SC400 (Image Processing – 2)

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC440-00

D

High voltage output error: Transfer unit

This SC is issued if the engine board detects a short in the power pack 10 times consecutively.

Open circuit (+) / Short circuit (-)

  • Turn the main power off/on.

  • Replace the board

  • Check the connector connection.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC460-00

D

High voltage output error: Paper separation

This SC is issued if the engine board detects a short 10 times consecutively during PWM signal output of the paper separation.

Short Circuit

  • Turn the main power off/on.

  • Replace the board.

  • Check the connector connection.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC498-00

C

Temp Humid Sensor error

  • Temperature Sensor output error: Out of range between 076 V and 2.90 V

  • Humidity Sensor output error: 2.4 V or more

  • Unmounted Sensor (Unset connector or broken wire)

  • Failed Sensor

  • Check that the connector is set.

  • Replace the Sensor.