though the TE press lever motor operated long enough to move the lever through and arc of 30 degrees.

  • TE press lever HP sensor defective

  • TE press lever motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the TE press lever motor.

  • Replace the TE press lever HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-20

B

Perfect Binder: TE press lever HP sensor lag error

When the trailing edge press lever was released, the TE press lever HP sensor did not go OFF, even though the TE press lever motor operated long enough to move the lever through and arc of 20 degrees.

  • TE press lever HP sensor defective

  • TE press lever motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the TE press lever motor.

  • Replace the TE press lever HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-21

B

Perfect Binder: Jog fence front HP sensor late error

The front jog fence HP sensor did not go ON, even thought the jog fence motor operated long enough for 60 mm of feed.

  • Jog fence front HP sensor defective

  • Jog fence front motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the jog fence front motor.

  • Replace the jog fence front HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-22

B

Perfect Binder: Jog fence front HP sensor lag jam

While small-size paper was being jogged, the jog fence front HP sensor did not go OFF after the front jog fence motor operated long enough for 40 mm of feed.

  • Jog fence front HP sensor defective

  • Jog fence front motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the jog fence front motor.

  • Replace the jog fence front HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-23

B

Perfect Binder: Jog fence large HP sensor late error

While large-size paper was being jogged, the front jog fence large HP sensor did not go ON, even though the jog fence front motor operated long enough for 70mm of feed.

  • Jog fence front large HP sensor defective

  • Jog fence front motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the jog fence front motor.

  • Replace the jog fence front large HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-24

B

Perfect Binder: Jog fence front large HP sensor lag error

While large-size paper was being jogged, the jog fence front large HP sensor did not go OFF after the front jog fence motor operated long enough for 20 mm of feed.

  • Jog fence front large HP sensor defective

  • Jog fence front motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the jog fence front motor.

  • Replace the jog fence front large HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-25

B

Perfect Binder: Jog fence rear HP sensor late error

While jogging small-size paper, the rear jog fence HP sensor did not go ON, even though the jog fence motor operated long enough for 60 mm of feed.

  • Jog fence rear HP sensor defective

  • Jog fence rear motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the jog fence rear motor.

  • Replace the jog fence rear HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-26

B

Perfect Binder: Jog fence rear HP sensor lag jam

While small-size paper was being jogged, the jog fence rear HP sensor did not go OFF after the rear jog fence motor operated long enough for 40 mm of feed.

  • Jog fence rear HP sensor defective

  • Jog fence rear motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the jog fence rear motor.

  • Replace the jog fence rear HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-27

B

Perfect Binder: Jog fence rear large HP sensor late error

While large-size paper was being jogged, the rear jog fence large HP sensor did not go ON, even though the jog fence rear motor operated long enough for 70mm of feed.

  • Jog fence rear large HP sensor defective

  • Jog fence rear motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the jog fence rear motor.

  • Replace the jog fence rear large HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-28

B

Perfect Binder: Jog fence rear large HP sensor lag error

While large-size paper was being jogged, the jog fence rear large HP sensor did not go OFF after the rear jog fence motor operated long enough for 20 mm of feed.

  • Jog fence rear large HP sensor defective

  • Jog fence rear motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the jog fence rear motor.

  • Replace the jog fence rear large HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-29

B

Perfect Binder: Switchback roller HP sensor late error

During the switchback roller lift operation, the switchback roller HP sensor did not go ON, even though the switchback roller lift motor operated long enough for lifting through an arc of 40 degrees.

  • Switchback roller HP sensor defective

  • Switchback roller lift motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the switchback roller lift motor.

  • Replace the switchback roller HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-30

B

Perfect Binder: Switchback roller HP sensor lag error

During the switchback roller lowering, the switchback roller HP sensor did not go OFF, even though the switchback roller lift motor operated long enough for lowering through an arc of 40 degrees.

  • Switchback roller HP sensor defective

  • Switchback roller lift motor defective

  • Connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the switchback roller lift motor.

  • Replace the switchback roller HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-31

B

Perfect Binder: Stacking tray lower limit late error

When the stacking tray was lowered, the tray lower limit sensor did not go ON after the stacking tray lift motor had operated long enough for 90 mm of lift.

  • Tray lower limit sensor defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the tray lower limit sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-32

B

Perfect Binder: Stacking tray low limit lag error

When the stacking tray was raised, the tray lower limit sensor did not go OFF after the stacking tray lift motor had operated long enough for 30mm of lift.

