SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC816-00 |
[0x0000] |
Energy save I/O subsystem error |
SC816-01 |
D |
Subsystem error |
SC816-02 |
D |
Sysarch (LPUX_GET_PORT_INFO) error |
SC816-03 |
D |
Transition to STR was denied. |
SC816-04 |
D |
Interrupt in kernel communication driver |
SC816-05, 06 |
D |
Preparation for transition to STR failed. |
SC816-07 |
D |
Sysarch (LPUX_GET_PORT_INFO) error |
SC816-08 |
D |
Sysarch (LPUX_ENGINE_TIMERCTRL) error |
SC816-09 |
D |
Sysarch (LPUX_RETURN_FACTOR_STR) error |
SC816-10 |
D |
Sysarch (LPUX_GET_PORT_INFO) error |
SC816-11 |
D |
Sysarch (LPUX_GET_PORT_INFO) error |
SC816-12 |
D |
Sysarch (LPUX_GET_PORT_INFO) error |
SC816-13 |
D |
open() error |
SC816-14 |
D |
Memory address error |
SC816-15 |
D |
open() error |
SC816-16 |
D |
open() error |
SC816-17 |
D |
open() error |
SC816-18 |
D |
open() error |
SC816-19 |
D |
Double open() error |
SC816-20 |
D |
open() error |
SC816-22 |
D |
Parameter error |
SC816-23 |
D |
read() error |
SC816-24 |
D |
read() error |
SC816-25 |
D |
read() error |
SC816-26 |
D |
write() communication retry error |
SC816-27 |
D |
write() communication retry error |
SC816-28 |
D |
write() communication retry error |
SC816-29 |
D |
write() communication retry error |
SC816-30 |
D |
write() communication retry error |
SC816-35 |
D |
read() error |
SC816-36 to94 |
D |
Subsystem error |
Energy save I/O subsystem detected some abnormality. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC818-00 |
D |
Watchdog timer error |
|
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC819-00 |
D |
Fatal kernel error [XXXX]: Detailed error code |
Due to a control error, a RAM overflow occurred during system processing. One of the following messages was displayed on the operation panel. |
||
|
||
Replace controller firmware |
||
[0x5032] |
HAIC-P2 error |
|
HAIC-P2 decompression error (An error occurred in the ASIC compression/decompression module.) |
||
[0x6261] |
HDD defective |
|
6261 6420 6469 7200 00 |
||
[0x696e] |
gwinit process ending |
|
x69742064 |
||
[0x766d] |
VM is full |
|
0x5f706167 |
||
---- |
Others |
|
Error in the OS |
||
Others |
||
"init died", "vm_pageout: VM is full", "Cache Error” |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC820-00 |
D |
Self-diagnostics error: CPU [XXXX]: Detailed error code |
[0001] to [06FF] [0801] to [4005] |
CPU error During the self-diagnosis, the controller CPU detects an error. There are 47 types of error code (0001 to 4005) depending on the cause of the error. The CPU detects an error and displays the specific error code with the program address where the error occurs. |
|
|
||
1. Turn the main power off/on. 2. Reinstall the controller system firmware. 3. Replace the controller. When the problem cannot be fixed with the above procedure, the following information displayed on the screen needs to be reported to the technical support center. - SC code - Detailed error code - Program address |
||
[0701] to [070A] |
CPU/Memory Error |
|
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC821-00 |
D |
Self-diagnostics error: ASIC [XXXX]: Detailed error code |
[0B00] |
ASIC register check error |
|
The write-&-verify check has occurred in the ASIC. |
||
Defective ASIC device |
||
Replace the controller board. |
||
[0B06] |
ASIC detection error |
|
The I/O ASIC for system control is not detected. |
||
|
||
Replace the controller board. |
||
[50A2] |
Video bridge device (ASIC) register error 1 |
|
The CPU detects the video bridge device, but detects error data from the video bridge device. |
||
Defective I/F between the video bridge device and controller |
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC823-00 |
B |
Self-diagnostics error: NIC [XXXX]: Detailed error code |
[6101] |
MAC address check sum error |
|
The result of the MAC address check sum does not match the check sum stored in ROM. |
||
|
||
Replace the controller board. |
||
[6104] |
PHY IC error |
|
The PHY IC on the controller cannot be correctly recognized. |
||
|
||
Replace the controller board. |
||
[6105] |
PHY IC loop-back error |
|
An error occurred during the loop-back test for the PHY IC on the controller. |
||
|
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC824-00 |
D |
Self-diagnostics error: NVRAM (resident) [XXXX]: Detailed error code |
[1401] |
NVRAM verify error |
|
NVRAM device is missing or NVRAM device is damaged. |
||
|
||
Replace the NVRAM device. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC827-00 |
D |
Self-diagnostic error: Standard SDRAM DIMM [XXXX]: Detailed error code |
[0201] |
Verification error |
|
Error detected during a write/verify check for the standard RAM (SDRAM DIMM). |
||
|
||
[0202] |
Resident memory error |
|
The SPD values in all RAM DIMM are incorrect or unreadable. |
||
|
||
Replace the RAM DIMM. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC828-00 |
D |
Self-diagnostic error: ROM [XXXX]: Detailed error code |
[0101] |
Check sum error 1 |
|
The boot monitor and OS program stored in the ROM DIMM is checked. If the check sum of the program is incorrect, this SC code is displayed. |
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC829-00 |
D |
Self-diagnostic error: Optional RAM [XXXX]: Detailed error code |
[0301] [0401] |
Verification error (Optional RAM slot ) |
|
Error detected during a write/verify check for the optional RAM (SDRAM DIMM). |
||
|
||
|
||
[0302] [0402] |
Memory structure data error (Optional RAM slot ) |
|
The memory structure data error for the optional RAM (SDRAM DIMM) is detected during self-diagnosis. |
||
|
||
Replace the RAM DIMM. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC835-00 |
B |
Self-diagnostic error: Standard SDRAM DIMM [XXXX]: Detailed error code |
[1102] |
The loopback connector is connected but check results is an error. |
|
|
||
Replace the controller board. |
||
[110C] |
The loopback connector is connected but check results is an error. |
|
|
||
Replace the controller board. |
||
[1120] |
Centronic loopback connector is not connected for detailed self-diagnostic test. |
|
|
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC838-00 |
D |
Self-diagnostic Error: Clock Generator [XXXX]: Detailed error code |
[2701] |
A verify error occurred when setting data was read from the clock generator via the I2C bus. |
|
|
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC839-00 |
D |
Self-diagnostic Error: Serial Flash [XXXX]: Detailed error code |
[9001] |
USB NAND Flash ROM cannot be read. |
|
Defective controller board |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC840-00 |
D |
EEPROM access error |
While executing I/O to the EEPROM, an error is detected:
|
||
EEPROM is defective or has reached its end of life. |
||
- |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC841-00 |
D |
Error in data read from the EEPROM |
When mirrored data read from three different regions in the EEPROM differ each other. |
||
For some reason, the data stored in a particular region of the EEPROM has been overwritten. |
||
- |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC842-00 |
C |
Verification error in the NAND-Flash update |
When updating the remote ROM and the ROM, SCS encountered an error in writing to the NAND-Flash memory that holds the module data. |
||
Defective NAND-Flash memory. |
||
Turn the main power off/on. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC842-01 |
B |
Verification error during NAND-Flash update |
When starting-up the machine or re-stating it from the energy saving, the machine reads the state of the NAND-Flash and detects that there are defective blocks whose amount exceeds the threshold. This means that the life of the NAND-Flash is near-end. |
