- Operation panel unit (Operation Panel Unit)
 - Micro computer board (Micro Computer Board)
 - Speaker [A] (
×2)
 - Lift the fastener of the LCD I/F cable.
 - LCD I/F cable (cable ×1)
 - Remove the tapes for fixing the microphone harness (tape ×3).
 - LCD [A] (
×4)
 
- After replacing the LCD, perform the following checks.
- LCD Check (LCD Check)
 - TouchPanel Check (TouchPanel Check)
 
 - Perform "TouchPanel Calibration" (TouchPanel Calibration) and "MultiTouch Calibration" (MultiTouch Calibration) of the Self Check function.