  • Tray lower limit sensor defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the tray lower limit sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-33

B

Perfect Binder: Paper detect sensor (front) detection error

When the stacking tray was raised, the paper detect sensor (front) did not go ON, even after the stacking tray overflow sensor went ON and the stacking tray lift motor had operated for 30 mm of lift.

  • Paper detect sensor (front) defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the paper detect sensor (front).

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-34

B

Perfect Binder: Perfect Binder: Paper detect sensor (front) no paper detection error

When the stacking tray was lowered, the tray lower limit sensor did not go OFF after the stacking tray lift motor had operated long enough for 10mm of lowering.

  • Paper detect sensor (front) defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the paper detect sensor (front).

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-35

B

Perfect Binder: Paper detect sensor (rear) paper detection error

When the stacking tray was raised, the paper detect sensor (rear) did not go ON, even after the stacking tray overflow sensor went ON and the stacking tray lift motor had operated for 40 mm of lift.

  • Paper detect sensor (rear) defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the paper detect sensor (rear).

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-36

B

Perfect Binder: Paper detect sensor (rear) no paper detection error

When the stacking tray was lowered, the paper detect sensor (rear) did not go OFF after the stacking tray lift motor had operated long enough for 10mm of lowering.

  • Paper detect sensor (rear) defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the paper detect sensor (rear).

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-37

B

Perfect Binder: Stack overflow sensor detection late error

When the stacking tray was raised, the stack overflow sensor did not go OFF after the stacking tray lift motor had operated long enough for 70mm lowering.

  • Stack overflow sensor defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the stack overflow sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-38

B

Perfect Binder: Stacking tray low limit sensor error 1

The stacking tray low limit sensor and the stack overflow sensor went ON at the same time.

  • Tray lower limit sensor defective

  • Stack overflow sensor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the tray lower limit sensor.

  • Replace the stack overflow sensor.

  • Replace the master control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-39

B

Perfect Binder: Stack overflow sensor detection position lag error

When the tray was lowered to allow removal of the booklets, the stack overflow

sensor did not go OFF, even after the stacking tray lift motor had operated long enough for 40mm of lift.

  • Stack overflow sensor defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the stack overflow sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-40

B

Perfect Binder: Stacking tray low limit sensor error 2

When the stacking tray was lifted, the stack overflow sensor did not go OFF, even though the either (or both) the paper detect sensor (front) or the paper detect sensor (rear) were on while the stacking tray empty sensor was OFF.

  • Tray empty sensor defective

  • Paper detect sensors (front, rear, or both) defective

  • Stack overflow sensor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the tray empty sensor.

  • Replace the paper detect sensor (front).

  • Replace the paper detect sensor (rear).

  • Replace the stack overflow sensor.

  • Replace the master control board.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-41

B

Perfect Binder: Stack tray HP sensor late error

When the tray moved to the home position, the HP sensor did not go ON after enough time for 70mm of movement had elapsed.

  • Stack tray HP sensor defective

  • Stacking tray lift motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stacking tray lift motor.

  • Replace the stack tray HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-42

B

Perfect Binder: Stack tray HP sensor lag error

When the tray moved from the home position, the HP sensor did not go OFF after enough time for 10mm of movement had elapsed.

  • Stack tray HP sensor defective

  • Stacking tray motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stacking tray motor.

  • Replace the stack tray HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-43

B

Perfect Binder: Stack weight move HP sensor late error

When the tray moved to the home position, the stack weight move HP sensor did not go ON after enough time for 70mm of movement had elapsed.

  • Stack weight HP sensor defective

  • Stack weight motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stack weight motor.

  • Replace the stack weight HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-44

B

Perfect Binder: Stack weight HP sensor lag error

During movement away from the HP sensor, the HP sensor did not go OFF after enough time for 10mm of movement had elapsed.

  • Stack weight HP sensor defective

  • Stack weight motor defective

  • Harness connector loose, broken, defective

  • Master control board defective

  • Reconnect the connector.

  • Replace the stack weight motor.

  • Replace the stack weight HP sensor.

  • Replace the master control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-45

B

Perfect Binder: Sub grip HP sensor late error

During the sub grip lift operation, the sub grip upper HP sensor did not go ON, even though the sub grip lift motor had operated for 4110 ms.

  • Sub grip lift motor defective

  • Sub grip upper HP sensor defective

  • Harness connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the sub grip lift motor.