||
Near-end Life of NAND-Flash |
||
Replace the controller board as soon as possible. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC842-02 |
B |
NAND-Flash Block-deletion Excess-error |
When starting-up the machine or re-starting it from the energy saving, the machine reads the state of the NAND-Flash and detects that there are block-deletions whose amount exceeds the threshold. This means that the life of the NAND-Flash is near-end. |
||
Near-end Life of NAND-Flash |
||
Replace the controller board as soon as possible. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC853-00 |
B |
Bluetooth device connection error |
When a Bluetooth hardware device (USB type) is connected after startup. |
||
A Bluetooth hardware device (USB type) has been connected after startup. |
||
Connect the Bluetooth hardware device (USB type) before turning on the main power. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC854-00 |
B |
Bluetooth device removal error |
When a Bluetooth hardware device (USB type) is removed after startup. |
||
A Bluetooth hardware device (USB type) has been removed after startup. |
||
Connect the Bluetooth hardware device (USB type) before turning on the main power. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC855-01 |
B |
Wireless LAN board error (driver attachment failure) |
Wireless LAN board error (wireless LAN card: 802.11 is covered) |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC855-02 |
B |
Wireless LAN board error (driver initialization failure) |
Wireless LAN board error (wireless LAN card: 802.11 is covered) |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC857-00 |
B |
USB driver error |
USB I/F is not available due to USB driver error. |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC858-00 |
A |
Data encryption conversion error (Key error) |
A serious error occurred during an attempt to update the encryption key. |
||
|
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC858-01 |
A |
Data encryption conversion error (HDD Key Setting Error) |
A serious error occurred during an attempt to update the encryption key. |
||
|
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC858-02 |
A |
Data encryption conversion error (NVRAM read/write error) |
A serious error occurred after data conversion during an attempt to update the encryption key. |
||
NVRAM is defective |
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC858-30 |
A |
Data encryption conversion error (NVRAM Before Replace error) |
A serious error occurred after data conversion during an attempt to update the encryption key. |
||
Software error such as conversion parameters being invalid. |
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC858-31 |
A |
Data encryption conversion error (Other Error) |
A serious error occurred after data conversion during an attempt to update the encryption key. |
||
Controller board is defective. |
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC859-01 |
B |
Data encryption conversion HDD conversion error (HDD check error) |
HDD was not converted correctly during an attempt to update the encryption key. Only an error screen is displayed and no SC is issued during conversion. This SC is issued after machine restarts. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC859-02 |
B |
Data encryption conversion HDD conversion error (Power failure during conversion) |
HDD was not converted correctly during an attempt to update the encryption key. Only an error screen is displayed and no SC is issued during conversion. This SC is issued after machine restarts. Details: NVRAM/HDD conversion is incomplete. |
||
Power failure occurred during encryption key update. |
||
None The display after the restarting instructs the user to format the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC859-10 |
B |
Data encryption conversion HDD conversion error (Data read/write command error) |
HDD was not converted correctly during an attempt to update the encryption key. Only an error screen is displayed and no SC is issued during conversion. This SC is issued after machine restarts. Details: Abnormal DMAC return value has been received two or more times (DMAC timeout, serial communication error etc.) |
||
HDD was not successfully converted during encryption key update due to HDD errors or cable noises. |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC860-00 |
B |
Hard disk startup error at power-on |
A hard disk is connected, but the driver detected the following errors: SS_NOT_READY (-2) The HDD is not ready. SS_BAD_LABEL (-4) Incorrect partition type. SS_READ_ERROR (-5) An error occurred while reading or checking labels. SS_WRITE_ERROR (-6) An error occurred while writing or checking labels. SS_FS_ERROR (-7) Failed to restore filesystem. SS_MOUNT_ERROR (-8)Failed to mount filesystem. SS_COMMAND_ERROR (-9) The driver does not respond to the command. SS_KERNEL_ERROR (-10) Internal kernel error. SS_SIZE_ERROR: (-11)The drive is too small. SS_NO_PARTITION: (-12) The specified partition does not exist. SS_NO_FILE No device file exists. Tried to obtain the information about the status of the hard disk from the driver, but no response has been returned for more than 30 seconds. |
||
|
||
Initialize the hard disk from SP mode. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-01 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in an area that does not belong to a partition, such as the disklabel area.) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-02 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "a".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-03 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "b".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-04 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "c".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-05 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "d".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-06 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "e".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-07 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "f".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-08 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "g".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-09 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "h".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-10 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "i".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-11 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "j".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-12 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "k".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-13 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "l".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-14 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "m".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-15 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "n".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-16 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "o".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-17 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "p".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-18 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "q".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-19 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "r".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-20 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "s".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-21 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "t".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-22 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "u".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC863-23 |
