SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC230-00 |
D |
FGATE*1: Does not turn ON. |
GPIO*2 has not been asserted, although the specified time (200 ms) elapsed after setting JOB to be started and reaching the FGAT assert time. |
||
Control Board |
||
Turn the main power off/on. |
(*1)FGATE: Signals used between the controller and the engine in order to send the information about the sub scan length of the page to be printed.
(*2)GPIO: A type of input/output terminal
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC231-00 |
D |
FGATE*1: Does not turn OFF. |
GPIO*2 has not been negated, although the specified time (200 ms) elapsed after detecting GPIO*assert and then reaching the expected FGATE negate time. |
||
* This is an I/O pin. Such I/O pins can be used for a variety of applications, depending on the setting. |
||
|
(*1)FGATE: Signals used between the controller and the engine in order to send the information about the sub scan length of the page to be printed.
(*2)GPIO: A type of input/output terminal
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC270-00 |
D |
Write ASIC communication error |
|
||
The unique ID of the write ASIC was not read normally. |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC277-00 |
D |
LEDA communication error |
The head type data was read three times in succession |
||
|
||
|
||
SC277-10 |
D |
LEDA communication error: other |
The head type data was read three times in succession |
||
|
||
|