SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC700-01 |
D |
Bottom plate lift motor error (1-pass ADF) |
The bottom plate HP sensor does not detect the home position of the bottom plate after the bottom plate lift motor switches on and lowers the bottom plate. Or, the bottom plate position sensor does not detect the position of the plate after the lift motor switches on and raises the bottom plate. Details: The ADF notifies the main machine of the error. The first two occurrences are displayed as jams. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC700-02 |
D |
Original pick up error (1-pass ADF) |
ADF Feed Motor is turned on but the Pickup Roller HP Sensor is not detecting it. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC700-04 |
D |
Entrance Motor error (1-pass ADF) |
Error signal detected while the motor is driven. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC700-05 |
D |
Pickup Roller Motor error (1-pass ADF) |
Error signal detected while the motor is driven. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC700-06 |
D |
Transport Motor error (1-pass ADF) |
Error signal detected while the motor is driven. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC700-07 |
D |
Scan Motor error (1-pass ADF) |
Error signal detected while the motor is driven. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC700-09 |
D |
Exit Motor error (1-pass ADF) |
Error signal detected while the motor is driven. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC701-02 |
D |
Original pick-up motor driver error (1-pass ADF) |
Motor driver IC error flag was asserted when a jam occurred. |
||
Motor driver IC detected an error. |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC702-04 |
D |
Protection device break error 4 (1-pass ADF) |
The non-interlock power supply system protection device broke the circuit with the 24V power supply on. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC702-05 |
D |
Protection device break error 5 (1-pass ADF) |
The non-interlock power supply system protection device broke the circuit with the 24V power supply on. |
||
|
||
|