Top Page > Main Chapters > Troubleshooting > Service Call 303-396 > SC300 (Engine: Imaging 2: Around the Drum)
SC No. |
Type |
Error Name/Error Condition/Major Cause/Solution |
SC396-01 |
D |
Drum Motor Error 1 |
The drum motor is not stabilized within 2 seconds after the motor is activated. |
|
Connector disconnected or defective Reconnect the following connector. Then perform a conduction inspection. If there is no conduction, replace the connector.
Drive transmission of the drum motor defective Check the gears. If any gears are damaged, replace them.
Drum motor defective Replace the drum motor.
IOB defective Replace the IOB.
|
SC No. |
Type |
Error Name/Error Condition/Major Cause/Solution |
SC396-02 |
D |
Drum Motor Error 2 |
After the drum motor is stabilized, the stable OFF signal is detected for 2 seconds consecutively. |
|
Connector disconnected or defective Reconnect the following connector. Then perform a conduction inspection. If there is no conduction, replace the connector.
Drive transmission of the drum motor defective Check the gears. If any gears are damaged, replace them.
Drum motor defective Replace the drum motor.
IOB defective Replace the IOB.
|