D |
HDD data read failure |
The data written to the HDD cannot be read normally. |
||
Bad sectors were generated during operation. (An error occurred in partition "v".) |
||
Guide for when to replace the HDD
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-00 |
D |
HDD data CRC error |
While reading data from the HDD or storing data in the HDD, data transmission fails. |
||
Defective HDD |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-01 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in an area that does not belong to a partition, such as the disklabel area.) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-02 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "a".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-03 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "b".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-04 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "c".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-05 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "d".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-06 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "e".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-07 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "f".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-08 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "g".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-09 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "h".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-10 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "i".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-11 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "j".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-12 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "k".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-13 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "l".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-14 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "m".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-15 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "n".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-16 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "o".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-17 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "p".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-18 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "q".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-19 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "r".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-20 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "s".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-21 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "t".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-22 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "u".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC864-23 |
D |
HDD data CRC error |
During HDD operation, the HDD returned a CRC error. |
||
Bad sectors were generated during operation. (An error occurred in partition "v".) |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-00 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-01 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in an area that does not belong to a partition, such as the disklabel area.) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-02 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "a".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-03 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "b".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-04 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "c".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-05 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "d".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-06 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "e".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-07 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "f".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-08 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "g".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-09 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "h".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-10 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "i".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-11 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "j".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-12 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "k".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-13 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "l".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-14 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "m".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-15 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "n".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-16 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "o".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-17 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "p".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-18 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "q".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-19 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "r".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-20 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "s".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-21 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "t".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-22 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "u".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-23 |
D |
HDD access error |
During HDD operation, the HDD returned an error. |
||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "v".) |
||
Replace the HDD. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC866-00 |
B |
SD card authentication error |
When a correct license for digital authentication is not found in an SD card application. |
||
The SD card contains the wrong program data. |
||
Store the correct program data on the SD card. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC867-00 |
D |
SD card removal detection |
When an application SD card is removed from the slot while the application is being activated. |
||
An application SD card has been removed from the slot (from the mount point /mnt/sd0). |
||
Turn the main power off/on. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC867-01 |
D |
SD card removal detection |
When an application SD card is removed from the slot while the application is being activated. |
||
An application SD card has been removed from the slot (from the mount point /mnt/sd1). |
||
Turn the main power off/on. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC868-00 |
D |
SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd0) |
||
|
||
|
* Do not format the SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by the Customer Engineer.
