Skip header
 

Multi-Folding Unit

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-01

D

Downstream device communication error


  • Downstream device break continued even after 10 sec passes.

  • Partner terminal does not break even 200 msec after the downstream device starts to wait.

  • ATN without break is received in advance from the downstream device.

  • ST2 is received from the downstream device during receipt of ST1 frame, or vice versa.

  • When the response (ACKn) to the frame sent to the downstream device is not notified within the time limit (100 msec), frame sending is retried a maximum of 3 times but there is still no responses acquired.

  • After connection with the downstream device, the downstream device breaks again.


  • Interface cable (downstream device side) connector disconnected or broken

  • PCB of downstream device defective

  • Controller PCB defective


  • Replace the interface cable.

  • Replace the PCB of downstream device.

  • Replace the controller board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-03

D

Multi-Folding Unit: Protection device break error 1

A fuse has blown on the 24V1 line.

24V2 line fuse blown

Replace the Main Board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-04

D

Multi-Folding Unit: Protection device break error 2

A fuse has blown on the 24V2 line.

24V2 line fuse blown

Replace the Main Board.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-12

B

Registration Roller Transport Motor Error

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Replace the Main Board.

  • Replace the Registration Roller Transport Motor.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-13

B

Dynamic Roller Transport Motor Error

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Replace the Main Board.

  • Replace the Dynamic Roller Transport Motor

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-14

B

Top Tray Exit Motor Error

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Replace the Main Board.

  • Replace the Top Tray Exit Motor.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-30

B

Stopper 1 Motor Error

  • When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)

  • When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Connector disconnected

  • Replace the Main Board.

  • Replace the Stopper 1 Motor.

  • Replace the harness.

  • Reconnect the connector.

  • Replace the Stopper 1 HP Sensor

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-31

B

Stopper 2 Motor Error

  • When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)

  • When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Connector disconnected

  • Replace the Main Board.

  • Replace the Stopper 2 Motor.

  • Replace the harness.

  • Reconnect the connector.

  • Replace the Stopper 2 HP Sensor.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-32

B

Stopper 3 Motor Error

  • When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)

  • When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Connector disconnected

  • Replace the Main Board.

  • Replace the Stopper 3 Motor.

  • Replace the harness.

  • Reconnect the connector.

  • Replace the Stopper 3 HP Sensor.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-33

B

Jogger Fence Motor Error

  • When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)

  • When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Connector disconnected

  • Replace the Main Board.

  • Replace the Jogger Fence Motor.

  • Replace the harness.

  • Reconnect the connector.

  • Replace the Jogger Fence HP Sensor.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-34

B

Dynamic Roller Lift Motor Error

  • When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)

  • When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Connector disconnected

  • Replace the Main Board.

  • Replace the Dynamic Roller Lift Motor

  • Replace the harness.

  • Reconnect the connector.

  • Replace the Dynamic Roller HP Sensor.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-35

B

Registration Roller Release Motor Error

  • When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)

  • When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Connector disconnected

  • Replace the Main Board.

  • Replace the Registration Roller Release Motor.

  • Replace the harness.

  • Reconnect the connector.

  • Replace the Jogger Fence HP Sensor.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-36

B

Direct-Send JG Motor Error

  • When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)

  • When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Connector disconnected

  • Replace the Main Board.

  • Replace the Direct-Send JG Motor.

  • Replace the harness.

  • Reconnect the connector.

  • Replace the Direct Send JG HP Sensor.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-37

B

FM6 Pawl Motor Error

  • When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)

  • When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Connector disconnected

  • Replace the Main Board.

  • Replace the FM6 Pawl Motor.

  • Replace the harness.

  • Reconnect the connector.

  • Replace the Bypass Exit Paper Sensor.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-38

B

Fold Plate Motor Error

  • When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)

  • When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Connector disconnected

  • Replace the Main Board.

  • Replace the Fold Plate Motor.

  • Replace the harness.

  • Re-connect the connector.

  • Replace the Fold Plate HP Sensor.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-39

B

1st Fold Motor Error

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Replace the Main Board.

  • Replace the 1st Fold Motor.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-40

B

2nd Fold Motor Error

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Replace the Main Board.

  • Replace the 2nd Fold Motor

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-41

B

Crease Motor Error

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Replace the Main Board.

  • Replace the Crease Motor.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-71

D

Horizontal Transport Motor Error

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Replace the Main Board.

  • Replace the Horizontal Transport Motor

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-72

D

Horizontal Exit Motor Error

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Replace the Main Board.

  • Replace the Horizontal Exit Motor.

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-73

D

Top Tray Transport Motor Error

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Replace the Main Board.

  • Replace the Top Tray Transport Motor

  • Replace the harness.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC725-74

D

Entrance JG Motor Error

  • When moving to the home position, home position was not detected within specified number of pulses. (The first time: jam display, the second time: SC)

  • When moving from the home position, home position was still detected after specified number of pulses. (The first time: jam display, the second time: SC)

  • Motor driver detected an error. (SC from the first time)

  • Overcurrent to the motor.

  • Motor drive overheat

  • Connector disconnected

  • Replace the Main Board.

  • Replace the Entrance JG Motor

  • Replace the harness.

  • Re-connect the connector.

  • Replace the Entrance JG HP Sensor.