  • Replace the Sub grip upper HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-46

B

Perfect Binder: Sub grip HP sensor lag error

During sub grip lowering, the sub grip lower HP sensor did not go OFF, even though the sub grip lift motor had operated for 240 ms.

  • Sub grip lift motor defective

  • Sub grip upper HP sensor defective

  • Harness connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the sub grip lift motor.

  • Replace the Sub grip upper HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-47

B

Perfect Binder: Sub grip size HP sensor late error

When the sub grip unit opened horizontally, the size move HP sensor did not go ON, even after the size move motor had operated for 726 ms, or operated long enough for 108.75 mm of movement.

After the sub grip unit moved to the horizontal release position, the sub grip size HP sensor was already OFF.

  • Sub grip size motor defective

  • Sub grip size HP sensor defective

  • Harness connector, loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the sub grip size motor.

  • Replace the sub grip size HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-48

B

Perfect Binder: Sub grip size HP sensor lag error



  • When the sub grip unit closed horizontally, the size move HP sensor did not go OFF, even after the size move motor had operated for 500 ms, or operated long enough for 108.75 mm of movement.

  • After the sub grip unit moved from the horizontal close position to the open position, the size shift HP sensor was already ON.



  • Sub grip size motor defective

  • Sub grip size HP sensor defective

  • Harness connector, loose, broken, defective

  • Slave control board defective



  • Reconnect the connector.

  • Replace the sub grip size motor.

  • Replace the sub grip size HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-49

B

Perfect Binder: Sub grip open position late error

At the start of the sub grip open operation, the SG open sensor did not go ON, even after the SG motor had operated for 1500 ms.

  • SG motor drive board defective

  • SG open sensor defective

  • Harness connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the SG motor.

  • Replace the SG open sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-50

B

Perfect Binder: Sub grip open position lag error

At the start of the sub grip close operation, the SG open sensor did not go OFF, even after the SG motor had operated for 500 ms.

  • SG motor defective

  • SG open sensor defective

  • Harness connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the SG motor.

  • Replace the SG open sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-51

B

Perfect Binder: Sub grip close position late error

At the start of the sub grip close operation, the SG close sensor did not go ON, even after the SG motor had operated for 1500 ms.

  • SG motor defective

  • SG close sensor defective

  • Harness connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the SG motor.

  • Replace the SG close sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-52

B

Perfect Binder: Sub grip close position lag error

At the start of the sub grip open operation, the SG close sensor did not go OFF, even after the SG motor had operated for 500 ms.

  • SG motor defective

  • SG close sensor defective

  • Harness connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the SG motor.

  • Replace the SG close sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-53

B

Perfect Binder: Main grip HP sensor late error

  • During main grip lift, the MG HP sensor did not go ON, even though the main grip lift motor had operated for 6185 ms.

  • MG HP sensor did not go OFF when the main grip moved from up position to down position.

  • MG lift motor defective

  • MG HP sensor defective

  • Connector harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-54

B

Perfect Binder: Main grip HP sensor lag error



  • During main grip lowering, the MG HP sensor did not go OFF, even though the main grip lift motor had operated for 1455 ms.

  • MG HP sensor did not go ON when the main grip moved from down position to up position.



  • MG lift motor defective

  • MG HP sensor defective

  • Connector harness loose, broken, defective

  • Slave control board defective



  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-55

B

Perfect Binder: Main grip press sensors (s) position late error

When lifting from main grip signature registration position, MG press sensors did not go ON, even though the MG lift motor had operated for 95 ms.

  • MG lift motor defective

  • MG press sensors defective

  • Connector harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG press sensor (S).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-56

B

Perfect Binder: Main grip press sensor (S) position lag error

When lowering to main grip signature registration position, MG press sensor (S) did not go OFF, even though the MG lift motor had operated for 5640 ms.

  • MG lift motor defective

  • MG press sensor (S) defective

  • Connector harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG press sensor (S).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-57

B

Perfect Binder: Main grip press sensor (L) position late error

When lowering cover in main grip to press position, MG press sensor (L) did not go ON, even though the MG lift motor had operated for 6185 ms.

  • MG lift motor defective

  • MG press sensor (L) defective

  • Connector harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG press sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-58

B

Perfect Binder: Main grip press sensor (L) position lag error

When raising cover in main grip from press position, MG press sensor (L) did not go OFF, even though the MG lift motor had operated for 95 ms.

