Skip header
 

SC300 (Image Processing – 1)

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC302-00

D

High voltage output error: Charge unit /Development unit

This SC is issued if the engine board detects a short in the power pack 10 times consecutively.

Open circuit (+) / Short circuit (-)

  • Turn the main power off/on.

  • Replace the board.

  • Check the connector connection.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC332-00

D

Toner supply transfer lock

This SC is issued if the error that the toner is not supplied is detected n times consecutively (n: SP2-931-005) on the condition that the toner cartridge is not in end

  • Overload on the toner transferring part (clogging of toner)

  • Screw for detecting PCDU does not turn

  • Detector element (sensor) defective: light leak

  • Supplying pick does not engage

  • Defective Supplying clutch

  • Defective Drive mechanism of screw for supplying toner cartridge

  • Turn the main power off/on.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC364-00

D

Toner End Sensor output count error

When the average value of the toner end sensor output count is 0 n times consecutively (n: SP2-931-003)

  • Connector contact failure/disconnected/broken

  • Detector element (sensor) does not emit light

  • Detecting surface inside the developing device is stained

  • Turn the main power off/on.