SC300 (Engine: Imaging 2: Around the Drum)

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC396-01

D

Drum Motor Error 1

The drum motor is not stabilized within 2 seconds after the motor is activated.

  • Connector disconnected or defective

  • Drive transmission of the drum motor defective

  • Drum motor defective

  • IOB defective

  • Connector disconnected or defective

    Reconnect the following connector. Then perform a conduction inspection. If there is no conduction, replace the connector.

    • IOB – Drum Motor connector

  • Drive transmission of the drum motor defective

    Check the gears. If any gears are damaged, replace them.

  • Drum motor defective

    Replace the drum motor.

  • IOB defective

    Replace the IOB.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC396-02

D

Drum Motor Error 2

After the drum motor is stabilized, the stable OFF signal is detected for 2 seconds consecutively.

  • Connector disconnected or defective

  • Drive transmission of the drum motor defective

  • Drum motor defective

  • IOB defective

  • Connector disconnected or defective

    Reconnect the following connector. Then perform a conduction inspection. If there is no conduction, replace the connector.

    • IOB – Drum Motor connector

  • Drive transmission of the drum motor defective

    Check the gears. If any gears are damaged, replace them.

  • Drum motor defective

    Replace the drum motor.

  • IOB defective

    Replace the IOB.