  • MG lift motor defective

  • MG press sensor (L) defective

  • Connector harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG press sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-59

B

Perfect Binder: Signature exit sensor late error

When signature was passed from main grip to signature exit roller, signature exit sensor did not go ON after MG lift motor moved to signature turnover position.

  • MG lift motor defective

  • Signature exit sensor defective

  • Signature out of position, snagged on main grip

  • Connector harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the signature exit sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-60

B

Perfect Binder: Main grip HP sensor (L) late error

During main grip lift, the MG HP sensor (L) did not go ON, even though the main grip lift motor had operated for 6185 ms.

  • MG lift motor defective

  • MG HP sensor (L) defective

  • Connector harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG HP sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-61

B

Perfect Binder: Main grip HP sensor (L) lag error

During main grip lowering, the MG HP sensor (L) did not go OFF, even though the main grip lift motor had operated for 1455 ms.

  • MG lift motor defective

  • MG HP sensor (L) defective

  • Connector harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG lift motor.

  • Replace the MG HP sensor (L).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-62

B

Perfect Binder: Main grip open sensor (R) late error

At the start of the main grip open operation, the MG open sensor (R) did not go ON, even after the MG motor (R) had operated for 3000 ms.

  • Main grip motor (R) defective

  • MG open sensor (R) defective

  • Connector or harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the main grip motor (R).

  • Replace the main grip open sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-63

B

Perfect Binder: Main grip open sensor (R) lag error

At the start of the main grip close operation, the MG open sensor (R) did not go OFF, even after the MG motor (R) had operated for 500 ms.

  • Main grip motor (R) defective

  • Main grip open sensor (R) defective

  • Connector or harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the main grip motor (R).

  • Replace the main grip open sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-64

B

Perfect Binder: Main grip close sensor (R) late error

At the start of the main grip close operation, the MG close sensor (R) did not go ON, even after the MG motor (R) had operated for 3000 ms.

  • Main grip motor (R) defective

  • Main grip close sensor (R) defective

  • Connector or harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the main grip motor (R).

  • Replace the main grip close sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-65

B

Perfect Binder: Main grip close sensor (R) lag error

At the start of the main grip close operation, the MG close sensor (R) did not go OFF, even after the MG motor (R) had operated for 500 ms.

  • Main grip motor (R) defective

  • Main grip close sensor (R) defective

  • Connector or harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the main grip motor (R).

  • Replace the main grip close sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-66

B

Perfect Binder: Main grip motor (R) rotation error

At the start of the main grip open operation, the MG encoder sensor (R) was not detected on/off, even after the MG motor (R) had operated for 200 ms.

  • Main grip motor (R) defective

  • Main grip encoder sensor (R) defective

  • Connector or harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the main grip motor (R).

  • Replace the main grip encoder sensor (R).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-67

B

Perfect Binder: Main grip open sensor (F) late error

At the start of the main grip open operation, the MG open sensor (F) did not go ON, even after the MG motor (R) had operated for 3000 ms.

  • Main grip motor (F) defective

  • MG open sensor (F) defective

  • Connector or harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG motor (F).

  • Replace the MG open sensor (F).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-68

B

Perfect Binder: Main grip open sensor (F) lag error

At the start of the main grip close operation, the MG open sensor (F) did not go OFF, even after the MG motor (F) had operated for 500 ms.

  • MG motor (F) defective

  • MG open sensor (F) defective

  • Connector or harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG motor (F).

  • Replace the MG open sensor (F).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-69

B

Perfect Binder: Main grip close sensor (F) late error

At the start of the main grip open operation, the MG close sensor (F) did not go ON, even after the MG motor (F) had operated for 3000 ms.

  • MG motor (F) defective

  • MG close sensor (F) defective

  • Connector or harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG motor (F).

  • Replace the MG close sensor (F).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-70

B

Perfect Binder: Main grip close sensor (F) lag error

At the start of the main grip open operation, the MG close sensor (F) did not go OFF, even after the MG motor (F) had operated for 500 ms.

  • MG motor (F) defective

  • MG close sensor (F) defective

  • Connector or harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG motor (F).

  • Replace the MG close sensor (F).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-71

B

Perfect Binder: Main grip motor (F) rotation error

At the start of the main grip open/close operation, the MG encoder sensor (F) was not detected on/off, even after the MG motor (F) had operated for 200 ms.

  • MG motor (F) defective

  • MG encoder sensor (F) defective

  • Connector or harness loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the MG motor (F).

  • Replace the MG encoder sensor (F).

