When entering the Input Check mode, 8 digits display the result for a section. Each digit corresponds to a different device as shown in the table.
Bit No. | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Result | 0 or 1 | 0 or 1 | 0 or 1 | 0 or 1 | 0 or 1 | 0 or 1 | 0 or 1 | 0 or 1 |
SP | Description | Reading | |
---|---|---|---|
0 | 1 | ||
5-803-001 | Exit Full Sensor | Paper not detected | Paper detected |
5-803-002 | Du On Sensor | Paper not detected | Paper detected |
5-803-003 | Fuser Exit On Sensor | Paper not detected | Paper detected |
5-803-004 | Regist Sens On Sensor | Paper not detected | Paper detected |
5-803-005 | MPF Jam On Sensor | Paper not detected | Paper detected |
5-803-010 | Outside temperature | - | - |
5-803-011 | Outside humidity | - | - |
5-803-012 | LSU temperature KM | - | - |
5-803-013 | LSU temperature CY | - | - |
5-803-014 | Developer temperature | - | - |
5-803-018 | IPU Version | - | - |
5-803-104 | SDCU Set | Set | Not set |