Top Page > Main Chapters > Troubleshooting > Service Call 303-396 > SC300 (Engine: Imaging 1: Charge, Development)
SC No. |
Type |
Error Name/Error Condition/Major Cause/Solution |
SC303-00 |
D |
Charger Current Error |
When the charging voltage is applied by changing the voltage in three levels, the current value is less than 20uA in one of three levels. |
|
Connector defective or disconnected Reconnect the following connectors. Then perform a conduction inspection. If there is no conduction, replace the connector.
Power pack defective Replace the power pack.
IOB defective Replace the IOB.
|
SC No. |
Type |
Error Name/Error Condition/Major Cause/Solution |
SC321-00 |
C |
Development Unit Non-Installing Error |
The sensor output value is 31 or less continuously for 5 seconds. |
Connector defective or disconnected
Toner density sensor defective
Connect-Left PCB defective
IOB defective
|
Connector defective or disconnected Reconnect the following connectors. Then perform a conduction inspection. If there is no conduction, replace the connector.
Development Unit – Drum PCB connector
Drum PCB – Drum Connection PCB connector
Drum Connection PCB – Connect-Left PCB connector
Connect-Left PCB – IOB connector
Toner density sensor defective Replace the toner density sensor.
Connect-Left PCB defective Replace the Connect-Left PCB.
IOB defective Replace the IOB.
|