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-72

B

Perfect Binder: Signature exit path HP sensor late error

During signature output roller separation, the signature exit path sensor did not go ON, even after the signature exit path motor was ON for 750 ms.

  • Signature path exit motor defective

  • Signature path exit HP sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the signature path exit motor.

  • Replace the signature path exit HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-73

B

Perfect Binder: Signature exit path HP sensor lag error

During signature exit roller nip operation, the signature exit path sensor did not go OFF, even after the signature exit path motor was OFF for 300 ms.

  • Signature path exit motor defective

  • Signature path exit HP sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the signature path exit motor.

  • Replace the signature path exit HP sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-74

B

Perfect Binder: Signature path exit press sensor late error

During signature exit roller nip operation, the signature exit path exit press sensor did not go ON, even after the signature exit path motor operated for 300 ms.

  • Signature path exit motor defective

  • Signature path exit press sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the signature path exit motor.

  • Replace the signature path exit press sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-75

B

Perfect Binder: Signature path exit press sensor late error

During signature output roller separation, the signature exit path press sensor did not go OFF, even after the signature exit path motor was ON for 300 ms.

  • Signature path exit motor defective

  • Signature path exit press sensor defective

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the signature path exit motor.

  • Replace the signature path exit press sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-76

B

Perfect Binder: Leading edge sensor late error

When signature exited at signature path exit roller, the leading edge sensor did not go ON, even after the signature exit roller motor operated long enough to feed the book 45 mm.

  • Signature exit roller motor defective

  • Leading edge sensor defection

  • Signature jam

  • Connector loose, broken, defective

  • Slave control board defective

  • Reconnect the connector.

  • Replace the signature exit roller motor.

  • Replace the leading edge sensor.

  • Replace the slave control board.

  • Replace the motor harness.

  • Replace the sensor harness.

  • Clear the signature jam

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-77

B

Perfect Binder: Drive switch motor error (down to up)

The rack where the drive gear is mounted did not retract from the drive switch sensor after the drive switch motor operated for 3 s.

  • Drive switch motor defective

  • Drive switch sensor defective

  • Connector loose, broken, defective

  • Inserter control board defective

  • Reconnect the connector.

  • Replace the drive switch motor.

  • Replace the drive switch sensor

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-78

B

Perfect Binder: Drive switch motor error (up to down)

The rack where the drive gear is mounted was late arriving at the drive switch sensor after the drive switch motor operated for 3 s.

  • Drive switch motor defective

  • Drive switch sensor defective

  • Connector loose, broken, defective

  • Inserter control board defective

  • Reconnect the connector.

  • Replace the drive switch motor.

  • Replace the drive switch sensor

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-79

B

Perfect Binder: Upper tray low position late error

The upper tray did not leave the lower limit sensor after the upper tray lift motor had operated for 5 s.

  • Upper tray lift motor defective

  • Upper tray low limit sensor defective

  • Connector loose, broken, defective

  • Inserter control board defective

  • Reconnect the connector.

  • Replace the upper tray lift motor.

  • Replace the upper tray low limit sensor

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-80

B

Perfect Binder: Upper tray feed position late error

The upper tray did not arrive at the PICK sensor after the upper tray lift motor had operated for 5 s.

  • Upper tray lift motor defective

  • Upper tray PICK sensor defective

  • Connector loose, broken, defective

  • Inserter control board defective

  • Reconnect the connector.

  • Replace the upper tray lift motor.

  • Replace the upper tray PICK sensor

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-81

B

Perfect Binder: Lower tray low position lag error

The lower tray did not leave the low limit sensor after the lower tray lift motor had operated for 5 s.

  • Lower tray lift motor defective

  • Upper tray low limit sensor defective

  • Connector loose, broken, defective

  • Inserter control board defective

  • Reconnect the connector.

  • Replace the lower tray lift motor.

  • Replace the upper tray low limit sensor

  • Replace the inserter control board.

  • Replace the motor harness.

  • Replace the sensor harness.

After the repairs, cancel the low performance mode, and then turn the power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC754-82

B

Perfect Binder: Lower tray paper feed position late error

The lower tray did not leave the lower tray paper feed sensor after the lower tray lift motor had operated for 5 s.

The lower tray did not arrive at the lower tray paper feed sensor after the lower tray lift motor had operated for 5 s.

  • Lower tray lift motor defective

  • Lower tray PICK sensor defective

  • Connector loose, broken, defective

  • Inserter control board defective