SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC508-00 |
B |
By-pass bottom plate operation error |
The signal from the by-pass bottom plate HP Sensor has not changed (that is, the signal has not changed from ON to OFF or vice versa) for 4 seconds or more after the start of reverse Paper Feed Unit rotation. If the error is detected three times in succession, the appropriate SC number is displayed on the operation panel unit. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC520-00 |
D |
Main motor error |
When the main motor is driven, the lock (state of rotation) signal is checked every 100 milliseconds. If the machine detects the lock signal in the High status 20 times in succession, it reports this error. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC525-01 |
D |
Tray 2 paper feed motor error |
When the machine has an optional tray, the lock signal from the paper feed motor in the tray 2 is received. |
||
|
||
|
||
SC525-02 |
D |
Tray 2 paper feed motor error |
When the machine has two optional trays, the lock signal from the paper feed motor in the tray 2 is received. |
||
|
||
|
||
SC525-03 |
D |
Tray 2 paper feed motor error |
When the machine has three optional trays, the lock signal from the paper feed motor in the tray 2 is received. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC526-01 |
D |
Tray 3 paper feed motor error |
When the machine has two optional trays, the lock signal from the paper feed motor in the tray 3 is received. |
||
|
||
|
||
SC526-02 |
D |
Tray 3 paper feed motor error |
When the machine has three optional trays, the lock signal from the paper feed motor in the tray 3 is received. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC527-01 |
D |
Tray 4 paper feed motor error |
When the machine has three optional trays, the lock signal from the paper feed motor in the tray 4 is received. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC531-00 |
D |
PCDU Cooling fan error |
The fan motor lock (rotating state) signal is sampled at 100 ms intervals and the machine fails to receive the lock signal 50 times in succession. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC532-00 |
D |
PSU Cooling fan error |
The fan motor lock (rotating state) signal is sampled at 100 ms intervals and the machine fails to receive the lock signal 50 times in succession. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC541-00 |
A |
Broken fusing (Center) thermistor wire |
The condition whereby the temperature is -20°C or less for 5 seconds has been detected 10 times or more. |
||
|
||
Clear the SP: fusing SC. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC542-01 |
A |
Fusing lamp (Center) thermistor not reloaded 1 |
The heater thermistor has increased by less than 2.0 degrees in 1.5 seconds 5 times in a row. |
||
|
||
Clear the SP: fusing SC. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC542-02 |
A |
Fusing lamp (Center) thermistor not reloaded 2 |
The heater (Center) thermistor does not reach the reload temperature 50 seconds after the start of motor rotation. |
||
|
||
Clear the SP: fusing SC. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC543-00 |
A |
Fusing (Center) thermopile high-temperature detected (software) |
The temperature is detected to stay at 245°C or higher for one second. |
||
|
||
Clear the SP: fusing SC. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC544-00 |
A |
Fusing (Center) thermopile high-temperature detected (hardware) |
The hardware high-temperature error Sensor flag is detected. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC545-00 |
A |
Fusing (Center) heater stay ON |
The thermistor (center) has not detected the target temperature, even after the fusing heater stays ON for more than 30 seconds after reloading. |
||
|
||
Clear the SP: fusing SC. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC547-01 |
D |
Zero-crossing error (adhered relay contact) |
When the fusing relay is in an OFF state, a "zero-crossing interrupt request" occurs in 50 ms. |
||
Damaged fusing relay (adhered contact) Failed fusing relay driving circuit |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC547-02 |
D |
Zero-crossing error (bad relay contact) |
If a "zero-crossing interrupt request" does not occur when the fusing relay is in an ON state, an error results. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC547-03 |
D |
Zero-crossing error (low frequency error) |
The number of zero-crossing interrupts does not reach a certain value in 500 ms. |
||
The frequency of the commercial power supply line is unstable. |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC551-00 |
A |
Thermistor broken (Edge) |
While a fusing heater works, temperatures of -20°C or less during a consecutive 9 seconds are detected more than 10 times. |
||
|
||
Clear the SP: fusing SC |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC553-00 |
A |
Fusing (Edge) thermistor high-temperature detected (software) |
While a fusing heater works, temperatures of 255°C or more are detected during 1 second. |
||
Resistor failure: Thermistor (Center) |
||
Clear the SP: fusing SC |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC554-00 |
A |
Fusing (Edge) thermistor high-temperature detected (Hardware) |
Temperatures of 257°C or more are detected. |
||
|
||
Clear the SP: fusing SC. Replace PSU when triac is blown. Replace engine board and/or fusing thermistor. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC557-00 |
C |
Zero-crossing frequency exceeded |
The number of zero-crossing interrupts exceeds a certain value in 500 ms. |
||
The frequency of the commercial power supply line is unstable or noise occurs. |
||
None |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC559-00 |
A |
Fusing jam detected 3 times in succession |
Fusing jam is detected three times in succession. |
||
Paper is wrapped around the fusing roller. |
||
Clear the SP: fusing SC. |