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC868-01 |
D |
SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd1) |
||
|
||
SD card used for starting an application
|
* Do not format the SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by the Customer Engineer.
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC870-00 |
B |
Address Book data error (Anytime: Address Book Error.) |
SC870-01 |
B |
Address Book data error (On startup: Media required for storing the Address Book is missing.) |
SC870-02 |
B |
Address Book data error (On startup: encryption is configured but the module required for encryption (DESS) is missing.) |
SC870-03 |
B |
Address Book data error (Initialization: Failed to generate a file to store internal Address Book.) |
SC870-04 |
B |
Address Book data error (Initialization: Failed to generate a file to store delivery sender.) |
SC870-05 |
B |
Address Book data error (Initialization: Failed to generate a file to store delivery destination.) |
SC870-06 |
B |
Address Book data error (Initialization: Failed to generate a file to store information required for LDAP search.) |
SC870-07 |
B |
Address Book data error (Initialization: Failed to initialize entries required for machine operation.) |
SC870-08 |
B |
Address Book data error (Machine configuration: HDD is present but the space for storing the Address Book is unusable.) |
SC870-09 |
B |
Address Book data error (Machine configuration: Inconsistency in the NVRAM area used for storing settings required for Address Book configuration.) |
SC870-10 |
B |
Address Book data error (Machine configuration: Cannot make a directory for storing the Address Book in the SD/USB FlashROM.) |
SC870-11 |
B |
Address Book data error (On startup: Inconsistency in Address Book entry number.) |
SC870-20 |
B |
Address Book data error (File I/O: Failed to initialize file.) |
SC870-21 |
B |
Address Book data error (File I/O: Failed to generate file.) |
SC870-22 |
B |
Address Book data error (File I/O: Failed to open file.) |
SC870-23 |
B |
Address Book data error (File I/O: Failed to write to file.) |
SC870-24 |
B |
Address Book data error (File I/O: Failed to read file.) |
SC870-25 |
B |
Address Book data error (File I/O: Failed to check file size.) |
SC870-26 |
B |
Address Book data error (File I/O: Failed to delete data.) |
SC870-27 |
B |
Address Book data error (File I/O: Failed to add data.) |
SC870-30 |
B |
Address Book data error (Search: Failed to obtain data from cache when searching in the machine Address Book. delivery destination/sender.) |
SC870-31 |
B |
Address Book data error (Search: Failed to obtain data from cache during LDAP search.) |
SC870-41 |
B |
Address Book data error (Cache: failed to obtain data from cache.) |
SC870-50 |
B |
Address Book data error (On startup: Detected abnormality of the Address Book encryption status.) |
SC870-51 |
B |
Address Book data error (Encryption settings: Failed to create directory required for conversion between plaintext and encrypted text.) |
SC870-52 |
B |
Address Book data error (Encryption settings: Failed to convert from plaintext to encrypted text.) |
SC870-53 |
B |
Address Book data error (Encryption settings: Failed to convert from encrypted text to plaintext.) |
SC870-54 |
B |
Address Book data error (Encryption settings: Detected data inconsistency when reading the encrypted Address Book.) |
SC870-55 |
B |
Address Book data error (Encryption settings: Failed to delete file when changing encryption setting.) |
SC870-56 |
B |
Address Book data error (Encryption settings: Failed to erase the file that records the encryption key during an attempt to change the encryption setting.) |
SC870-57 |
B |
Address Book data error (Encryption settings: Failed to move a file during an attempt to change the encryption setting.) |
SC870-58 |
B |
Address Book data error (Encryption settings: Failed to delete a directory during an attempt to change the encryption setting.) |
SC870-59 |
B |
Address Book data error (Encryption settings: Detected a resource shortage during an attempt to change the encryption setting.) |
SC870-60 |
B |
Address Book data error (Unable to obtain the on/off setting for administrator authentication (06A and later).) |
When an error related to the Address Book is detected during startup or operation. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC872-00 |
B |
HDD mail received data error |
An error is detected in the HDD at machine power-on. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC873-00 |
