SC900 (Controller)

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC900-00

A

Electric counter error

The electric total counter value is out of specification.

Error is detected when increasing the total counter.

  • Unexpected NV-RAM is attached.

  • NV-RAM defective

  • NV-RAM data corrupted.

  • Data written to unexpected area because of external factor etc.

  • The count requested by the SRM on receiving PRT is not completed.

Replace the NV-RAM.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC990-00

D

Software operation error

Software attempted an unexpected operation.

  • Parameter error

  • Internal parameter error

  • Insufficient work memory

  • Operation error caused by abnormalities that are normally undetectable.

  • Turn the main power OFF/ON.

  • Reinstall the software of the controller board and BiCU.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC991-00

C

Recoverable software operation error

Software attempted an unexpected operation.

SC991 covers recoverable errors as opposed toCS990.

  • Parameter error

  • Internal parameter error

  • Insufficient work memory

  • Operation error caused by abnormalities that are normally undetectable.

Logging only

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC992-00

D

Undefined SC issued.

An SC, that is not controlled by the system, occurred.

  • An SC for the previous model was used mistakenly, etc.

  • Basically a software bug.

Turn the main power OFF/ON.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC997-00

D

Application function selection error

  • No response to the predetermined command from SCS to the same application program 4 times consecutively.

    Cases when SC997-00 occur;

    1. SCS sends command to the copy application.

    2. There has been no response from the copy application for 30 sec. (Error count value: 1)

    3. Step1-2 is repeatedly performed 3 times. (Error count value: 4)

    4. SC997-00 occur.

Cases when SC997-00 does not occur;

  1. SCS sends command to the copy application.

  2. There has been no response from the copy application for 30 sec. (Error count value: 1)

    Step1-2 is repeatedly performed 2 times. (Error count value: 4)

  3. SCS sends command to the copy application.

    There has been response from the copy application. (Error count value: 1)

  • The application ended by an unusual process.



Software bug (mainly the application)

  • Check the optional RAM/DIMM/boards required by the application program.

  • Check if the combination of downloaded programs are correct.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC998-00

D

Application start error

  • No application was registered to system within a specified time after the main power was turned ON.

    (No application starts/All applications have been terminated abnormally)

  • Application started but cannot be drawn now for some reason.

  • Software bug (mainly the application)

  • The optional RAM/DIMM/boards, required by the application program, are not installed correctly.

  • Check the optional RAM/DIMM/boards required by the application program.

  • Check if the combination of downloaded programs are correct.

  • Replace the controller board.