Top Page > SC Codes > Service Call 700-740 > SC700 (Engine: Peripherals) > Multi-Folding Unit
Multi-Folding Unit
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-01 |
D |
Downstream device communication error |
|
Downstream device break continued even after 10 sec passes.
Partner terminal does not break even 200 msec after the downstream device starts to wait.
ATN without break is received in advance from the downstream device.
ST2 is received from the downstream device during receipt of ST1 frame, or vice versa.
When the response (ACKn) to the frame sent to the downstream device is not notified within the time limit (100 msec), frame sending is retried a maximum of 3 times but there is still no responses acquired.
After connection with the downstream device, the downstream device breaks again.
|
|
|
|
Replace the interface cable.
Replace the PCB of downstream device.
Replace the controller board.
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-03 |
D |
Multi-Folding Unit: Protection device break error 1 |
A fuse has blown on the 24V1 line. |
24V2 line fuse blown |
Replace the Main Board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-04 |
D |
Multi-Folding Unit: Protection device break error 2 |
A fuse has blown on the 24V2 line. |
24V2 line fuse blown |
Replace the Main Board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-12 |
B |
Registration Roller Transport Motor Error |
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-13 |
B |
Dynamic Roller Transport Motor Error |
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-14 |
B |
Top Tray Exit Motor Error |
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-30 |
B |
Stopper 1 Motor Error |
When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-31 |
B |
Stopper 2 Motor Error |
When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-32 |
B |
Stopper 3 Motor Error |
When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-33 |
B |
Jogger Fence Motor Error |
When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-34 |
B |
Dynamic Roller Lift Motor Error |
When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-35 |
B |
Registration Roller Release Motor Error |
When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-36 |
B |
Direct-Send JG Motor Error |
When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-37 |
B |
FM6 Pawl Motor Error |
When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-38 |
B |
Fold Plate Motor Error |
When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
|
|
Replace the Main Board.
Replace the Fold Plate Motor.
Replace the harness.
Re-connect the connector.
Replace the Fold Plate HP Sensor.
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-39 |
B |
1st Fold Motor Error |
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-40 |
B |
2nd Fold Motor Error |
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-41 |
B |
Crease Motor Error |
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-71 |
D |
Horizontal Transport Motor Error |
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-72 |
D |
Horizontal Exit Motor Error |
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-73 |
D |
Top Tray Transport Motor Error |
|
|
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
SC725-74 |
D |
Entrance JG Motor Error |
When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)
Motor driver detected an error. (SC from the first time)
|
|
Replace the Main Board.
Replace the Entrance JG Motor
Replace the harness.
Re-connect the connector.
Replace the Entrance JG HP Sensor.
|