Check the counter of PM parts around the drum and then replace parts for which the counter has been exceeded.
In Adjustment Settings for Skilled Operators > 0201: [Adjust Image Density/ DEMS], execute [Image Density Adjustment: Manual Execute] (SP3-011-002).
Print the image.
Is the printed image acceptable?
Yes: Finish
No: Go to next step
In 0515: [Execute Developer Refreshing], execute [Cyan, Magenta, Yellow], [Black] (SP3-062-001).
Print the image.
Is the printed image acceptable?
Yes: Finish
No: Go to next step.
In 0510: [Temperature / Humidity outside the Machine] (SP3-260-003), check the temperature and humidity around the machine.
Does the value of 0510 show a high temperature, high humidity environment of 27°C and 80% (guidelines) humidity or higher?
*For SP3-260-003, is the value 17 or higher?
Yes: Go to next step.
No: No further improvement can be expected in the field.
Increase the current value of 0209: [Adjust PCU Potential] by +1.
Print the image.
Is the printed image acceptable?
Yes: Finish
No: Go to step 13. (Continue increasing by +1 until the maximum value is reached.)