B |
HDD mail transfer error |
An error is detected in the HDD at machine power-on. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC874-05 |
D |
Delete All Error (Delete data area): Read Error |
SC874-06 |
D |
Delete All Error (Delete data area): Write Error |
SC874-09 |
D |
Delete All Error (Delete data area): Drive No Response |
SC874-10 |
D |
Delete All Error (Delete data area): Kernel Error |
SC874-12 |
D |
Delete All Error (Delete data area): No Specific Partition |
SC874-13 |
D |
Delete All Error (Delete data area): No Device File |
SC874-14 |
D |
Delete All Error (Delete data area): Incorrect Boot Option |
SC874-15 |
D |
Delete All Error (Delete data area): No Specific Sector |
SC874-16 |
D |
Delete All Error (Delete data area): hdderase Execution Error |
SC874-41 |
D |
Delete All Error (Delete data area): Other Fatal Error |
SC874-42 |
D |
Delete All Error (Delete data area): Abort |
SC874-61 to -65 |
D |
Delete All Error (Delete data area): Incorrect Return Value: Libraly |
SC874-66 |
D |
Delete All Error (Delete data area): Not Abailable |
SC874-67 |
D |
Delete All Error (Delete data area): Delete Not End |
SC874-68 |
D |
Delete All Error (Delete data area): HDD Format Failure (Normal) |
SC874-69 |
D |
Delete All Error (Delete data area): HDD Format Failure (Error) |
SC874-70 |
D |
Delete All Error (Delete data area): Incorrect Return Value: Libraly |
SC874-99 |
D |
Delete All Error (Delete data area): Other Error |
An error regarding data erase is detected. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC875-** |
D |
Delete All error (HDD) |
An error is detected before executing HDD Erase. |
||
875-01
875-02
|
||
Turn the main power off/on. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-01 |
D |
Log Data Error 1 |
An error was detected in the acquisition or configuration of the log data at power on or during machine operation. |
||
Damaged log data file |
||
Initialize the HDD (SP5-832-004). |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-02 |
D |
Log Data Error 2 |
An error was detected in the acquisition or configuration of the log data at power on or during machine operation. |
||
Log encryption is enabled but encryption module is not installed. |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-03 |
D |
Log Data Error 3 |
An error was detected in the acquisition or configuration of the log data at power on or during machine operation. |
||
Inconsistency of encryption key between NVRAM and HDD. |
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-04 |
D |
Log Data Error 4 |
An error was detected in the acquisition or configuration of the log data at power on or during machine operation. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-05 |
D |
Log Data Error 5 |
An error was detected in the acquisition or configuration of the log data at power on or during machine operation. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-99 |
D |
Log Data Error 99 |
An error was detected in the acquisition or configuration of the log data at power on or during machine operation. |
||
Other causes |
||
- |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC877-00 |
B |
Data Overwrite Security card error |
The "Auto Erase Memory" function of the Data Overwrite Security is enabled but it cannot be executed. |
||
|
||
|
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC878-00 |
D |
TPM electronic authentication error |
The machine failed TPM electronic authentication. System hash registered in the TPM did not match the data on the USB flash. |
||
|
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC878-01 |
D |
USB Flash error |
USB Flash file system error |
||
USB Flash file system has been destroyed. |
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC878-02 |
D |
TPM error |
An error occurred in the TPM or TPM driver. |
||
TPM is defective |
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC878-03 |
D |
TCSD error |
An error occurred in TPM software stack. |
||
|
||
Replace the controller board. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC881-01 |
D |
Management area error |
Defective software has been detected. |
||
Abnormal accumulation of authentication information in the software |
||
Turn the main power off/on. |
SC No. |
Level |
Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC899-00 |
D |
Software performance error (signal reception end) |
- |
||
Occurs when an internal program behaves abnormally. |
||
In case of a hardware defect
In case of a software error
|